Nominal voltage: 600 V
Temperature: -65 °C - 150 °C
Aluminum Wire & Cable, 0 AWG Wire Size, 53.5 mm² Wire Size, White Cable Color • Alias #: 3-1199377-7 • Wire Size (AWG): ...
Nominal voltage: 600 V
Temperature: -20 °C - 80 °C
Lapp Muller
Nominal voltage: 300, 1,200 V
Temperature: -40 °C - 90 °C
Cross-section: 0.25, 0.34, 0.75, 1.5 mm²
... current meter marking Halogen-free flexible paired data cable with aluminum pair screen and overall copper screen especially for use in shipbuilding industry. The flexible & flame retardant cable ...
Cross-section: 0.32 mm²
Length: 5, 10, 2 m
SENTINEL- communication connector, which is specially used for Ethernet communication. The cable conforms to ISO/IEC 1180 (Cat.5) and TIA/EIA-568-C.2 (Cat.5e) standards. RJ45 and M12 D codes are available for connectors.
... E-MOBILITY electric cables. High temperature silicone cables T150, T180 Cross-linked cable. Type FHLR2GCB2C, FHL2G Automotive charging cable H05BZ5F, H05BZ7F, SO5BQF ...
Canare 75 ohm Super Low Loss Coaxial Cable ・Best suited to 3G-SDI/HD-SDI transmission. ・Highly-foamed PE insulation allows further improvement in the attenuation characteristics. ・Multi-layer insulation in which to ...
Nominal voltage: 300 V - 1,500 V
Temperature: -30 °C - 70 °C
... core identification data pair: blue, white power pair: red, black stranding twisted pairs individual shield aluminum / PES tape with drain wire overall shield tinned copper braid outer sheath PVC sheath ...
CAE GROUPE
Nominal voltage: 250, 1,500 V
Temperature: -30 °C - 70 °C
The MP-22E cables enable the transport of electronic, signaling and communication signals in pertubated area thanks their dual shielding (braid + alu tape) conform to RoHS conductor material stranded tinned copper conductor ...
CAE GROUPE
Nominal voltage: 300 V
Temperature: -20 °C - 80 °C
... mm core identification black and transparent stranding 2 conductors twisted together overall shield aluminium / polyester, coverage 100% drain wire 7 x 0.20mm general tape PES tape outer sheath ...
CAE GROUPE
Nominal voltage: 1,000 V
Temperature: -60 °C - 80 °C
... When using the applicable cable gland, it is possible to insert the cable directly into flameproof enclosures. The ASKDP03-T is a high speed cable for Industrial Ethernet for fixed installations ...
Nominal voltage: 2,000 V
Temperature: -40 °C - 80 °C
... transmission performance The cable has excellent tensile and compressive properties Conductor: stranded tinned copper conductor Insulation: PE Color: white, yellow, blue, orange Inner sheath: PVC / LSZH Shielding: ...
Zhaolong Interconnect
Nominal voltage: 1,000, 600 V
Temperature: -40 °C - 70 °C
Cross-section: 10 mm² - 630 mm²
... kV Three phase systems 1.2 kV Minimum bending radius - single core 15x Outer-Ø multi core 12x Outer-Ø Aluminium conductor, single wire acc. to DIN VDE 0295 cl.1 / IEC 60228 cl.1 multi wire acc. ...
HELUKABEL
Length: 5, 3, 2, 1 m
... signal loss and screen ghosting. All cables have moulded hoods whereby the inner hoods are soldered 360° to the connector for end-to-end shielding. Conductors — 28 AWG stranded wire Contacts — Copper ...
Category 7A twisted pair ethernet cable is used to connect network devices such as Ethernet hub, router, and network switch. The bandwidth of Cat 7A network cable is up to 1000 MHz and also provide positive ...
Nominal voltage: 1 kV
Temperature: -20 °C - 90 °C
... .The installation temperature of the cable shall be no less than -20 °C. Construction 1.Phase conductor: Aluminum conductor 2.Neutral conductor: Aluminum alloy conductor 3.Public ...
Henan Tong-Da Cable Company
Nominal voltage: 200, 250, 320 kV
Temperature: -30 °C - 60 °C
... experienced and reliable manufacturer and solution provider of submarine power cables. It forms about 4,000 kilometers of medium voltage (hereafter called MV) power cables annual output and becomes a ...
ZTT
Nominal voltage: 0 kV - 500 kV
... electric wire&cable is used for transmit power(magnetic energy),information and to transform the electromagnetic energy, which is mainly divided into 5 major categories: bare conductor, magnetic wire, power cable, ...
Temperature: -40 °C - 70 °C
... fibre cables- Part 3-11 • Water resistance of optical cable is ensured by the following measures: • Special water-blocking compound filled in loose tubes 1. For color arrangement of fibres and loose ...
Yangtze Optical Fibre and Cable Joint Stock Limited Company
Temperature: 90 °C - 260 °C
Length: 15 mm - 55 mm
Our automotive cables are the reliable and efficient connection for each wiring system. We offer an extensive range of products with various OEM and Tier 1 approvals. We supply both by international standards and the ...
LEONI
Nominal voltage: 220 kV
Temperature: 90 °C
Cross-section: 240 mm² - 2,500 mm²
... 5S ), the conductor temperature: not exceed 250 ℃ 4、0℃,≥18D (D) The minimum temperature of cable laying: 0℃ The minimum bending radius≥ 18D (D is the cable outer diameter )
Shanghai Morn Electric Equipment Company
Temperature: 150, 210, 90, 120 °C
Aluminum tube supports heat resisting aluminum alloy expanding wire
Nominal voltage: 76 kV - 500 kV
Temperature: 90 °C
Cross-section: 240 mm² - 2,500 mm²
... you: from consulting on design through to implementation of your sophisticated high-voltage cable systems. Brugg Cables advises customers world-wide on new cable systems, as well as ...
Brugg Kabel AG
Stress transferring type strong steel core soft aluminum wire strand Main Features A、Energy saving of power transmission: high conductivity, energy saving when the line running, small loss. B、Material ...
Tongguang Group Company
Temperature: -40 °C - 150 °C
Cross-section: 3 mm² - 120 mm²
Nominal voltage: 15, 33 kV
... “Weather-Resistant Line Wire” and may consist of AAAC over which a covering has been applied • Conductor: Compacted Aluminum Alloy • Water Blocking: Water Blocking Material • Covering: XLPE
Sunway Company
Nominal voltage: 600 V - 30,000 V
Temperature: -5 °C - 90 °C
... stations, industry and distribution boards or subscriber networks, where mechanical damage to the cable is not expected (see DIN VDE 0298-1). The cables are insensitive to occasional impacts of oils and fuels.
Bayerische Kabelwerke
Nominal voltage: 450, 750 V
Temperature: 60 °C
Cross-section: 1 mm² - 630 mm²
Product Series: Special Cables Basic Parameters: Rated Voltag: 450/750V The Working Temperature: <60℃ Executive Standard: EN50525-2-21 Conductor Structure: Conductor Material: aluminum ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining