Primary current: 5 A
Voltage: 24, 110, 230 V
Safety slave Low coded according to ISO 14119 (type 2) Interlock switch for safety doors and protective hoods Spring force (closed-circuit current) type F and magnetic force (working current) type M Status display ...
BERNSTEIN AG
Primary current: 10 A
Voltage: 240 V
Safety slave Rope-pull switch in metal housing AS-i status display Tensioned length up to 75 meters (version 300) (37,5 meters version 175) Quick-Fix quick action clamping head QF available
BERNSTEIN AG
Primary current: 10 A
Voltage: 240 V
Safety slave Low coded according to ISO 14119 (type 2) Safety switch with separate actuator Slim and short switch design AS-i status display Plastic housing Rotary head in 90° steps 2 actuating entries
BERNSTEIN AG
Primary current: 10 A
Voltage: 240 V
Safety slave Low coded according to ISO 14119 (type 2) Safety switch with separate actuator AS-i status display Plastic housing Variable actuator with two actuator openings
BERNSTEIN AG
With closed-circuit current or open-circuit current principle Rotatable actuating head made of metal Mechanical release on the front Particularly space-saving design Suited for applications up to Performance Level PL d
Reliable protection of extensive hazardous areas For use on conveyor systems Robust design for use in harsh industrial environments Easy setting of the rope tension Integration into AS-i networks
Primary current: 50 mA
Voltage: 24 V
Operating temperature: -20 °C - 60 °C
• Locking force up to 1000 N • Up to category 4 / PL e according to EN ISO 13849-1 • Actuating force 26 N • Extraction force 18 N • Auxiliary release • Unicode Open-circuit current principle: guard locking by control of AS-i output ...
EUCHNER GmbH + Co. KG
Primary current: 50 mA
Voltage: 24 V
Operating temperature: -20 °C - 55 °C
Safety switch CET-AS – with AS-i connection, closed-circuit current principle, with wire front release (bowden) 4 m • Safety switch with guard locking and integrated evaluation electronics • Locking force up to 6,500 N • Category 4 ...
EUCHNER GmbH + Co. KG
Primary current: 1 mA
Voltage: 24 V
Operating temperature: -20 °C - 80 °C
• Auxiliary release on the front • Escape release from the rear • With door monitoring contact Solenoid operating voltage AC/DC 24 V +10%, -15% Guard locking type STA3 Closed-circuit current principle, guard locking by spring ...
EUCHNER GmbH + Co. KG
Primary current: 4 A
Voltage: 4 V
Operating temperature: -20 °C - 80 °C
• Cable entry M20 x 1.5 The safety switch NX without guard locking is the counterpart to safety switch TX with guard locking. Both safety switches have the same actuator. In this way, a system can be operated using safety switches with ...
EUCHNER GmbH + Co. KG
Primary current: 4 A
Voltage: 230, 24 V
Operating temperature: -20 °C - 80 °C
• Cable entry M20 x 1.5 The safety switch NX without guard locking is the counterpart to safety switch TX with guard locking. Both safety switches have the same actuator. In this way, a system can be operated using safety switches with ...
EUCHNER GmbH + Co. KG
Primary current: 4 A
Voltage: 24, 230 V
Operating temperature: -20 °C - 80 °C
• Cable entry M20 x 1.5 • LED indicator The safety switch NX without guard locking is the counterpart to safety switch TX with guard locking. Both safety switches have the same actuator. In this way, a system can be operated using safety ...
EUCHNER GmbH + Co. KG
You can use safety switches with a separate actuator to monitor protective isolating devices on sliding doors, swing doors or detachable paneling, for example. These safety switches are also available with guard locking to actively prevent ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining