- Electricity - Electronics >
- Switch and Relay >
- Anti-surge surge arrester
Anti-surge surge arresters
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Voltage: 230, 400 V
Primary current: 100,000, 20,000, 3,000, 12,500, 25,000 A
The 7P Series consists of Type 1 + 2, Type 1, Type 2 and Type 3 surge arresters. These devices include the following features (according to Type): • Single phase systems or three-phase systems • ...
Voltage: 230 V
Primary current: 10 A
IGA TEST protectors cut off the power supply when they detect a permanent overvoltage , (for example, a fault in the neutral), thus protecting the equipment installed downstream. To restore the main circuit breaker, it is necessary ...
Aplicaciones Tecnológicas, S.A.
Voltage: 400, 230 V
Primary current: 25 A
IGA TEST protectors cut off the power supply when they detect a permanent overvoltage , (for example, a fault in the neutral), thus protecting the equipment installed downstream. To restore the main circuit breaker, it is necessary ...
Aplicaciones Tecnológicas, S.A.
Voltage: 400, 230 V
Primary current: 32 A
Open circuit voltage: 275, 400 V
IGA TEST protectors cut off the power supply when they detect a permanent overvoltage , (for example, a fault in the neutral), thus protecting the equipment installed downstream. To restore the main circuit breaker, it is necessary ...
Aplicaciones Tecnológicas, S.A.
Voltage: 440 V
Primary current: 5,000 A
... Network nominal voltage Protection mode Neutral configuration Max. AC operating System - Uc Temporary Over Voltage (TOV) - UT Temporary Over Voltage (TOV) - UT Leakage ...
Indelec
Voltage: 440 V
Primary current: 12,500 A
The Surge Protective Device (or SPD: generic name for any device that protects against voltage surges) is a recognized and effective solution to the overvoltage problem for any of power or telecom, data, ...
Indelec
Voltage: 440 V
Primary current: 30,000 A
The Surge Protective Device (or SPD: generic name for any device that protects against voltage surges) is a recognized and effective solution to the overvoltage problem for any of power or telecom, data, ...
Indelec
Voltage: 120, 230 V
Primary current: 5,000 A
... 2 (or 3) surge protector - In : 5 kA - Imax : 15 kA - Commun/Differential mode - Pluggable module - Remote signaling option - EN 61643-11, IEC 61643-11 and UL1449 ed.4 compliance The DAC15C Type 2 or ...
CITEL
Voltage: 120, 208, 230, 400 V
Primary current: 5,000 A
... type 2 (or 3) surge protector - In : 5 kA - Imax : 15 kA - Common mode/differential - Pluggable module - Remote signaling option - EN 61643-11, CEI 61643-11, UL1449 ed.3 compliance The DAC15C Type 2 ...
CITEL
Voltage: 120, 230 V
Primary current: 5,000 A
Compact single-phase type 2 (or 3) surge protector - 230 V - Monobloc - Cost effective single-phase surge protector - Type 2 or 3 monobloc compact - In/Imax: 5 kA/10 ...
CITEL
Voltage: 400, 230 V
Primary current: 20,000 A
... 2/Class I+II which are designed to protect electrical installations from lightning strikes (10/350 μs) and induced voltage surges (8/20 μs). Ideal for protection upstream of smart-meters (no losses). Features ...
Cirprotec
Voltage: 400, 230 V
Primary current: 50,000, 20,000 A
... 2/Class I+II which are designed to protect electrical installations from lightning strikes (10/350 μs) and induced voltage surges (8/20 μs). Ideal for protection upstream of smart-meters (no losses). Features ...
Cirprotec
Voltage: 400, 230 V
Primary current: 50,000, 20,000 A
... 2/Class I+II which are designed to protect electrical installations from lightning strikes (10/350 μs) and induced voltage surges (8/20 μs). Ideal for protection upstream of smart-meters (no losses). Features ...
Cirprotec
Voltage: 1,000 V
Primary current: 20,000 A - 40,000 A
... 1000 surge arrestor, type 2 surge arrester. Application: · Designed especially for surge protection of the PV strings, apply to the Photovoltaic power grid-connection ...
Britec Electric Co., Ltd
Voltage: 150, 275, 320 V
Primary current: 12,500 A
... / 320V can be achieved. Protection class: Type 1+2 , Class I+II. Pole number:1P,2P,3P,4P,1+1NPE,3+1NPE. BR-12.5M 1P surge arrester is suitable for single phase TN system.
Britec Electric Co., Ltd
Voltage: 275 V
Primary current: 20,000 A - 50,000 A
Open circuit voltage: 1.3 kV
Features: Designed accordingly to IEC standard. This spd is module design, nice sealing performance, matched remote signal interface and faulty indicator window, installed in 35mm DIN rail, easy to wire. There has temperature control ...
Britec Electric Co., Ltd
Voltage: 220 V
Primary current: 12,000 A
Lightning and surge arrester for single lines (F+N) 220 V. Type 2 (Class C) protector, suitable for protection of low voltage lines against lightning strikes and transitory surges ...
Voltage: 380 V
Primary current: 12,000 A
Lightning and surge arrester for three phase lines (3F+N) 220 V. Type 2 (Class C) protector, suitable for protection of low voltage lines against lightning strikes and transitory surges ...
Voltage: 150 V - 615 V
Primary current: 40,000, 20,000 A
... monitoring surge protector, is consist of new designed surge protector with temperature monitoring part inside - iSPD-20C, and intelligent monitoring module - iSPD-M, which are awarded ...
Voltage: 150 V - 615 V
Primary current: 40,000, 20,000 A
... monitoring surge protector, is consist of new designed surge protector with temperature monitoring part inside - iSPD-20C, and intelligent monitoring module - iSPD-M, which are awarded ...
Voltage: 1,000, 1,060 V
Primary current: 20,000, 40,000 A
-C/D mode 1000Vdc surge protector. -The core parts are metal oxide vristor components with high discharge capacity. -With Reliable control thanks to Thermo Dynamic Control disconnector. -Without remote signaling contact ...
Voltage: 1,000, 600, 200 V
Primary current: 20,000, 900, 2,400, 1,600, 3,200 A
Voltage: 120 V
Primary current: 15, 20 A
Open circuit voltage: 400 V
... outlet rack-mounted surge protector that provides superior surge protection in a compact 1U enclosure. The RackPro range is constructed with an all-steel case and designed with competitive ...
Voltage: 120 V
Primary current: 15 A
Eaton Eclipse surge suppressors offer total protection against power surges, power spikes, lightning and line noise. Suitable for home offices, networked workstations, PC servers and ...
Powerware
Voltage: 230, 400 V
Primary current: 40,000, 20,000 A
... is surge in power grid due to indirect and direct lightning or other instant over voltage, the electrode will breakover within nanosecond grade time, to lead the surge to earth, and protect the electric ...
Overvoltage Protection: Power frequency overvoltage protection
Voltage: 120, 240 V
SURGE PROTECTIVE DEVICE, 6-MODE, 120/240 VAC 1PH, TYPE 1 OR TYPE 2, INDOOR METAL, CONNECTED EQUIPMENT WARRANTY 10YR $25,000 Intermatic's Smart Guard® Whole House Surge Protective Device provides coverage ...
Grässlin by Intermatic
Voltage: 275 V - 550 V
Primary current: 5,000 A - 100,000 A
Surge Protective Device SPD Application • Number of poles: 1, 2,3, 4; • Electric ratings: 230/400V, AC50/60Hz; • Application: Protect electric system and on-loading electrical apparatus from thunder and instantaneous ...
... control systems Pepperl+Fuchs‘ surge protection modules reliably divert surges and currents to ground and protect people and machines against possible negative consequences. Our product range provides ...
Voltage: 3, 20 kV
... are connected to the terminal block signal, power and earth terminals. Hazardous Area Certifications The TP series surge protectors are certified to numerous worldwide approval standards for hazardous ...
Voltage: 0 V - 5 V
Primary current: 5,000 A
... various interferences caused by the common ground transmission signal -The excellent lightning protection performance, built-in multi-level surge protection, large surge ...
3onedata Co.,Ltd.
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining