- Detection - Measurement >
- Electrical Measurements >
- Calibrator
Calibrators
Temperature: 40 °C - 375 °C
Voltage: 234 V
Universally applicable and portable Blockcalibrator for immersion-and insertion probes (e.g. Pt 100, Thermocouples) between +40...375°C • Large measuring range +40 ... 375 ° C • 230 VAC power supply • 120mm immersion depth Various ...
Temperature: 18 °C - 28 °C
Epsilon’s very high resolution calibrator features 20 nanometers (0.8 microinches) resolution and has 50 mm (2 inches) of measuring range. The 3590VHR calibrator meets the accuracy and resolution requirements ...
Epsilon Technology
Temperature: 18 °C - 28 °C
Epsilon’s standard calibrator features 0.001 mm (50 microinches) resolution and has 50 mm (2 inches) of measuring range. The autozero button and digital display greatly simplify calibration of extensometers. The 3590 ...
Epsilon Technology
Temperature: 18 °C - 28 °C
Epsilon’s axial/torsional calibrator features 0.001 mm (50 microinches) resolution, and has 50 mm (2 inches) of measuring range axial and torsional rotation where 1.27 mm (0.050 inch) of linear motion equates to 1° angle ...
Epsilon Technology
Temperature: 10 °C - 35 °C
Voltage: 24 V
The MicroCal automated pressure transducer calibrator is used as a stand-alone calibration standard for differential and gauge pressure sensors found in critical environments. Setra partnered with NASA to develop the ...
- API SwivelCheck is light-weight & comes with a convenient carrying case to easily transport & install on a variety of CNC machines. - Swivelcheck is the only tool that can be mounted off rotating axis center to measure swivel axes ...
Voltage: 0 V - 2 V
Features: * Oyster case with flip-up display is ideal for handheld or benchtop applications * Large 3-1/2 digit LCD display and touch keypad * Display readings in mA or as a % of the 0 to 24mA range or as mV in voltage ranges ...
Extech
Temperature: 30 °C - 650 °C
Voltage: 100 V - 240 V
CS650 Temperature calibration source freely adjustable from +30°C to+ 650°C (0.1°C resolution ) featuring 11 probe holes ( different diameters ). Check the accuracy of your thermometer/probes quickly and easily in house. Ideal for all ...
Overview: Multi-Gas calibrator is a high precision gas analyzer calibrator for atmospheric online monitoring and industrial control on-site online analysis. It is a precision gas calibration instrument ...
The SpeedMaster™ is manufactured by Go4B, and is a speed switch calibration and testing device with pulse pilot. It is the only device that accurately tests the calibration of a speed switch, and permits testing of the 10% alarm and 20% ...
The ADB Sensor Tester is a hand held unit perfectly suited for field testing of 4B adjustable depth bearing (ADB) temperature sensors, as it is equipped with an integrated heating block, designed for direct insertion of sensors. Once ...
Temperature: 0 °C - 40 °C
SCAL2 Handheld AE Calibrator are designed and developed for the requirements of acoustic emission detector calibration. It can export various standard parametric signals like amplitude, rise time, counts and duration. ...
Temperature: 5 °C - 50 °C
Voltage: 220, 110 V
The BL765 is a bench-top humidity generator for calibrating a large workload of probes in the laboratory or on site in the field. The system comprises a humidity and temperature controlled chamber that can house up to six humidity sensors. ...
Balun Technology Co., Ltd
Temperature: -196 °C
The BL631 liquid nitrogen comparison calibrator is specially designed to calibrate standard platinum resistance thermometers (SPRT) and other temperature probes in extreme cold temperature. With the ability to calibrate ...
Balun Technology Co., Ltd
Temperature: -80 °C - 105 °C
Liquid calibrationbaths are the most stable and uniform temperature sources for doing calibration comparison of temperature probes and sensors in a laboratory. They use a large fluid mass to maintain a stable and uniform test environment ...
Balun Technology Co., Ltd
Temperature: -10 °C - 50 °C
Pressure: 65,000 Pa - 108,000 Pa
The 4011 is a sound calibrator conforming to IEC 60942 class 1 and ANSI S1.40 for the calibration and the verification of microphones and sound level meters. It generates a sound pressure level of 114 dB at a frequency ...
Temperature: -10 °C - 50 °C
Pressure: 65,000 Pa - 108,000 Pa
Noise level: 114 dB
Temperature: -10 °C - 50 °C
Pressure: 65,000 Pa - 108,000 Pa
The 4010 is a sound calibrator conforming to IEC 60942 class 1 and ANSI S1.40 for the calibration and the verification of microphones and sound level meters. The combination of two sound pressure levels and two ...
... 3.5 digit LCD display to show a clear, high resolution display of the flow rate. The excellent viewing angle allows the calibrator to be mounted anywhere and still be visible by the operator. Shut-off valve Rather ...
... Pressure & Flow Calibrator In calibration mode the FCO560's multiple sensor configurations allow different external references to be used quickly and simply. When combined with laminar flow elements, the FCO560 may be ...
Pressure: 0 Pa - 44,000 Pa
- A unique primary standard for low-pressure scenarios - Pressure calibration range from 0.001 Pa to 44k Pa - Typical uncertainty of ± 0.005 % reading + 0.02 Pa - Used worldwide in national & accredited laboratories - ...
... range. A switch can be used to switch between the two frequencies. The calibrator's transmission power is freely selectable in 5 dB steps from -85 dBm to -40 dBm. The CR 4000 calibrator can also be operated ...
Product introduction The TC testing instrument is made of aluminum-titanium alloy and ultra-high-strength alloy materials. It is manual control + digital display output, and can detect torque in both directions. It is widely used ...
TianYuDa Precision Machinery
The TC testing instrument is made of aluminum-titanium alloy and ultra-high-strength alloy materials. It is manual control + digital display output, and can detect torque in both directions. It is widely used in occasions requiring strict ...
TianYuDa Precision Machinery
MDJ series dual-range torque wrench tester is a test instrument used for calibrating various torque wrenches. The instrument adopts single-chip control technology and is composed of high-precision torque sensor and force support. Its ...
TianYuDa Precision Machinery
Temperature: 40 °C - 375 °C
The LHC 75 dry block temperature calibrator is a compact and lightweight device, suitable for all conditions and applications, covering different types of industries. The LHC 75 calibrator is the most ...
Leyro Instruments
Temperature: -35 °C - 165 °C
The Leyro Portable dry block temperature calibrator suitable for temperature calibrations, between -35ºC ... 165ºC *, offers a versatile solution for calibrating thermocouples and RTD's in industrial ...
Leyro Instruments
Temperature: 40 °C - 450 °C
The LHC 400 Basic dry block temperature calibrator is a lightweight and compact device, suitable for all conditions and applications, covering different types of industries. The LHC 400 calibrator is ...
Leyro Instruments
Temperature: 0 °C - 50 °C
Pressure: 0 bar - 700 bar
Voltage: 3 V
The HPX High Pressure Calibrator is a high precision calibration tool for pressures between 0 bar and 700 bar. Additional functions such as zero point reset, peak and minimum pressure value indication and leakage measurement ...
Process Calibrator CL-327A general characteristics: 1, The basic accuracy of the output of up to 0.02%, the output is displayed as 6 digit 2, The output functions: DC voltage, DC current, ohms, analog transmitters, ...
Tecpel Co., Ltd.
The CL 325 multi-functional process calibrator from Tecpel is equipped with a beeper warning when output is open (mA) or short (mV,V). It features K, J, E, T Thermocouple in °C and °F, easy key-pad operation, and easy ...
Tecpel Co., Ltd.
The CL-420B is a handheld, programmable calibrator for measurement and signal output. It's great for measuring tiny currents and voltage signals, and it can power sensors while checking their returned current signals. Mainly ...
Tecpel Co., Ltd.
The G.R.A.S. 42AB Sound Calibrator is a small battery-operated precision microphone calibrator. The calibrator can be used directly on 1" microphones and ½" microphones. Adapters for ...
G.R.A.S. Sound & Vibration
Calibration Target Micro V1 Optical calibration and resolution testing are critical metrics in understanding and optimizing any optical system. Calibration Target Micro V1 is unique in that it combines very useful resolution data, ...
The stage micrometer from Opto in the form of a microscope slide is required for the calibration of microscopes. - Glass scale 50 mm in 0.1 mm and 0.01 mm - Calibration of measurement software The stage micrometer is also available ...
Opto's Particle Test Target allows the calibration of measurement functions in microscopes through objects in different forms and sizes or of resolution of an optical system measured in Line Pairs per mm. It is used in the field of Residual ...
Temperature: 0 °C - 50 °C
Voltage: 0 V - 24 V
Process / Loop calibrator (current 0-24mA / voltage 0-24V) • Current source: 4-20mA, 0-20mA, 0-24mA • Voltage source: 4-20V, 0-20V, 0-24V • Basic accuracy: 0,025% • Ramp function in current and voltage source • ...
Voltage: 24, 30 V
Temperature: 10 °C - 50 °C
Voltage: 85 V - 264 V
... chilled mirror reference instrument Transportable to allow on-site calibrations The OptiCal is a premium, self-contained calibrator for humidity sensors. It features an integrated chilled-mirror reference which enables ...
Process Sensing Technologies
Temperature: -5 °C - 60 °C
• Generates stable humidity 2…99 % RH and temperature conditions (<±0.1 %RH, <±0.01 °C) • Humidity and temperature changes in less than 5 min • Time-saving multiply probes calibration • User programmable calibration sequence with up to ...
Process Sensing Technologies
Temperature: -100 °C - 20 °C
Voltage: 100 V - 240 V
Complete dew-point calibration solution with optional compressor, dryer, dew-point generator, reference instrument and optional manifold Generated output responds quickly to a change of set point Stable humidity generation Simple operation ...
Process Sensing Technologies
Temperature: 10 °C - 50 °C
Voltage: 0 V - 5 V
... Edgetech Instruments field proven chilled mirror sensor technology A completely self-sufficient and portable humidity calibration system Temperature and relative humidity controlled independently for custom humidity ...
Voltage: 0 V - 1,000 V
... the world’s first ultra-portable full-function calibrator. Transmille have applied their expertise in designing bench and transportable calibrators to create a new generation of multifunction calibrators ...
TRANSMILLE
Voltage: 0 V - 1,000 V
PRECISION MULTIPRODUCT CALIBRATOR • 0 – 1000V DC / AC Voltage • 0 – 30A DC / AC Current • 0 – 1 GOhm Resistance • 1nF – 10mF Capacitance • 1Hz – 10MHz Frequency • Range of external accessories ...
TRANSMILLE
Voltage: 0 V - 20 V
... The 33XXA Series multiproduct calibrators are modular versions of the class leading 3000A Series Calibrators. Designed to reduce cost, the 33XXA Series feature 0 – 20V DC output as standard with a wide ...
TRANSMILLE
Temperature: -10 °C - 50 °C
Pressure: -1 bar - 4,200 bar
Voltage: 0 V - 15 V
AOIP
Temperature: -270 °C - 2,310 °C
Pressure: 0 bar - 1,000 bar
Voltage: 100 mV - 50,000 mV
CALYS 1000 is a field documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, ...
AOIP
Temperature: -250 °C - 2,310 °C
Pressure: 0 bar - 1,000 bar
Voltage: 100 mV - 50,000 mV
CALYS 1200 is a field documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, ...
AOIP
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining