- Electricity - Electronics >
- Electronic Component >
- Conditioning amplifier
Conditioning amplifiers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Voltage: 10 V
... noise, high gain, and high slew rate make the SIM983 a very convenient tool for sensitive analog signal conditioning. The SIM983 Scaling Amplifier provides fine adjustable gain and offset control for ...
Frequency: 0 Hz - 20,000,000 Hz
The EL-LNA-2 is a 2-channel amplifier manufactured by Elsys. It is designed for any 3rd party data acquisition system. The amplifier offers an option between two gain stages of x10 and x100, both with ...
Voltage: 105 V - 240 V
... as: The modular amplifier cards are designed to operate with every probe diameter configuration and several sensitivity ranges by simple recalibration. For applications that require use of multiple sensors, the ...
Voltage: 0 V - 300 V
Current: 0 A - 10 A
Dual Trip Amplifiers 2002ALM The 2002ALM family of trip-amplifiers can accept a wide range of inputs including 4-20mA, thermocouple, RTD and voltage types • Wide range of configurable inputs • Configurable ...
Voltage: 230, 110, 24 V
Current: 6 A
Frequency: 60, 50 Hz
The VNR21.22 control units are designed as interface for conductive level probes SL series. These electronic units are used to control liquids that have a minimum electrical conductivity of 1 S. The system is based on measurement ...
Frequency: 0 kHz - 200 kHz
... signals (1000000pC) Dynamical properties Time constant Short, Long Operation and installation Device usage Signal conditioning
Kistler
Voltage: 2 V
Current: 1 mA
Frequency: 0 kHz - 10 kHz
... Certificates and Standards Degree of protection EN 60529 IP40 Operation and installation Device usage Signal conditioning Interfaces Dimensions and materials Casing material Plastic
Kistler
Voltage: -10 V - 8 V
Current: 0 mA - 2 mA
Frequency: 0 kHz - 200 kHz
• LCD and rotary knob for operation and configuration • USB and RS-232C interface Electrical properties Output signal type Voltage Input type Charge (Piezoelectric, PE) Signal size Very small signals (1000000pC) Dynamical properties Maximum ...
Kistler
Voltage: 0 V - 5 V
Frequency: 10 kHz
This Thermocouple amplifier provides a high level of output, 0 to 5V for all temperature measurements. The K type is the most common but we can provide other types J, T, R..Highly compact, it allows the user to simplify ...
TEXYS
Frequency: 868, 902, 920 MHz
The Texense THNx2-WS4 wireless thermocouple conditioner has been designed and developed to simplify wiring harness instillations, helping to eliminate potential electrical problems and save on costs (replacement of slip rings). Its highly ...
TEXYS
The THNM-16x is an evolution of our thermocouple amplifier range. With an impressive sealing of IP67 and composite Autosport connector interface makes it the ideal choice for marine and harsh environment applications. ...
TEXYS
Power: 5 W
... offers quick and versatile set up. CV9-C: 9 channel charge amplifier with individually selectable gain (x1, x10, x100) per channel via a three way switch. CV9-CL: 9 channel charge amplifier with ...
The ADS-M Series manufactured by ASA-RT is a digital signal conditioning unit that is used to measure amplifier multichannel. This device is equipped with a field bus Profibus and a CANopen that provides ...
The playback equalizer labO2 allows realistic playback via high-quality subwoofers, loudspeakers as well as the excitation of shakers. With the equalizer function it is possible to play back recordings using the deployed filter with the ...
The playback equalizer labO2-V1 allows realistic playback via high-quality subwoofers and headphones as well as the excitation of shakers. With the equalizer function it is possible to play back recordings using the deployed filter with ...
... channel CCLD Signal Conditioning amplifier designed for measurements on satellites, gas turbines and large structures using a variety of acoustic and vibration transducers Type 2694 comprises general ...
Bruel and Kjaer
Voltage: 10 V
The model 6634C vibration amplifier is a microprocessor-based instrument designed to condition and display vibration data from rotating machinery. The instrument accepts inputs from a single-ended, differential PE or ...
Voltage: 0.3 V - 7 V
Current: 0 mA - 0.01 mA
Frequency: 1 kHz - 340 kHz
... available in space-saving (Q)SOP packages or as Chip-on-Board(COB) packages. Features 4-channel resistive transimpedance amplifier Programmable in 8 levels - 25 kΩ to 20 MΩ, 25 nA to 20 μA, 6 to 300 kHz Integrated compensation ...
Voltage: 0 V - 10 V
Current: 4 mA - 20 mA
... ticket printers. For a bulkhead cased version of the load cell amplifier and digitiser PCB see model LCA20 load cell amplifier display for weighing. PCB version of the load cell amplifier ...
Voltage: 5 mV - 90,000 mV
Current: 60 A - 100 A
Signal conditioning is required where the output of a transducer needs to be boosted or changed into a form suitable for the monitor or logging device which will be used. Our digital display units have a built-in monitor ...
Voltage: 27 V
Current: 2.4 mA
Straingauge Amplifiers Single and multi-channel Straingauge Amplifiers with precise, low-noise standard analogue outputs, display and setpoints for industrial applications. These accelerometers ...
Althen Sensors & Controls
Voltage: 220 V
Frequency: 50 Hz
The R-RF-10-RZ amplifier is a desktop amplifier explicitly designed for RZ code transmission in high-speed optical fiber communication systems. It amplifies tiny high-speed signal levels to a higher level ...
Voltage: 5 V
Frequency: 50 Hz
Single channel, handheld signal conditioner for GaAs-based fiber optic temperature sensors About the Pico M Fiber Optic Amplifiers Full featured, plug and play, 50 Hz sampling rate in a robust packaging. The Pico ...
Althen sensors
Voltage: 20 V - 30 V
Current: 20 mA
... Galvanically separation between input/output and auxiliary energy Brief Description The DC instrument amplifier HE 5020 serves for the signal conditioning of force sensors and loadcells with strain ...
... areas needing galvanic isolated amplifiers Measuring : distortion, pressure, force (gauge sensor) DESCRIPTION E300F4 amplifier conditioner can be used twofold: strain gauge sensor conditioner high precision ...
CELIANS
Voltage: 1.25 V - 5 V
SMA miniature strain gage conditioning amplifier is ideal for applications where signal conditioning is needed and space is limited. SMA is designed for the high accuracy strain measurement. ...
Advance Instrument Inc.
Voltage: 0 V - 10 V
Current: 4 mA - 20 mA
Applications The amplifiers of X-Sensors are suitable for the universal signal conditioning of strain gauges sensors. They are therefore suitable for amplifying the mV-sensor signal of any force and ...
X-Sensors AG
Voltage: 24 V
Current: 10 mA
Designed for strain gage sensors or potentiometers DIN rail fixture Front panel calibration shunt Compatible with the MCS trigger level modules The MCJ conditioner is fixed on a DIN rail in a polyamide casing. the I/O electrical connection ...
TME
Voltage: 0.5 mV - 10 mV
Current: 4 mA - 20 mA
Frequency: 1,000 Hz
FUTEK's IAA200 Analog Amplifier with Current Output is FUTEK’s brand new general purpose amplifier solution for in-line amplification of any full bridge strain gauge type sensor with mV/V range output. ...
FUTEK Advanced Sensor Technology, Inc.
Voltage: 5 V - 10 V
Current: 0 mA - 20 mA
Frequency: 1 Hz - 5,000 Hz
The XTSGA Load Cell Amplifier is a versatile signal conditioning unit for silo weighing, process control and PLC interface applications. It has been designed to be make calibration and configuration very ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining