- Robotics - Automation - Industrial IT >
- Automation >
- Analog I/O
Analog I/O
Increased flexibility without PLC Used together with a Controller, the JVL Input-Output Module extends the number of inputs from 10 to 26 and the number of outputs from 3 to 11. Each I/O Module has 16 inputs and 8 outputs. Up to 31 ...
binary outputs module open collector type outputs LEDs for module operation and Modbus transmission signalling The SOC-8 binary outputs module is used to control the low-power output devices via the RS-485 connection. ...
analogue inputs module 8 independent analogue inputs (voltage or current) RS-485 / Modbus RTU LEDs for module operation and Modbus transmission signalling Module SIAi-8 allows to measure analog values from 8 current ...
binary inputs module 8 independent voltage inputs RS-485 / Modbus RTU LEDs for module operation and Modbus transmission signalling Module type SIN-8 allows to monitor 8 binary voltage inputs via the RS-485 connection. ...
KEB’s C6 Remote I/O system offers various options for connecting process signals to an EtherCAT network. It is made up of a C6 Remote I/O bus coupler and additional I/O modules. The C6 Remote I/O bus coupler converts the physical transfer ...
Product Feature: Flexible protocol module and I/O module plug and play, features as below: 1. designed with a max of 64 modules, each I/O module is built with 16 channels and each have LED indicator. 2.supports an overall of 1024 I/O ...
ODOT Automation
ODOT CN-8032 Profinet Network Adapter The CN-8032 Profinet network adapter supports standard Profinet IO Device Communication. The adapter supports MRP media redundancy, and it could realize ring network redundancy. And it supports ...
ODOT Automation
The CN-8033 EtherCAT I/O module supports standard EtherCAT protocol access. The adapter supports a Max. input of 1024 bytes and a Max. output of 1024 bytes. It supports 32 pcs of extended IO modules. Hardware Specification System ...
ODOT Automation
Analogue inputs plug-in card for the OMR 700 is fully isolated from the internal bus with a galvanic isolation also between individual inputs. The design of the cards allows their use at any position in the device. If during the use ...
Orbit Merret s.r.o.
Plug-in card for measuring resistance sensors is fully isolated from the internal bus with a galvanic isolation also between individual outputs. The design of the cards allows their use at any position in the device. If during the use ...
Orbit Merret s.r.o.
Plug-in card for measuring termocouple sensors is fully isolated from the internal bus with a galvanic isolation also between individual outputs. The design of the cards allows their use at any position in the device. If during the use ...
Orbit Merret s.r.o.
CANopen module with 4 analog Inputs • Resolution: Up to 20 bits • Programmable input voltage range: ±10V • Easy control cabinet wiring due to 3-lead connection • CANopen profiles according to CiA® specification CiA ...
esd electronics gmbh
CANopen module with 8 analog Inputs • 8 A/D-Converter Inputs • Resolution: 14 bit • Input voltage range: ±10.24 V • Sample rate: up to 100 μs / 8 channels simultaneously • CANopen profiles according to CiA® specification ...
esd electronics gmbh
CANopen module with 4 analog outputs • Resolution: 12 bits plus sign • Output voltage range: ±10V • CANopen profiles according to CiA® specification CiA 301 and CiA 401 Approved Reliability and Ease of Use • Electrical ...
esd electronics gmbh
R-D/A4, R-D/A8, R-D/A16 are modules with 4, 8, 16 optically isolated analog outputs (16bit ±10V) that send reference signals to drives, servocontrols, power solid state relays with linear input, or retransmit variables to recording devices ...
@ctiveIO I/O modules: smart intelligence for your system Our @ctiveIO I/O modules are as different as your individual automation solutions. Two sub-modules are combined in one module respectively in this smart system. You can thus ...
@ctiveIO I/O modules: smart intelligence for your system Our @ctiveIO I/O modules are as different as your individual automation solutions. Two sub-modules are combined in one module respectively in this smart system. You can thus ...
Z-4DI-2AI-2DO is a I/O module with 4 digital inputs, 2 analog inputs, 2 relay outputs, slave for Modbus RTU, on two RS485 serial ports. The module allows the possibility to set the parameters via USB (Easy setup software) an registers ...
SENECA | Automation Interfaces
ZE-4DI-2AI-2DO is an I/O module with 4 digital inputs, 2 analog inputs, and 2 digital relay outputs, for slave communication over ModbusTCP-IP (Ethernet) and Modbus RTU. The module has server functionality for the Ethernet communication ...
SENECA | Automation Interfaces
ZE-2AI is an I/O module with 2 analog inputs for slave communication over Modbus TCP-IP (Ethernet) and Modbus RTU. The module has server functionality for the 100 Mbit/s Ethernet communication port with Modbus TCP-IP protocol and can ...
SENECA | Automation Interfaces
The universal Input / Output module UG 9461 has analogue inputs and 2 analogue outputs. It can be used to connect thermocouples and thermistors and offers 2 configurable measuring inputs 0-10V or 0-20mA. Via Modbus the input status can ...
Programmable analog output modules with 2 outputs for FRER Network Analyzers The M52U... modules with 2 or 4 analogue outputs allow, when connected to a FRER multifunctional analyser, to generate up to 12 analogue outputs (using up ...
Programmable analog output modules with 4 outputs for FRER Network Analysers The M52U... modules with 2 or 4 analogue outputs allow, when connected to a FRER multifunctional analyser, to generate up to 12 analogue outputs (using up ...
The PCI-9524 is a robust, multi-purpose module designed for turnkey material test systems (MTS). Equipped with four strain gauge-based transducer input channels, four general purpose analog input channels, and a 3-axis motion controller, ...
Multi I/O is a communications card that helps integrate a control and monitoring system using fully-configurable input and output relay signals. Enables connection of 2 devices to a single UPS communications port. Designed for applications ...
The MV110 AI Series by akYtec offers a comprehensive lineup of analog input modules specifically designed for decentralized automation systems. These modules are adept at facilitating reliable communication through the Modbus RTU/ASCII ...
akYtec GmbH
The MU110 AO Series by akYtec presents a lineup of analog output modules tailored for decentralized automation systems. These modules utilize the robust Modbus RTU/ASCII protocol and an RS485 interface to ensure reliable communication, ...
akYtec GmbH
The MV210 AI Series from akYtec represents a collection of input modules, working through Modbus TCP via Ethernet, expertly designed for precision and versatility in industrial automation systems. This series is tailored to handle a wide ...
akYtec GmbH
OCS-I/O is a modular I/O system for OCS offering a fieldbus network (CsCAN) from the CNX116 base. It is a flexible I/O system that can be applied as a local expansion I/O or as remote I/O distributed over hundreds of meters. The CNX116 ...
Horner Automation
SmartMod+ expandable I/O supporting Modbus TCP/IP communication protocol. Modbus TCP/IP -Traditional slice type I/O -Connects to Ethernet via RJ45 to any XL-Series OCS or other OCS/RCS family controller -DIN rail mountable ...
Horner Automation
SmartBlock a remote I/O solution for any CAN equipped Horner OCS. -Analogue, Digital and Mixed input/output options -5-pin double CsCAN plug -Removable Field Wiring Terminals -Easy-to-read, separate I/O connectors ...
Horner Automation
Front-end intelligence with patented Click&Go control logic, up to 24 rules Active communication with MX-AOPC UA ServerSave time and wiring cost with peer-to-peer communicationSupports SNMPv1/v2c/v3Friendly configuration via web browserSimplify ...
Voltage, current, resistance, potentiometer, RTD, thermocouple, strain gage (full-, half-, and quarter-bridge configuration), IEPE High-accuracy digitization 24-bit ADC, 100 kHz sample rate per channel Status, trigger, tare, ...
Gantner Instruments
measuring half and full bridge, IEPE-sensor, voltage, current, quarter bridge with completion terminal voltage (±10 V) or current (0 - 20 mA), 100 kHz update rate High-accuracy digitization 19-bit SAR ADC, 100 kHz sample rate status, ...
Gantner Instruments
thermocouple (type B / E / J / K / L / N / R / S / T / U), voltage (±80 mV) High-accuracy digitization 24-bit ADC, 100 Hz sample rate per channel, 50/60 Hz mains rejection Automatic linearization correction optimal position ...
Gantner Instruments
• Analogue Input Module • Encoder Input Module • Input Module • Digital Input Output Module • Strain gauge Input Module The Orbit Network can do more than just interface to Solartron digital displacement transducers (Digital ...
Red Lion's rugged E3 I/O™ Ethernet-enabled I/O module platform provides powerful networking and reliable remote monitoring and control capabilities for harsh industrial environments. With all-metal housing, wide environmental specifications ...
Red Lion Controls
The programmable I/O modules of the Saia PCD1 E-Line series with Saia PG5® enable the autonomous and safe operation of the modules even if communication to the master station is interrupted. The local function of a room, for example, ...
The modules in the Saia PCD1.E-Line S-Series for HVAC applications have a mix of analogue and digital inputs and outputs. With 6 to 12 data points per module, they can be combined easily and are an economical addition to the L-Series. ...
The 905U and 805U simply and reliably communicate transducer and switch data by providing a 4-20mA, mV and digital interface in a small footprint radio. The sensor data is transmitted to a remote output as digital and 4-20mA effectively ...
LioN-Link is a modular, decentralized IP67 I/O system for field level applications and is used in situations where machines or plants have distributed I/O concentrations in limited space conditions. LioN-Link consists of bus couplers ...
The Trio CAN16 Output module offers a compact DIN rail mounted output expansion capability for all Trio Motion Coordinators. Up to 16 P317 modules may be connected to the CAN network which may be up to 100m long. This provides 256 distributed ...
Trio Motion Technology
The xtremeBLOCK CANopen module combines many different I/O signal configurations. It offers a total of 12 inputs, eight of which can be parameterized as analog. The remaining four digital inputs can also be configured as frequency inputs ...
Data Panel GmbH
The xtremeDB -1 (pronounced: "dash one") CANopen module combines many different I/O signal configurations. It offers a total of eight inputs, up to four of which can be parameterized in analog mode. Two of the digital inputs can also ...
Data Panel GmbH
The xtremeDB -1 (pronounced: "dash one") SAE J1939 module combines many different I/O signal configurations. It offers a total of eight inputs, up to four of which can be parameterized in analog. Two of the digital inputs can also be ...
Data Panel GmbH
ASi-5 PCB module with integrated IO-Link master, 65 mm x 40 mm, 4 x IO-Link ports with configurable conectors for port class A or Port class B, sensor supply (IO-Link supply and input/output supply) out of AUX, LED, periphery connection ...
Bihl+Wiedemann GmbH
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining