- AC transformer
AC transformers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary voltage: 600 V
... 1411 Current Transformers (CTs) are low voltage transformers for various power measurement devices and applications, including protective relays, analog devices, transducers, and PowerMonitor™ products. • ...
Output power kVA: 0.105, 210 kVA
Primary voltage: 115, 230 V
Secondary voltage: 24 V
... Safety isolating transformer of the PST100 series are powerful and robust transformers to power devices with low alternating input voltage. The PST10024 transforms AC line voltage into ...
Output power kVA: 0.105 kVA
Primary voltage: 115 V - 230 V
Secondary voltage: 12, 24 V
... Safety isolating transformer of the PST100 series are powerful and robust transformers to power devices with low alternating input voltage. The PST10012 transforms AC line voltage into ...
Primary current: 2.5 A - 1,500 A
Needs an output power supply of 10...28 V dc Primary current: from 2.5 to 1500 A ac, depending on the type Secondary current: 4..20 mA Internal diameter: from 35 to 105 mm, depending on the type Busbar dimensions: ...
Electric power: 0.025 kVA
Accuracy class 1 Power 25 V·A Used in AC electricity lines to obtain a lower voltage in the secondary than in the primary, so that it can be measured by electronic equipment
Primary current: 300 mA - 125,000 mA
Earth leakage protection device for the protection of people and property against fault currents, such as: - Sinusoidal alternating currents and pulsating residual direct currents.. - Sinusoidal alternating currents, up to 1 ...
Output power kVA: 0.01 kVA - 0.01 kVA
Secondary voltage: 100 V - 100 V
Frequency: 40 Hz - 60 Hz
Measurement voltage transformers for voltages from
Output power kVA: 0.005 kVA
Primary voltage: 1,140 V
Secondary voltage: 380 V
Product Overview: Three-phase Dry-type Transformer (for Frequency Conversion): Specially designed for frequency conversion systems, it efficiently converts electrical energy, precisely matches the requirements of frequency ...
LUSHAN CHINA
Output power kVA: 24 kVA
Primary voltage: 380 V
Secondary voltage: 220 V
... industry, it converts AC to DC for rectification. Suits new energy equip., optimizes power, offers stable DC for efficient prod. Specific Introduction: 1. Rectify & Convert Precisely Has a rectifying function. Converts ...
LUSHAN CHINA
Output power kVA: 5 kVA
Primary voltage: 1,140 V
Frequency: 50, 60 Hz
Product Overview: This single-phase transformer is for coal quality industrial analyzers. It changes power, fits voltages, and blocks interference, powering precise tests and keeping gear steady in tough setups. Specific ...
LUSHAN CHINA
Primary voltage: 11 V
Secondary voltage: 30 V
Primary current: 300 A
... QI-300-I is an AC/DC current transformer which is galvanically isolated from the measuring circuit. The function and appearance of this device are very similar to a standard active CT, however it is able ...
qeed
Primary current: 0 A - 50 A
Frequency: 20 Hz - 2,000 Hz
AC/DC current transformer (TRMS) to 4/20mA current loop, with isolation, high precision. 0…25 …50 A In alternating current it measures the true effective value (TRMS). In direct current ...
Output power kVA: 0.005 kVA
Primary voltage: 120 V
Secondary voltage: 12 V
Input Voltage: 120V AC Output Voltage: 12V AC Rated Power: 50VA Core Material: High Permeability Silicon Steel Dimensions: Inner Diameter (I.D.): 70 mm - Outer Diameter (O.D.): 90 mm, Height: 20 mm
Output power kVA: 0.3 kVA
Primary voltage: 220 V
Secondary voltage: 12 V
Our 300VA Toroidal Transformer is the ideal solution for your power supply needs. With an output of 12V AC and a power rating of 300VA, this transformer offers reliable and stable performance ...
Secondary voltage: 333, 100 mV
Primary current: 5 A - 600 A
Secondary current: 40, 100 mA
Split Core Type Easy Installation CE/ROHS Approved Electrical Specifications • Insulation Voltage : 600V AC • Measurement Range : 20%In~120%In • Accuracy : Class 0.5/Class 1 • Phase Angle : <2° at 50% Rated Current • ...
Rayfull Electric Technology(Zhejiang)Co., Ltd.
Secondary voltage: 333, 100 mV
Primary current: 5 A - 5,000 A
Secondary current: 100 mA
Split Core Type Easy Installation CE/ROHS Approved Electrical Specifications • Insulation Voltage : 600V AC • Measurement Range : 20%In~120%In • Accuracy : Class 0.5/Class 1 • Phase Angle : <2° at 50% Rated Current • ...
Rayfull Electric Technology(Zhejiang)Co., Ltd.
Secondary voltage: 333, 100 mV
Primary current: 5 A - 1,200 A
Secondary current: 100, 40 mA
Split Core Type RJ12 Terminal Easy Installation CE/ROHS Approved Electrical Specifications • Insulation Voltage : 600V AC • Measurement Range : 20%In~120%In • Accuracy : Class 0.5/Class 1 • Phase Angle : <2° ...
Rayfull Electric Technology(Zhejiang)Co., Ltd.
Primary current: 100 A - 600 A
... series offers a range of split core current transformers designed for installation into existing plants where removal of busbars/cable lugs prevent installation of standard current transformers. To ...
... series offers a range of solid core current transformers. The inepro solid core current transformers are perfectly suitable for installation in combination with a PRO380 CT smart energy meter. To measure ...
Output power kVA: 100 kVA - 20,000 kVA
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
... Compared to the existing EcoDesign Tier2 Transformers set by the European Community, EcoPlus2030 Transformers boast significantly reduced CO2 emissions and losses. Just like the olive tree, our EcoPlus2030 ...
Tesar Srl
Frequency: 60, 50 Hz
... of cast resin transformers mainly used for energization of rails, metros, highspeed trains, tram- ways, braking energy recovery systems and auxiliary services for sta- tions and signalling. The range of production includes ...
Tesar Srl
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
Frequency: 50 Hz - 60 Hz
Tesar offer a wide range of customized solutions for feeding Data Centres: • Transformers with K factor up to 20 (high harmonic content) • Electrostatic screen between primary and secondary • Simplified Busbars connection ...
Tesar Srl
Electric power: 50 W - 2,000,000 W
Primary voltage: 1 V - 1,000 V
Secondary voltage: 1 V - 1,000 V
The single-phase and three-phase transformers and auto-transformers are equipped with either copper or aluminum windings. These units feature air-type cooling and can perform up to 2000 kVA, with a frequency ...
Electric power: 50 W - 2,000,000 W
Primary voltage: 1 V - 1,000 V
Secondary voltage: 1 V - 1,000 V
Our 1-Ph and 3-Ph insulation transformers are designed to meet the following priority requirements: Anti-jamming screening between the primary and secondary windings Cooling: air type Power: up to 2000 kVA Frequency: ...
Electric power: 1 W
Primary voltage: 3.3 V - 5 V
Secondary voltage: 3.3 V - 15 V
... 125 °C RoHS compliant Applications Isolated RS-485/RS-232 power supplies Industrial automation AC motor drives Smart metering Solar inverters
Electric power: 15,000,000 W
Primary voltage: 12, 3, 25, 15, 1.5 kV
The perfect transformer for every vehicle Siemens Energy designs and manufactures Tractronic® traction transformers for rail operators and train manufacturers worldwide, that increase train efficiency ...
Output power kVA: 405,200, 700,000, 1,000,000, 3,000, 1,500,000 kVA
Primary voltage: 1,000 kV
Secondary voltage: 800, 66, 500, 750, 1,000 kV
... featured in the performance of high reliability, low loss, low noise, low temperature rise, low partial discharge etc. The transformer is built into the wind generator nacelle, which can realize the local voltage boost ...
Primary voltage: 0 V - 245 V
Secondary voltage: 0 kV - 1,050 kV
... high voltage transformers suitable for electrical generation, transmission and distribution applications: Transformers GSU (Generator Step-Up): used to connect the generator voltage level up to the ...
SEA
Primary voltage: 230 V
Secondary voltage: 0 V - 250 V
Primary current: 0.8 A - 20 A
... 20 A Insulation class B Maximum ambient temperature 45 °C Degree of protection IP 00 Advantages Stepless adjustment of the AC voltage from zero to the maximum value Self‑cleaning of the exposed contact tracks 4‑point ...
Primary current: 0 A - 20 A
... EDS441LAB series. The measuring current transformers are connected to the respective devices via a 2- or 6-core cable. They can be used in DC, AC, and 3(N)AC systems. The CTUB101-CTBCxx ...
BENDER
Electric power: 0.024 kVA
Primary voltage: 230 V
Secondary voltage: 24 V
The CA1A is an economical transformer which reliably delivers either 12Vac or 24Vac and benefits from short circuit protection. Ideal for running a simple keypad and electric strike, this transformer ...
Electric power: 3,500 W
Primary voltage: 220 V - 420 V
Secondary voltage: 200 V - 430 V
Features •LLC resonant 3.5 kW full-bridge transformer •Works with Lr = 22µH and Cr = 33nF •Frequency range 70-200kHz •Reinforced insulation between prim/sec and with core •UL94 and RoHS materials (F/155°C) •Design ...
PREMO
Electric power: 30 W - 1,600 W
Secondary voltage: 30 V - 900 V
PSK & PZT AC test transformers are especially designed for testing objects of medium capacitance in the factory, indoor or outdoor. PSK & PZT test systems are particularly suited for tests requiring ...
Primary current: 5 A - 450 A
Current transformer with built-in transducers ø 35mm Primary current field-selectable 9 programmable ranges Output 0..,20mA - 4..,20mA - 0...10V d.c. 4-wire technology, a.c. auxiliary supply
Primary voltage: 10, 20 kV
... immersed power transformer is composed of core, coil, voltage regulating switch, oil tank and other components, and the dielectric material is dielectric oil. Description The oil immersed power transformer ...
Beijing SOJO Electric Co., Ltd
Secondary voltage: 1, 5 V
Primary current: 1, 5 A
... outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type ...
BEIJING GFUVE ELECTRONICS CO.,LTD.
Primary voltage: 230 V
Secondary voltage: 4 V - 12 V
Bell transformer ZTR-15-12Designated for general use – e.g. as home bells supply, door locks supplyDESCRIPTION Short-circuit-proof, doubled output terminalsTECHNICAL PARAMETERS Input voltage: AC ...
ELKO
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining