- Building - Construction >
- Industrial Building Equipment >
- Air heater unit
Air heater units
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Heating power: 5 kW - 133 kW
Air flow: 1,200 m³/h - 11,500 m³/h
Heating power: 6 kW - 60 kW
Air flow: 1,500 m³/h - 4,825 m³/h
The heating units are a key element of modern heating to achieve optimum heating efficiency and comfort in various types of buildings. The Warmex heating unit is designed ...
Stavoklima
Heating power: 14.1 kW - 42.1 kW
Air flow: 2,600 m³/h - 4,525 m³/h
... part of the unit input air from the interior, air is heated through passing through circular heat exchanger, and output slats arranged on circumference of the unit distribute ...
Stavoklima
Heating power: 7.7 kW - 61.9 kW
Air flow: 2,225 m³/h - 5,825 m³/h
The heating units are a key element of modern heating to achieve optimum heating efficiency and comfort in various types of buildings. Nevada heating units are designed ...
Stavoklima
Heating power: 20,880 W - 106,410 W
Air flow: 1,758 m³/h - 8,875 m³/h
... water, by means of a circulation pump, passes through the interior of the heating coil of the air heater and the heat transfer is carried out by the air fan of the air ...
MET MANN
Heating power: 19 kW - 106 kW
Air flow: 1.7 m³/h - 8.9 m³/h
... distributed inside the coil. Air, driven by an axial fan, passes through this coil, allowing the temperature to be transferred to the air. In this way, the resulting air is diffused in ...
MET MANN
Heating power: 5 kW - 120 kW
Air flow: 1.6 m³/h - 5.7 m³/h
... to the room to be heated by means of a powerful 3-speed axial fan. The range consists of 7 models capable of developing heating capacities from 5 to 120 kW and flow rates from 1,600 to 5,700 m3/h. They can work ...
MET MANN
Heating power: 15 kW - 100 kW
Air flow: 2,500, 3,500, 5,000, 6,500 m³/h
AP unit heaters are water heating units. They also perform a cooling function when used with cold water. They are an environmentally friendly solution, especially ...
Heating power: 87 kW - 113 kW
Air flow: 6,500 m³/h
The AP Max unit heater is innovative because it uses polypropylene for the construction of its supporting structure. The technical choice of this material and the cataphoresis painting treatment of the ...
Heating power: 80, 110 kW
... Indirect oil fired air heater with 2 stage Master burner Heating power: 80/110 kW Main features: - Clean hot air - Possibility to connect flexible tubes to distribute ...
Heating power: 7.5, 15 kW
Air flow: 1,700 m³/h
Master electric fan heaters are highly efficient devices widely used in variety of applications. They provide clean, fast and safe heating. Electric heaters are ideal for temporary or emergency heating ...
Heating power: 11.4 kW - 72.1 kW
Air flow: 1,200 m³/h - 6,300 m³/h
... engineered for use in ATEX-zones 2 (gas) and 22 (dust) and direct connection to your existing central heating system. This ATEX heater can be applied for heating your production or storage ...
Heating power: 5,000 W - 80,000 W
Air flow: 2,700 m³/h - 9,000 m³/h
... with a heating capacity from 5.4 to 82.0 kW is available. The units are suitable for both wall and ceiling mounting. A variety of exhaust gas and fresh air versions rounds out the flexible ...
Gas multi-directional air heaters The range of gas multi-directional heaters from Biddle Air Systems have proven an instant hit with customers needing to heat large ...
Biddle
... multi-directional design induces movement in the air around the unit ensuring warm or cool air is distributed evenly throughout the room. NOZ2 Cooling NOZ2 Cooling provides both ...
Biddle
... re-modeling of the traditional unit heater, developed to address the heating and air distribution needs of warehouses and industrial buildings. NOZ 2 features six adjustable ...
Biddle
Heating power: 3 kW
Air flow: 85 m³/h - 230 m³/h
... V-Shaped Fins | PTC Air Heater PTC Air Heater HRKK with v-shaped fins for homogeneous heating of air flows Power up to 3kW High ...
DBK Industrial Thermal management
Heating power: 19,000 W - 110,000 W
S.PLUS
... fuels utilising an independent combustion air fan which allows air discharge temperatures of up to 1200°C. GASAIRBLOC Direct Process Air Heater Characteristics Robust ...
Air heating cassettes With Kanthal® air heating cassettes it is possible to heat air or gases up to 800°C (1470°F) and maintain a uniform temperature ...
Heating power: 100 W
HVR Pentagon Anti-Condensation Heaters HVR Pentagon anti-condensation heaters have been designed for use where a low wattage heater is required to prevent condensation. They comprise ...
Heating power: 80,000 W
Air flow: 6,000 m³/h
Because the units carry the label made in Germany you can be sure that you are buying a top-quality, highly efficient and extremely reliable heating unit which will carry on heating in ...
Trotec GmbH
Heating power: 5,400 W - 21,900 W
Air flow: 1,000 m³/h - 12,000 m³/h
... large areas (industrial premises or workshops, warehouses, large stores, garages, gymnasiums, multi-purpose halls …). This air heater can be used for overall or back-up heating, either permanently or ...
Heating power: 40 kW - 140 kW
Air flow: 0 m³/h - 12,500 m³/h
Flexible air heater with customized components for wall and ceiling Robust construction Multifunctional applications in industry Easy selection Design or industrial version of casing The ...
FläktGroup
Heating power: 613,100 BTU/h
NYB Unit Heaters are designed for continuous operation in the industrial environment. With their rugged, low-maintenance design, Unit Heaters are well-suited for space-heating ...
Heating power: 22,000, 15,000, 9,000, 5,000, 3,300 W
Air flow: 400 m³/h - 2,400 m³/h
The Helios heater range includes product solutions for portable and fixed installation to match many heating and ventilation applications. The use of STH/TH and SH heaters ...
Heating power: 6.9 kW - 52.2 kW
Air flow: 1,600 m³/h - 4,000 m³/h
Maximus - Air heating and handling units Air handling and heating units Maximus are intended for use in heating and ventilation ...
Dospel
Heating power: 13.9 kW - 133.3 kW
Air flow: 1.3 m³/h - 12.6 m³/h
Heating power: 22 kW - 81.2 kW
Air flow: 1,900, 3,000, 4,600, 7,500 m³/h
AIRLAT
Heating power: 24,000 W
The air heat dryer applies the reverse Carnot cycle principle to draw heat from the air and transfer it to the room, raising the temperature to assist in drying items. It includes a finned evaporator ...
Sichuan Western Flag Drying Equipment Co., Ltd
Condensing industrial warm air heaters IH/AR K Warm air heaters for industry floor standin
Blowtherm S.p.A.
... diagnostics to be performed on the PTC air heater and its heating circuits. Every circuit can be monitored individually and switched off, if required. Furthermore, the system monitors ...
Heating power: 2,500 W - 35,000 W
... facilities, wastewater treatment plants, etc., where specific explosive gases or dusts maybe present. All FE2 heaters feature the VacuCore® liquid-to-air heat exchanger, which provides greater efficiency, ...
CCI Thermal Technologies Inc.
Your suggestions for improvement:
An air heater is a heating apparatus used in large industrial and commercial spaces. It takes in ambient air, passes it through a heat exchanger and redistributes it as a function of the configuration of the space and the desired level of comfort.
ApplicationsAir heaters are high-power heaters used to heat large-volume spaces such as industrial buildings, warehouses, workshops, sports arenas, etc.
TechnologiesThe three principal types of air heater differ according to their energy source.
- Hot water and steam heaters circulate hot water or steam through a heat exchanger coil.
- In electric models, the exchanger contains a resistance element.
- Gas heaters use a burner to heat the air passing through the exchanger.
Their blowers can be helical or centrifugal.
The range of on-site energy sources (electricity, gas, hot water/steam network) and regulations governing the activity in question will determine the choice of heater.
A thermal study of the area to be heated, its size and layout will dictate the number, power and flow rate of the heaters.
- Powerful
- Can heat large air volume
- Significant circulation
- Avoids thermal stratification
- Slow to start
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining