- Materials - Tools - Components >
- Standard Mechanical Component >
- Armored cable cable gland
Armored cable cable glands
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

Operating temperature: -60 °C - 130 °C
The E1FW cable gland is a brass cable gland specifically for cables with steel-wire armouring (SWA). The E1FW provides a pressure-proof seal for the ...
ROSE Systemtechnik

Clamping range: 10.5 mm - 50.5 mm
Operating temperature: -40 °C - 150 °C
... Compression part: Nickel Plated Brass Gland body: Nickel Plated Brass O-ring: NBR Connection thread: Metric (EN60423) Properties: - Ship building - Off shore - Wind power plant - For armoured cables - ...
ORTAC

Operating temperature: -60 °C - 180 °C
... compression gland) Certificate: PT-CE-Rohs-ISO9001-14001-Ohsas 18001 Material: MS58 brass with or without nickel plated stainless steel AISI303 / 316L / Aluminium Standards: EN 60079-0:2012, 60079-1:2007, 60079-31:2009 Cable ...
ORTAC

Operating temperature: -60 °C - 180 °C
... compression gland) Certificate: PT-CE-Rohs-ISO9001-14001-Ohsas 18001 Material: MS58 brass with or without nickel plated stainless steel AISI303 / 316L / Aluminium Standards: EN 60079-0:2012, 60079-1:2007, 60079-31:2009 Cable ...
ORTAC

Cable diameter: 5.5 mm - 103 mm
Thread diameter: 20 mm - 115 mm
Operating temperature: -60 °C - 100 °C
... 4、Thread: Metric thread is standard, NPT thread and G thread are optional 5、Single seal, suitable for both armored and unarmored cable Technical Parameters: 1、Explosion-proof mark: ...

Cable diameter: 4 mm - 90 mm
Thread diameter: 20 mm - 115 mm
Operating temperature: -60 °C - 100 °C
... 4、Thread: Metric thread is standard, NPT thread and G thread are optional 5、Single seal, suitable for both armored and unarmored cable Technical Parameters: 1、Explosion-proof mark: ...

Cable diameter: 3.4 mm - 90 mm
Thread diameter: 20 mm - 100 mm
Operating temperature: -20 °C - 85 °C
Features: Typical examples LIGHT&SOUND combinations a new standard ATEX with terminals box.

Cable diameter: 4 mm - 78 mm
Thread diameter: 27 mm - 100 mm
Operating temperature: -40 °C - 100 °C
The ATEX II2GD model is a liquid-tight strain relief cable gland that is either fabricated from brass or stainless steel. Designed for use in indoors possessing high humidity, it is an ideal cable ...

Cable diameter: 4 mm - 92 mm
Thread diameter: 0.5 in - 4 in
Operating temperature: -40 °C - 100 °C
Cable glands for indoor dry dusts not chemically corrosive to the armor of the cable. Seal on the internale cable insulation under armour Materials: Brass - Brass ...

Cable diameter: 5.5 mm - 104.5 mm
Thread diameter: 0.5 mm - 4 mm
Operating temperature: -80 °C - 60 °C
... IECEx glands for armoured cables. the gland is designed to provide armour clamping by using one clamping arrangement for all armour/braid types. it also provides the cables ...

Operating temperature: -60 °C - 80 °C
... suitable for single wire armour ‘W’, wire braid ‘X’ and tape armour ‘Z’. Suitable for both elastomer and plastic insulated cables, and particularly for cables which exhibit ...
Hawke International U.K

Cable diameter: 6 mm - 110 mm
Thread diameter: 16 mm - 120 mm
Operating temperature: -40 °C - 125 °C
Industrial Brass Cable Glands. Double Compression Gland, Single Compression Glands. Type A2 Glands, Type BW Glands, Type CW Glands, ...

Cable diameter: 5 mm - 104 mm
Thread diameter: 16 mm - 110 mm
... in suitable for clamping and fixing steel wire knit of armored cable, it is cable core and enclosure gas sealing protection most be lP66 Function: Suitable for clamping ...
YUEQING JIXIANG CONNECTOR CO., LTD

Cable diameter: 15.8 mm - 82.9 mm
Operating temperature: -60 °C - 200 °C
BW Industrial Cable Gland • High quality durable materials • Simple, effective two part arrangement • Direct & remote installation • Permanently crimped, low impedance earth termination • ...
CMP Products

Cable diameter: 10 mm - 126 mm
Thread diameter: 0.5 in - 4 in
Operating temperature: -60 °C - 180 °C
Cable glands for armoured, lead sheathed cables Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) ...

Cable diameter: 3 mm - 80 mm
Thread diameter: 3 mm - 72 mm
Universal Exe and Exd Cable Glands for armored cables (ATEX and IECEx) These universal Exd/ Exd cable glands are suited for (SWA) ...
Your suggestions for improvement:
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining