- Electricity - Electronics >
- Switch and Relay >
- AC protection relay
AC protection relays
Tripping current: 5 A
Trigger voltage: 250 V
... differential protection and short-circuit protection relay for generator protection against internal short circuits (leaking currents). The MDR-2 is a state-of-the-art ...
DEIF
Tripping current: 5 A
Trigger voltage: 220 V
... connected to one relay. It used to limits damages to equipment, improve safety, avoid and protect personnel injuries. It’s also can be used as a stand-alone arc protection relay or ...
Chongqing Blue Jay Technology Co. Ltd
Tripping current: 300 mA
• Type A – Earth Leakage Relay • Compact dimensions – 17.5mm wide (DIN Rail mount) • True RMS • Fixed Trip level (300mA) and Time delay (0s) • Combined Test and Reset button • 1 x SPDT Relay output This ...
Broyce Control
Tripping current: 6 A
Trigger voltage: 230 V
• thermistor motor protection relay • 5 selectable functions • up to 6 PTC-sensors in series switchable test function (without sensor connected) • probe short and/or open circuit detection automatical, ...
The AC / DC Earth Leakage Unit is a residual current detection unit which is powered from the vehicle’s battery or AC supply and measures the sum of the current in the primary ‘supply and return’ conductors ...
Tripping current: 10 A
Trigger voltage: 250 V
Single and three phase protection Phase failure (loss phase) protection Phase sequence protection Adjustable voltage protection Over voltage and/or low voltage protection Contact ...
... fault recording • 64 sample for cycle measurement for accuracy of protection element COMMUNICATION SECURITY Communication Security through redundancy protocol and Cyber Security ...
THYTRONIC
High speed differential protection for various items of power system plant including generators, busbars, motors & the individual windings of power transformers and for restricted earth fault applications. The MS2V73 ...
Motor Protection Relay The device has been designed for continuous monitoring of electrical parameters in low voltage systems. It allows direct, close-distance or remote monitoring via RS-485 and bluetooth ...
Orion Italia
Trigger voltage: 115 V - 240 V
Tripping current: 30 mA - 30,000 mA
Trigger voltage: 220 V
... leakage current protection relayis used together with LV circuit breaker, tripping coil and toroidal transformer in combination with leakage current protection. The connections that must be made when ...
Trigger voltage: 380 V
Phase Failure Relay Features The phase protection relays are designed to protect the three-phase loads from damage caused by mains voltage. - Asymmetry : ~30%
Tense Electronic
Tripping current: 0.1 A - 150 A
... Wide adjustable current range (5:1) ‧ Phase failure, over current, inrush current, phase unbalance protection ‧ Quick response protection within 3 seconds ‧Adjustable trip class 5/10/20/30 ‧4-in-1 ...
Setting range from 0,3 up to 800 A Direct mounting on contactor or separated with special kit Automatic reset and /or manual
Tripping current: 0.35 A - 160 A
... bimetal type thermal over-load relay is suitable for the circuit of AC 50Hz, rated operating voltage Ue: AC 690V, current of 0.25~160A, as the use of over-load and break phase ...
PEOPLE ELE. APPLIANCE GROUP CO., LTD.
Tripping current: 0 A - 16 A
Trigger voltage: 220 V - 415 V
S91 is a protection device for electric motors. It allows the detection of incorrect phase sequence or phase failure, excess current consumption, no-load operation with power factor measurement. The device has an input ...
Tripping current: 6, 8 A
Trigger voltage: 230 V
... life due to a dropout delay. Specially recommended for liquid-filled measuring instruments. Technical data Supply voltage AC 230 V, 50 – 60 Hz Power input 6 VA Control voltage DC 35–40 V pulse Switching output ...
Tripping current: 30 mA - 5,000 mA
Trigger voltage: 230 V
... A and AC earth leakage relays, type B earth leakage relays are able to detect residual currents with both DC and AC components. This relay is used ...
Tripping current: 30 mA - 5,000 mA
Trigger voltage: 230 V
... A and AC earth leakage relays, type B earth leakage relays are able to detect residual currents with both DC and AC components. This relay is used ...
... and easily. The SubMonitor is the latest innovation in 3-phase pump protection from Franklin Electric. Using state-of-the-art technology, the SubMonitor provides the ultimate protection for a pump and ...
Tripping current: 8 A
Overexcitation controls from KUHSE are used to increase the starting force of actuating solenoids. Consequently the attraction time is minimized automatically. Individual solutions can be supplied according to the customers´ request. ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining