Nominal voltage: 250 V - 600 V
Temperature: -15 °C - 80 °C
These cables are highly flexible and can be used to drag chains, drum reeling systems, cranes, and many other moving applications. We offer a variety of flexible cables. The cables require ...
Lapp Muller
Temperature: -25 °C - 80 °C
Length: 500, 1, 100 m
UL-approved PUR-Data Transmission- /Control Cables in AWG 22, shielded, zero halogen, flame retardant, with small outer jacket. High flexible stranded copper conductor, closed twisted pairs. number ...
Metrofunk Kabel-Union
Temperature: -25 °C - 80 °C
Length: 500, 1, 100 m
UL-approved PUR-Data Transmission- /Control Cables in AWG 22, shielded, zero halogen, flame retardant, with small outer jacket. High flexible stranded copper conductor, closed twisted pairs. number of ...
Metrofunk Kabel-Union
Temperature: -10 °C - 80 °C
Cross-section: 0.08 mm²
Length: 1, 500, 100 m
Computer Cable with highly flexible stranded wire construction 0,08mm², outer shielding, 2 to 32 pairs, lightgray PVC-jacket. number of cores: 4, 6, 8, 12, 16, 24, 36, 48, 64
Metrofunk Kabel-Union
Nominal voltage: 300 V
Temperature: -25 °C - 80 °C
• Flexible cable suitable for internal wiring of electronic equipment and devices. • Extra-flexible red electrolytic copper conductor • Polypropylene insulation • Polyurethane sheath
PONY SRL
Nominal voltage: 300 V
Temperature: -20 °C - 80 °C
• Flexible cable suitable for internal wiring of electronic equipment and devices. • Flexible tinned electrolytic copper conductor • Semi-rigid PVC insulation ( SRPVC ) • PVC sheath 80°C
PONY SRL
Nominal voltage: 600 V
Temperature: -20 °C - 90 °C
• Flexible cable suitable for internal or external wiring of electronic equipment. • Flexible tinned electrolytic copper conductor • Special PVC insulation with high heat resistance • Special PVC sheath with high heat resistance
PONY SRL
Temperature: -40 °C - 80 °C
Temperature: -40 °C - 80 °C
Cross-section: 0.14, 0.25, 0.5 mm²
Nominal voltage: 300, 500 V
Temperature: -30 °C - 70 °C
Cross-section: 1.75, 1, 0.75 mm²
power, control and connecting cable in electrical facilities, for fixed laying and casually movement without tensile stress and without defined cable routing. Suitable for use in dry, ...
CAE GROUPE
Nominal voltage: 300 V
Temperature: -30 °C - 70 °C
Length: 500 m
CAE GROUPE
Nominal voltage: 600 V - 1,000 V
Temperature: -30 °C - 70 °C
power, control and connecting cable for drive systems with frequency converter technology, for fixed laying and casually movement without tensile stress and without defined cable routing. Suitable for ...
CAE GROUPE
The SS321 by Temperature Technology Ltd. is a mineral insulated and metal sheathed RTD cable. The unit is available with copper or nickel conductors. It is made out of stainless steel ...
Nominal voltage: 500 V
Temperature: -65 °C - 200 °C
1. Centre conductor 2. Dielectric/Insulation 3. Screen/Outer conductor 4. Outer jacket: Conductor DC resistance: Max.344Ω/km Insulation resistance: >100MΩ/km Capacitance: 41pF/m Impedance: Nom 110Ω - core opposite core Weight: ...
With the new PROFINET green cables, BizLink understands the importance of sustainability without comprising performance, and developed two cable types with outer jackets based on plant material. The ...
BizLink Robotic Solutions Germany GmbH
Nominal voltage: 800 V
Temperature: -30 °C - 70 °C
acc. to DIN VDE 0815 For information transmission in dry and moist production sites, in and under plaster, outdoors for fixed installation Not approved for power and underground installation. DIN VDE 0815 ; directive 2014/35/EU RoHS ...
VOKA
Nominal voltage: 100 V
Temperature: -20 °C - 70 °C
Application area: Industrial automation • Electrical Values Cat.5e SF/UTP 100 MHz • Norms ○ DIN EN 50290-2-23 ○ DIN EN 50290-2-21 ○ DIN EN 50290-2-22 • Cable Construction ...
AIXONTEC
Nominal voltage: 300 V
Derul Cable is able to design and manufacture Remotely Operated Vehicle (ROV) tethers. Power & signals are integrated into a cable structure, so ROV tethers can be used to transmit both electricity and ...
Derulcable (Shanghai) Co., Ltd
The GLS leads from hotset can be used at high temperature conditions of over 300 °C – when the use of copper cables is no longer possible. hotset offer a wide range of choice in cross-section, tracer thread and packaging. ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining