- Detection - Measurement >
- Electrical Measurements >
- Calibrator
Calibrators
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Voltage: 1 mV - 200,000 mV
... up to 4 GHz and precisely controlled pulse edges, setting a new standard in calibration performance. Unlike conventional calibrators, the 9500C's Active Head Technology™ allows for adjustable output amplitudes between ...
Fluke Calibration
The Rosemount 8714D Transmitter Calibration Standard ensures traceability to NIST standards and long-term accuracy of the flow meter system. This high-precision instrument can be used to recalibrate Rosemount 8712 C/D/E, 8732 C/E, and ...
Noise level: 114, 94 dB
... CAL73 sound level calibrator is used to calibrate sound level meters and other sound measurement equipment. You can calibrate 1 inch diameter microphones directly and 1/2 inch microphones using a 1/2 inch adapter supplied ...
Pressure: 80,000 Pa - 3,500,000 Pa
Voltage: 0 V - 50,000 V
... measurement, which makes it the most accurate calibrator in the portable calibrator class. Field Calibration of Differential Pressure and Pressure Transmitters Calibration of pressure transmitters ...
Descriptions Calibration Syringe of pulmonary function instrument Gasboard-7050 is mainly used for daily calibration and inspection of pulmonary function instrument or Spirometer. It adopts low traction piston, which is easy to operate, ...
... overall machine accuracy Rapid calibration using XR20 provides up to ±1 arc second accuracy: The XR20 rotary axis calibrator works in conjunction with XL-80 and XM-60 laser systems. It consists of an integrated ...
PDC-100 is a highly integrated portable calibrator with an internal air compressor. One device can complete clean zero gas generating and calibrate gases output. The high precision mass flowmeters with external cylinders ...
Temperature: 0 °C - 40 °C
FPI AQMS-200 multi-gas calibrator utilizes mass flow controller to perform standard zero and span calibration with up to 4 gas sources. Key Features • Stable trace level ozone output down to 0.1ppm; • Optional ozone ...
The K3607 calibration unit can be used to calibrate measuring amplifiers or measurement chains without imposing a mechanical quantity on the strain gage transducers belonging to the measurement chain. The K3607 calibration unit can ...
HBM Test and Measurement
• Allows a quick check of high voltage output to be performed • Tests up to 100kV at an accuracy of 3% of full scale deflection • Easy to read mirror arc display with tolerance bands Accessory Voltage Calibration Meter for use with ...
Noise level: 94 dB - 114 dB
The C.A 833 Calibrator is a standard source (1kHz) used for calibrating sound level meters. * Compliant with the IEC 942 type 2 standard * Calibration level: 94 and 114 dB * Usable microphone diameter: 2.5 cm / 1.3 cm / 0.64 cm
CHAUVIN ARNOUX
Temperature: -250 °C - 1,800 °C
The compact, simple-to-use C.A 1621 thermocouple temperature calibrator is capable of measuring and simulating up to 8 types of thermocouples (J, K, T, E, R, S, B, N), as well as a voltage in mV. When used as a battery-powered ...
CHAUVIN ARNOUX
Temperature: -200 °C - 800 °C
Compact and simple to use, the C.A 1623 calibrator is capable of measuring and simulating up to 7 different probes as well as a resistance. When used as a battery-powered stand-alone instrument, it offers a long battery ...
CHAUVIN ARNOUX
automatically calibrates electronic torque and angle-controlled wrenches made by STAHLWILLE design patent protected by national and international patents model is the same as perfectControl® No 7794-2, except it is ...
STAHLWILLE EDUARD WILLE GmbH & Co. KG
The EXTT Series Torque Testers provide a rapid and user friendly way to calibrate and setup lower torque handheld precision for the fastening of tools. This includes electric and air screwdrivers, pulse tools, and nut runners. As a ...
Expert Joint Simulator kits are used to simulate various joint conditions in the tool crib or laboratory away from the actual joint. The Simulator joint rate can be easily changed to emulate different joint conditions from hard to soft. 1.0 ...
Temperature: -50 °C - 250 °C
Pressure: -0.85 bar - 25 bar
Voltage: 24 V
... memory Intrinsically safe version Description General information The model CPH7000 process calibrator is a precise, portable calibrator for the calibration and checking of analogue pressure ...
WIKA Alexander Wiegand SE & Co. KG
Temperature: 20 °C - 375 °C
Voltage: 230, 110 V
... simple testing of thermometers is a “must” when it comes to the operational safety of machines and plants. The portable calibrators of the CTx9100 family are particularly suited to local calibration tasks and extremely ...
WIKA Alexander Wiegand SE & Co. KG
Temperature: -55 °C - 200 °C
Voltage: 240 V
... plants. The portable dry well calibrators of the CTD9100 family are particularly suited for on-site calibrations and are extremely user-friendly. Due to their compact design and their low weight, the dry well calibrators ...
WIKA Alexander Wiegand SE & Co. KG
Temperature: -200 °C - 2,315 °C
Industrial Thermocouple Handheld Calibrator • Handheld Thermocouple Calibrator with ±(0.003% Rdg +5 µV) accuracy • Resolution: 0.01° • 500 Hour Battery Life • Simultaneous Source / Measure • MIL-STD ...
Voltage: 0 V - 10 V
Multifunction 4-20mA/0-10V Process Calibrator HT8051 is a professional digital process calibrator capable of generating and measuring signals of DC voltage and current up to 10V and 24mA respectively ...
Temperature: -20 °C - 49 °C
Pressure: 10,000 psi
Voltage: 0 V - 30 V
The Ashcroft® ATE-2 handheld digital calibrator is a portable, multifunction instrument performing precision measurement of pressure, temperature, current or voltage. The base unit includes application-specific firmware ...
ASHCROFT
Temperature: -10 °C - 55 °C
Pressure: -830 mbar - 2,000 mbar
Voltage: 9 V
... for field use. Pump Up the Pressure The Fluke 718Ex Intrinsically Safe Pressure Calibrator is a powerful intrinsically safe, self contained pressure calibrator for usage in explosion endangered areas.
FLUKE
Temperature: -10 °C - 50 °C
Voltage: 12 V - 30 V
•Especially compact construction •Open design •Fitting holes for exat positioning •Adjustment in X-, Y- and Z-axis •Slave connector for further sensors APPLICATION: PLANTS AND MACHINES | INDUSTRIAL AUTOMATION •Fitting holes ...
CAPTRON
Temperature: -10 °C - 50 °C
Voltage: 12 V - 30 V
•Especially compact construction •Reduced mounting and calibration effort •Fitting holes for exact positioning •Adjustment in X-, Y- and Z-axis APPLICATION: PLANTS AND MACHINES | INDUSTRIAL AUTOMATION •Fitting holes for exakt ...
CAPTRON
Temperature: -10 °C - 50 °C
Voltage: 12 V - 30 V
•Especially compact construction •Open design •Adjustment in X-, Y- and Z-axis APPLICATION: PLANTS AND MACHINES | INDUSTRIAL AUTOMATION •Adjustment in X-, Y- and Y-axis Both axes are measured at the intersection •Open design ...
CAPTRON
The CS 2890 Power Calibrator/Simulator is a handheld multifunctional four-phase instrument designed for calibrating and adjusting Metrel power quality Class A and Class S analysers as well as simulation of typical voltage ...
Voltage: 50 V - 300 V
The MI 2891 Power Simulator is a multi-purpose three phase power simulator for simulating typical situations in low voltage power supply systems. It is an excellent tool for training, demonstration purposes, or as an electrical didactic ...
Temperature: -10 °C - 50 °C
Noise level: 94, 114 dB
Class I Acoustic Calibrator PCE-SC 09-ICA incl. ISO Calibration Certificate Sound calibrator for mobile use / For various evaluation filters / Accuracy IEC 942, class 1 / For microphones with different ...
Voltage: 0 V - 40,000 V
The Buckleys Calibration Meter Pro’ offers a quick, accurate and cost-effective method of checking the calibration state of high-voltage DC equipment. It has been primarily designed for use with the Buckleys’ PHD Pro’, PD and PHD range ...
The Calibration Kit has been created to provide all the necessary components to enable customers to verify the accuracy of the readings on the Buckleys or Roxby BathyCorrometers so that ‘in-house’ calibration certificates can be issued. The ...
The Calibration Kit has been created to provide all the necessary components to enable customers to verify the accuracy of the readings on the Buckleys Contact and Proximity Probes so that ‘in-house’ verification certificates can be issued. Providing ...
Voltage: 0 V - 1,000 V
Multifunction calibrator 9010 is designed as universal calibration tool for electrical calibration laboratories, covering most of their workload like multimeters, clamp meters, ohm meters, power meters and power analysers, ...
Meatest spol. s r.o.
Voltage: 0 V - 1,050 V
Multifunction calibrator 9010+ is designed as universal calibration tool for electrical calibration laboratories, covering most of their workload like 6½ digit multimeters, clamp meters, ohm meters, power meters and power ...
Meatest spol. s r.o.
Voltage: 0 V - 1,050 V
9000 Portable Multifunction Calibrator is designed specifically for calibration of 3½ and 4½ digit multimeters. Advancing from M143 predecessor, the 9000 comes with much wider frequency ranges, capacitance function and ...
Meatest spol. s r.o.
Radio Influence Voltage (RIV) measurement calibrator Reliable partial discharge testing on transformers Our RIV1 calibrator is used for the calibration of high-voltage partial discharge (PD) test ...
The new, compact multifunction process calibrator convinces by ruggedness, simple handling, highest functionality, precision and PC system ability. The METRAHIT MULTICAL rationalizes measuring, calibrating and revision ...
The METRAHIT CAL calibrator functions as a highly accurate calibration and simulation instrument for electrical quantities. CE Conformity Measuring Category CAT I Protection IP 54 DAkkS National Accreditation Body ...
Voltage: 0 V - 2 V
Features: * Oyster case with flip-up display is ideal for handheld or benchtop applications * Large 3-1/2 digit LCD display and touch keypad * Display readings in mA or as a % of the 0 to 24mA range or as mV in voltage ranges ...
Extech
Your suggestions for improvement:
Since sensors and measuring instruments must be precise and reliable, they must be checked regularly. This periodic verification and adjustment is known as calibration. The device used to perform these tasks is a calibrator.
ApplicationsThese instruments are found in all industrial sectors where the measurement of temperature, pressure and other values must be as exact as possible. They are used in laboratories and in a variety of manufacturing processes.
TechnologiesCalibrators include a variety of tools and devices for calibrating sensors and other measuring instruments. They provide a standard value to which the readings of the instrument being checked can be compared. For example, a liquid of known temperature can be used to calibrate a thermometer.
How to chooseChoice will depend on the parameters to be tested. There are temperature, pressure, acoustic, current loop, process and multifunction calibrators.
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining