- Metrology - Laboratory >
- Analytical Instrumentation >
- Calibration analyzer
Calibration analyzers
Since the launch of the first generation in 2010, GRYF OXY Z stands for the most reliable and endurant Zirconia oxygen analyzer on the market. The second generation combines the exceptional features of its predecessor ...
GRYF
AXR Scientific Terra600M, a fast, accurate, and easy-to-use handheld XRF mining analyzer designed for different analytical applications in the mining industry. The Terra600M provides on-site analysis of ore samples with ...
... depending upon your needs Can be used on any breathing air compressor Digital display ACG+ Front Display Sample/Calibration gas inlet Gas outlet for timed sample support (section 5.17) Gas inlet/purge valve External ...
Chlorine dioxide Analyser Measuring range: 0 – 1 mg/l 3 measuring electrodes platinum/platinum + reference electrode Continuous measuring: chlorine dioxide Measuring range for concentrations up to ...
... power switch, intelligent management of battery power, to avoid the instrument working under low power conditions 6. Calibration menu and alarm value setting are controlled by password to prevent misoperation 7. ...
... or manual temperature compensation . Several calibration methods available . 4 individually password protected . Datalog with time and date stamp . Intelligent measurement,auto judge as calibration ...
Compact design Low detection limit Flame proof enclosure LaserGas™ III SP is the third generation in-situ analyzer, designed for safety applications with a special focus on SIL-applications and Ex-d. A compact sized ...
Online measurement system for continuous monitoring of oxygen content in hot process water With O2 – Control the residual oxygen content of process water in the range of 0.001 mg/l to 0.5 mg/l can be monitored continuously. In a bypass ...
OFS Online Fluid Sensoric GmbH
Fixed gas analyser suitable for use in potential hazardous areas, with-in biogas, landfill and bio-methane applications Benefits: - Fully ATEX certified for use in ZONE 2 Areas - Continuous monitor system - ...
... determined in individually defined measurement cycles. The following reasons speak for the use of the GMC Biogas 08 biogas analyzer from Bieler + Lang: • Double infrared measuring bench for CH4 and CO2 • H2S sensor ...
GasEye C2H2 is a high performance in-situ acetylene analyzer. Suitable for safety applications and process control. 24/7 continuous operation. No sample preparation. No zero drift. No field calibration. ...
... supply, separated serial ports for printer and PC. Three calibration channels are available. Standard calibrations for milk analyzer LACTOMAT BiSonic are for Cow milk, Sheep milk, ...
Milkotester
... used for storing LOG files of the events. Programming keypad with 5 bubble-keys with CAL Key for direct access to the Calibration menu GRAPH/USB Key for direct access to the Measure graphs and for data download to ...
CHEMITEC
Real-time process NIR analyzer: accurate and continuous measurements for process optimisation and quality control in the plant. PROCESS NIR ANALYZER FOR REAL-TIME MONITORING Visum NIR In-Line™ is ...
... points. proCAL and automatic calibration The proCAL method developed by PRONOVA enables even greater long-term stability for methane and carbon dioxide measurements. Thanks to additional automatic one-point calibration ...
... market. High Accuracy Temperature control ensures reading stability across the operating temperature range. Regular air calibration to optimise long-term stability. Pressure compensation to provide accurate readings ...
... standardise production to make the most of raw materials, reduce risk of human error with minimal sample preparation and minimise calibration management. Sample type Cheese, butter, spreads, fermented and cultured ...
FOSS
... Performing mass measurement, based on the recognized principle of hang-down balances • A convenient and efficient temperature calibration system • Compact design, space efficient for all laboratories • Powerful and intuitive ...
Envira's configuration of the GC 5000 BTX has been specifically designed for the measurement of organic compounds in air, in the range of C4 to C12. It is capable of measuring at ppt levels. It is the perfect choice for industrial applications ...
Process gas analyzers for O2, O3, CO2, H2 and N2 This process analyzer complements Dextens O2, O3, CO2, H2 and N2 sensors. It continuously measures the gas concentration, the temperature, and provides ...
... excellent compatibility with gas streams containing any level of CO2 gas. No routine sensor maintenance is needed Key Analyzer Features User Selectable Range From 0-5 PPM to 25% Output Locking on Selected Range 4-20 ...
AST - Applied Sensing Technologies
The DairyQuant solutions are designed to deliver fast and accurate results for parameters commonly required in dairy process and quality control. The exceptional spectral performance of the DairyQuant solutions means that analysis of ...
The plug-and-play, compact and portable NeoSpectra Puck is the perfect analyzer for model developers and researchers to test applications and collect spectra to build new prediction models. The NeoSpectra Puck provides ...
... way serial communication for use in power quality trend monitoring. The model expands usability by including transducer calibration and timer features. Model 931A, featuring PowerDSA™ Digital Signal Analysis, measures ...
The monitoring sub station should be built in the near sample source (discharge or channel) position to reduce delay analysis.The monitoring sub station area should be greater than 10 m 2 。The instrument was placed on the ground should ...
EIT Solutions Co., Ltd
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining