Primary current: 32 A - 65 A
VAC: 400 V
PKE motor-protective circuit-breakers with electronic wide-range overload protection offer an interesting alternative to the bimetal solution for motor currents up to 65 A. PKE motor-protective circuit-breakers ...
Primary current: 15,000 A
VAC: 24 kV
The compact design of the HB3-C generator circuit-breaker is customizable and offers an ideal solution for retrofit projects and new applications. It’s maintenance-free and SF6-free for more efficiency ...
Primary current: 1.6 A - 2.5 A
VAC: 400, 230, 500 V
... Description - R. STAHL's 8146/5-V27 series moulded case circuit breakers for motor protection protect Ex e and Ex d motors and their associated electric lines and systems. The standard variants feature ...
Primary current: 4 A
VDC: 24 V
... electronic circuit breakers support, via a digital input and output, active switching on or off of any output channel, resetting of tripped circuits and simultaneous reporting of current ...
Block Transformatoren-Elektronik
Primary current: 1 A - 20 A
VDC: 24 V
... electronic circuit protector selectively protects all DC 24 V load circuits up to 20 A and limits the output current linearly during switch on or before tripping. The limitation cuts down the current ...
Primary current: 63 A
... undervoltage trip unit are the internal accessories installed on the series. The user can freely choose on either fixed and adjustable protection. It complies to the safety guidance standard of IEC 60204-1. It also ...
ETI
Primary current: 16 A - 630 A
VAC: 400, 230 V
... series leakage MCCB is mainly used in the circuit of AC 50/60Hz, rated working voltage up to 400V, and rated current from 16A-630A in distribution line for distributing power, protecting line, overload, short-circuit ...
VAC: 400 V
Rating: 16 A - 800 A
... the circuit and power equipment from overload, short circuit, under-voltage, and other faults. At the same time, it can also be used as the infrequent start and overload, short circuit, ...
Primary current: 500 A - 630 A
VAC: 690 V
... Specification : BM630-CN Thermal adjustable magnetic Standards:CNS14816-2 (IEC60947-2) Voltage Ui:690V Current:500.600.630A Pole: 3P 4P Breaking Capacity: Icu: 220V/ 35kA (sym) 380V/ 25kA (sym) 440V/ 22kA (sym) Ics ...
Shihlin Electric & Engineering Corporation
Primary current: 12.5 A - 800 A
VAC: 230 V - 500 V
VDC: 125 V - 250 V
Adjustable Thermal and Fixed Magnetic Trips : Frame Size: 125~800AF(3Pole & 4Pole) Rated Current: 12.5A~400A adjustable Rated Current: 630A~800A Fixed Breaking Capacity (IEC 60947-2 AC380V Icu) : 65kA
... 7035 polyester coating. EFD3 series three pole, magnetothermic breakers are used for command (start - stop) and protection of three-phase motors. Circuit breaker with adjustable ...
The 8146/5-V27 series motor circuit breakers from R. STAHL protect Ex e and Ex d motors as well as their associated conductors and systems. The standard versions are fitted with an adjustable ...
Primary current: 0.25 A - 25 A
EFD3 series three pole, magnetothermic breakers are used for command (start - stop) and protection of three-phase motors. Circuit breaker with adjustable magnetothermic ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining