Primary current: 0 mA - 250 mA
Voltage: 0 V - 100 V
Diameter / length: 43.3 mm
Thermoplastic enclosure Non-contact safety switch Does not protrude into the door opening 119,5 mm x 140 mm x 43,3 mm Substitutes door-handle and safety switch, ...
Primary current: 100 A
Voltage: 0.8 kV
Diameter / length: 35 mm
... Electronic contact-free, coded system Misaligned actuation possible 27 mm x 108.2 mm x 35 mm High repeat accuracy of the switching points Max. length of the sensor chain 200 m 2 short-circuit ...
Voltage: 24 V
• Guard locking suitable for process protection only • Series connection possible • Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB • Short circuit monitoring • 2 safety ...
EUCHNER GmbH + Co. KG
Primary current: 20.4 A - 26.4 A
Voltage: 24 V
• Guard locking suitable for process protection only • Series connection possible • Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB • Short circuit monitoring • 2 safety ...
EUCHNER GmbH + Co. KG
Primary current: 20 mA - 50 mA
Voltage: 24 V
Operating temperature: -20 °C - 60 °C
... suitable actuator is detected by the switch. Guard locking operated by means of input signal. This type of guard locking has a function to prevent persons from unintentionally locking themselves inside if the ...
EUCHNER GmbH + Co. KG
Primary current: 20 mA - 50 mA
Voltage: 24 V
Operating temperature: -20 °C - 60 °C
... suitable actuator is detected by the switch. Guard locking operated by means of input signal. This type of guard locking has a function to prevent persons from unintentionally locking themselves inside if the ...
EUCHNER GmbH + Co. KG
Primary current: 1 mA - 50 mA
Voltage: 0 V - 1 V
Operating temperature: -20 °C - 55 °C
• Guard locking suitable for process protection only • Short circuit monitoring • 2 safety outputs (semiconductor outputs) • Up to category 4 / PL e according to EN ISO 13849-1 • With plug connector ...
EUCHNER GmbH + Co. KG
Primary current: 1 mA - 50 mA
Voltage: 24 V
Operating temperature: -20 °C - 55 °C
• Safety switch with guard locking and integrated evaluation electronics • Guard locking suitable for process protection only • Short circuit monitoring • 2 safety ...
EUCHNER GmbH + Co. KG
Primary current: 1 mA - 100 mA
Voltage: 5 V - 24 V
Operating temperature: -20 °C - 55 °C
• Up to 20 switches in series • Short circuit monitoring • 2 safety outputs (semiconductor outputs) • Up to category 4 / PL e according to EN ISO 13849-1 • With 2 plug connectors M12 • Multicode • ...
EUCHNER GmbH + Co. KG
Primary current: 1 mA - 150 mA
Voltage: 0 V - 1 V
Operating temperature: -20 °C - 55 °C
... monitoring output • Approach directions A, B and C (delivery state) Unicode evaluation Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can ...
EUCHNER GmbH + Co. KG
Primary current: 1 mA - 50 mA
Voltage: 24 V
Operating temperature: -20 °C - 55 °C
• Up to 20 switches in series • Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB • Short circuit monitoring • 2 safety outputs (semiconductor outputs) • Closed-circuit ...
EUCHNER GmbH + Co. KG
Primary current: 80 mA - 350 mA
Voltage: 24 V
Operating temperature: -20 °C - 55 °C
... • 2 safety outputs (semiconductor outputs) • Up to category 4 / PL e according to EN ISO 13849-1 for door position monitoring • With plug connector M12 • Unicode • Door monitoring output Unicode evaluation Each ...
EUCHNER GmbH + Co. KG
Primary current: 2 A
Voltage: 24 V - 48 V
... total safety management without an external controller Electrical locking key with position contact • Level of performance without an external controller: PL = d • Level of performance with AWAX controller: ...
COMITRONIC - BTI
Voltage: 24 V
MASSIMOTTO X5 - Safety Switch for single or double-wing doors Position control for doors / casings on hazardous machinery Contactless encoded electronic sensor with relay Category 3 total safety ...
COMITRONIC - BTI
Voltage: 12 V - 24 V
OPTO2S - Miniature safety Switch Position control for doors / casings on hazardous machinery Contactless encoded electronic sensor with relay Category 3 total safety management without ...
COMITRONIC - BTI
Primary current: 2 A
Voltage: 250 V
The Furtif 3SSR24V model, manufactured by Comitronic, is a stand alone coded non contact safety switch that features an ACOTOM® code. This device is available in 4SSR24BX and 5SSR24BXUS ...
COMITRONIC - BTI
Primary current: 250 mA
Voltage: 24 V
... non-contact and coded safety switch designed with a high switching ability. It is coded with ACOTOM® and features a LED quality display of the accurate code identification. ...
COMITRONIC - BTI
Primary current: 250 mA
Voltage: 24 V
Non-autonomous contactless safety switch Position control for doors / casings on hazardous machinery Contactless coded electronic sensor Total safety management ...
COMITRONIC - BTI
Primary current: 250 mA
Voltage: 24 V
Operating temperature: -25 °C - 60 °C
Safety Switch with serialization Position control for doors / casings on hazardous machinery Contactless coded electronic sensor Total safety management with an ...
COMITRONIC - BTI
Primary current: 250 mA
Voltage: 24 V
Operating temperature: -20 °C - 60 °C
Miniature non-autonomous safety switch Position control for doors / casings on hazardous machinery Contactless coded electronic sensor Total safety management with ...
COMITRONIC - BTI
Primary current: 250 mA
Voltage: 24 V
Operating temperature: -20 °C - 60 °C
Cylindrical safety sensor M18 Position control for low-play doors / casings on hazardous machinery Contactless coded electronic sensor Total safety management with an AWAX controller Cylindrical ...
COMITRONIC - BTI
Operating temperature: -30 °C - 50 °C
... controller: up to PL = e Safety category: up to 4 (EN 954-1) with AWAX controller Time to dangerous failure: MTTFd = 40 years • Max activation distance: up to 24 mm • Security contact/diagnostics: ...
COMITRONIC - BTI
... Compatible to EN418 required with emergency stop *button on the surface cover *the switch works in two direction:tripped when the wire *is pulled or breaking. *The switch can be with indicator light to ...
... rating making it suitable for CIP and SIP processes. Non contact rfid coded safety switches – Gate Locking – Hygienic Locking Switch – IP69k Safety ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining