- Robotics - Automation - Industrial IT >
- Automation >
- Analog I/O module
Analog I/O modules
Product Feature: Flexible protocol module and I/O module plug and play, features as below: 1. designed with a max of 64 modules, each I/O module is built with 16 channels and each have LED indicator. 2.supports an overall of 1024 I/O ...
ODOT Automation
ODOT CN-8032 Profinet Network Adapter The CN-8032 Profinet network adapter supports standard Profinet IO Device Communication. The adapter supports MRP media redundancy, and it could realize ring network redundancy. And it supports ...
ODOT Automation
The CN-8033 EtherCAT I/O module supports standard EtherCAT protocol access. The adapter supports a Max. input of 1024 bytes and a Max. output of 1024 bytes. It supports 32 pcs of extended IO modules. Hardware Specification System ...
ODOT Automation
Combined module of digital inputs and outputs with an NPN open collector and a relay. The integrated power supply has enough power even for additional modules on the bus. 8x digital input 4x analogie output, 0…2/5/10/±10 ...
CANopen module with 4 analog Inputs • Resolution: Up to 20 bits • Programmable input voltage range: ±10V • Easy control cabinet wiring due to 3-lead connection • CANopen profiles according to CiA® specification CiA ...
esd electronics gmbh
CANopen module with 8 analog Inputs • 8 A/D-Converter Inputs • Resolution: 14 bit • Input voltage range: ±10.24 V • Sample rate: up to 100 μs / 8 channels simultaneously • CANopen profiles according to CiA® specification ...
esd electronics gmbh
CANopen module with 4 analog outputs • Resolution: 12 bits plus sign • Output voltage range: ±10V • CANopen profiles according to CiA® specification CiA 301 and CiA 401 Approved Reliability and Ease of Use • Electrical ...
esd electronics gmbh
DeviceNet Analog Remote I/O (Terminal Block Type) The ARD-A series analog remote I/O units provide input/output expansion and communication for various devices using DeviceNet protocols. The ARD-A series provides high measurement accuracy ...
Z-4DI-2AI-2DO is a I/O module with 4 digital inputs, 2 analog inputs, 2 relay outputs, slave for Modbus RTU, on two RS485 serial ports. The module allows the possibility to set the parameters via USB (Easy setup software) an registers ...
SENECA | Automation Interfaces
ZE-4DI-2AI-2DO is an I/O module with 4 digital inputs, 2 analog inputs, and 2 digital relay outputs, for slave communication over ModbusTCP-IP (Ethernet) and Modbus RTU. The module has server functionality for the Ethernet communication ...
SENECA | Automation Interfaces
ZE-2AI is an I/O module with 2 analog inputs for slave communication over Modbus TCP-IP (Ethernet) and Modbus RTU. The module has server functionality for the 100 Mbit/s Ethernet communication port with Modbus TCP-IP protocol and can ...
SENECA | Automation Interfaces
The universal Input / Output module UG 9461 has analogue inputs and 2 analogue outputs. It can be used to connect thermocouples and thermistors and offers 2 configurable measuring inputs 0-10V or 0-20mA. Via Modbus the input status can ...
Multi I/O is a communications card that helps integrate a control and monitoring system using fully-configurable input and output relay signals. Enables connection of 2 devices to a single UPS communications port. Designed for applications ...
SmartMod+ expandable I/O supporting Modbus TCP/IP communication protocol. Modbus TCP/IP -Traditional slice type I/O -Connects to Ethernet via RJ45 to any XL-Series OCS or other OCS/RCS family controller -DIN rail mountable ...
Horner Automation
SmartBlock a remote I/O solution for any CAN equipped Horner OCS. -Analogue, Digital and Mixed input/output options -5-pin double CsCAN plug -Removable Field Wiring Terminals -Easy-to-read, separate I/O connectors ...
Horner Automation
SmartMod+ expandable I/O supporting CANopen communication protocol. -Traditional slice type I/O -The CANopen communication protocol allows direct interface with any X-Series OCS or other OCS/RCS family controller -DIN ...
Horner Automation
Front-end intelligence with patented Click&Go control logic, up to 24 rules Active communication with MX-AOPC UA ServerSave time and wiring cost with peer-to-peer communicationSupports SNMPv1/v2c/v3Friendly configuration via web browserSimplify ...
Voltage, current, resistance, potentiometer, RTD, thermocouple, strain gage (full-, half-, and quarter-bridge configuration), IEPE High-accuracy digitization 24-bit ADC, 100 kHz sample rate per channel Status, trigger, tare, ...
Gantner Instruments
measuring half and full bridge, IEPE-sensor, voltage, current, quarter bridge with completion terminal voltage (±10 V) or current (0 - 20 mA), 100 kHz update rate High-accuracy digitization 19-bit SAR ADC, 100 kHz sample rate status, ...
Gantner Instruments
thermocouple (type B / E / J / K / L / N / R / S / T / U), voltage (±80 mV) High-accuracy digitization 24-bit ADC, 100 Hz sample rate per channel, 50/60 Hz mains rejection Automatic linearization correction optimal position ...
Gantner Instruments
• Analogue Input Module • Encoder Input Module • Input Module • Digital Input Output Module • Strain gauge Input Module The Orbit Network can do more than just interface to Solartron digital displacement transducers (Digital ...
Red Lion's rugged E3 I/O™ Ethernet-enabled I/O module platform provides powerful networking and reliable remote monitoring and control capabilities for harsh industrial environments. With all-metal housing, wide environmental specifications ...
Red Lion Controls
The programmable I/O modules of the Saia PCD1 E-Line series with Saia PG5® enable the autonomous and safe operation of the modules even if communication to the master station is interrupted. The local function of a room, for example, ...
The modules in the Saia PCD1.E-Line S-Series for HVAC applications have a mix of analogue and digital inputs and outputs. With 6 to 12 data points per module, they can be combined easily and are an economical addition to the L-Series. ...
The 905U and 805U simply and reliably communicate transducer and switch data by providing a 4-20mA, mV and digital interface in a small footprint radio. The sensor data is transmitted to a remote output as digital and 4-20mA effectively ...
The Trio CAN16 Output module offers a compact DIN rail mounted output expansion capability for all Trio Motion Coordinators. Up to 16 P317 modules may be connected to the CAN network which may be up to 100m long. This provides 256 distributed ...
Trio Motion Technology
ASi-5 PCB module with integrated IO-Link master, 65 mm x 40 mm, 4 x IO-Link ports with configurable conectors for port class A or Port class B, sensor supply (IO-Link supply and input/output supply) out of AUX, LED, periphery connection ...
GF 30% Polyamid 8(12)-32 VDC 1S Li-on Battery -40C +80C 1x IMU Sensor Up to 1 Frequency Input Up to 4 Current Inputs Up to 4 Resistive Inputs Up to 4 High-Side Outputs Up to 4 Low-Side Outputs Up to 1 Analog Output Up to 2 ...
Makersan
GF 30% Polyamid 8(12)-32 VDC 1S Li-on Battery -40C +80C 1x IMU Sensor Up to 1 Frequency Input Up to 4 Current Inputs Up to 4 Resistive Inputs Up to 4 High-Side Outputs Up to 4 Low-Side Outputs Up to 1 Analog Output Up to 2 ...
Makersan
GF 30% Polyamid 5(9)-12 VDC -40C +80C 1S Li-on Battery Up to 1 Frequency Input Up to 4 Current Inputs Up to 4 Resistive Inputs Up to 4 High-Side Outputs Up to 4 Low-Side Outputs Up to 1 Analog Output Up to 2 Solid State Relays
Makersan
Servo/Motor Controller Single-Module Input Range: 0 to +5 V Output Range: 4 to 20 mA Configuration: Single Module The SCM5B392 servo/motor controller module set is designed to solve the problem of extending a servo- or motor-controller ...
The MAQ20-DIOL discrete input/output module has 5 isolated discrete input channels and 5 isolated discrete output channels. Input channels accept 3-60VDC signals and output channels switch 3-60VDC signals at up to 3A load. Discrete ...
The MAQ20-DIOH discrete input/output module has 4 isolated discrete inputs and 4 isolated discrete outputs. Input channels accept 90-280VAC/VDC signals and output channels switch 24-280VAC signals at up to 3A AC load. NOTE: DIOH output ...
Grayhill offers I/O modules in the industry standard sizes of mini, standard and G5. Grayhill also offers its unique Open-Line style I/O module that offers two input/output points per snap-in module. This not only saves space but also ...
The BACnet module BMT-Multi I/0 is a compact and rapidly to install solution to connect digital and analog signals from the actor and sensor level directly to a control unit in building automation via BACnet MS/TP protocol. 29 I/Os, some ...
METZ CONNECT
The BACnet MS/TP module with 4 analog outputs was developed for decentralized switching tasks. It is suitable as encoder for control variables, for example for electrical vent and mixing valves, valve positions, etc. The outputs can be ...
METZ CONNECT
The BACnet MS/TP module with 8 individually configurable resistance or voltage inputs was developed for decentralized switching tasks. It is suitable for detecting resistances and voltages of, for example, passive and active temperature ...
METZ CONNECT
The xtremeBLOCK CANopen module combines many different I/O signal configurations. It offers a total of 12 inputs, eight of which can be parameterized as analog. The remaining four digital inputs can also be configured as frequency inputs ...
The xtremeDB -1 (pronounced: "dash one") CANopen module combines many different I/O signal configurations. It offers a total of eight inputs, up to four of which can be parameterized in analog mode. Two of the digital inputs can also ...
The xtremeDB -1 (pronounced: "dash one") SAE J1939 module combines many different I/O signal configurations. It offers a total of eight inputs, up to four of which can be parameterized in analog. Two of the digital inputs can also be ...
As a communication interface independent of the field bus, the sensors, actuators and I/O supporting the IO-Link protocol are IO-Link slave devices, which greatly improves the reliability of the devices. M12 series classification: - ...
To expand the I/O capability of certain RTCU products an MODBUS compatible I/O module can be connected to the product and configured using the I/O Expansion configuration functionality available in the RTCU IDE. The I/O Expansion is completely ...
LOGICIO
The Ethernet system for pressure measurement MSX-E3311 has 16/8 differential inputs, 24 bit, for the connection of straing gauges and a digital trigger input, 24 V. Up to 8 channels can be acquired simultaneously. The system was developped ...
NXI-5100 series high density programmable resistance card programmable Rresistor module NXI-5100 supports LAN bus control. Its optional range of resistance is 0Ω~11.11MΩ. Resistance accuracy can be up to 0.1%. For different applications, ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining