- Electricity - Electronics >
- Switch and Relay >
- Contactless switch
Contactless switches
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 1,500 mA
Voltage: 1 kV
Diameter / length: 125 mm
Magnetic track sensor box 4 tracks, 2 optional for fine positioning optional fine positioning tracks with prewarning indication Maintenance-free signal storage and switching in case of power failure Wide angle ...
Primary current: 0 mA - 250 mA
Voltage: 0 V - 100 V
Diameter / length: 43.3 mm
Thermoplastic enclosure Non-contact safety switch Does not protrude into the door opening 119,5 mm x 140 mm x 43,3 mm Substitutes door-handle and safety switch, no further door ...
Primary current: 100 A
Voltage: 0.8 kV
Diameter / length: 35 mm
Thermoplastic enclosure Electronic contact-free, coded system Misaligned actuation possible 27 mm x 108.2 mm x 35 mm High repeat accuracy of the switching points Max. length of the sensor chain 200 m ...
Primary current: 3 A
Voltage: 30, 125, 250 V
Clippard MAS series switches (air to electric switches) use a standard miniature single pole double throw (SPDT) electrical switch which is UL, SEMKO, VDE and CSA certified. The range of switch ...
Primary current: 5, 3 A
Voltage: 125, 250, 30 V
... has sub-miniature air switches. These one of a kind switches use a standard sub-miniature single pole double throw electrical switch certified UL and CSA. These highly flexible and reliable switches ...
... magnetic safety switch for non-contact door monitoring RE2 magnetic safety switches are equipped with either complementary NC/NO contacts or equivalent N/O contacts which are addressed directly with ...
The SFN series safety non-contact door switches utilize magnetic type detection to monitor opening and closing of doors. The dedicated controller allows multiple connection of up to 30 units. The switches ...
The MN series magnetic non-contact switches utilize magnetic type detection to monitor opening and closing of actuator doors. The switches can be installed vertically or horizontally, and can also be ...
Primary current: 80 mA
Voltage: 24 V
Operating temperature: -20 °C - 55 °C
... Unicode Approach direction Can be adjusted in 90° steps Unicode evaluation Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Category ...
EUCHNER GmbH + Co. KG
Primary current: 0.25 A - 8 A
Voltage: 300 V
... monitoring The switch generates its own clock signal on the output lines OA/OB. Pay attention to this aspect when connecting to control systems and relays. Unicode evaluation Each actuator is highly coded (unicode). ...
EUCHNER GmbH + Co. KG
Primary current: 0.25 A - 8 A
Voltage: 24 V
... to 20 switches in series • Short circuit monitoring • 2 safety outputs (semiconductor outputs) • Category 4 / PL e according to EN ISO 13849-1 • Unicode Approach direction Can be adjusted in 90° steps Short ...
EUCHNER GmbH + Co. KG
Primary current: 2 A
Voltage: 24 V - 48 V
... control for doors / casings on hazardous machinery Manages person entry in hazard zones using an electrical locking key Contactless encoded electronic sensor with relay Category 3 total safety management without ...
COMITRONIC - BTI
Voltage: 24 V
MASSIMOTTO X5 - Safety Switch for single or double-wing doors Position control for doors / casings on hazardous machinery Contactless encoded electronic sensor with relay Category 3 total safety ...
COMITRONIC - BTI
Voltage: 12 V - 24 V
OPTO2S - Miniature safety Switch Position control for doors / casings on hazardous machinery Contactless encoded electronic sensor with relay Category 3 total safety management without an external ...
COMITRONIC - BTI
Primary current: 0 A - 0.5 A
Voltage: 0 V - 48 V
•High reliability and long service life thanks to contactless reed technology •Developed for harsh operating conditions, high protection class IP67 for electronics Robust and space-saving design •3 ...
ELOBAU
WM-547 Rotary Hand Controls are designed for a variety of off-highway applications. It is infinitely variable between 0° and 90° with applicable uses that include engine RPM, chassis module inputs and hydraulic pump control. The Rotary ...
Primary current: 10 mA
Voltage: 2 V - 24 V
Operating temperature: -40 °C - 85 °C
... robust and reliable, ideal for grip or panel mount applications. This 3-position switch provides operator comfort by reducing the movement required to change direction or switch gears. Backlighting provides ...
OTTO
Voltage: 10 V - 30 V
Series 1750 Solid State switches are available for use on most Tom Thumb and PHD products for simple interfacing to many types of electrical controllers. These switches are offered in 10-30 VDC current ...
Primary current: max 16.0 A
Voltage: max 250.0 V
... manufactured by Arcoletric, is a safety cut out switch that has a rated current of 16 ampere and a rated voltage of up to 250 V AC. It incorporates an NC contact, shatter switches and lever slope operations. ...
Primary current: 0.3 A
Voltage: 24 V
Operating temperature: -10 °C - 55 °C
... 7mm ON / 20mm OFF The MAGNASAFE MS5 are compact, non-contact safety switches designed for use with modern safety relays. Encapsulated into red ABS housings, the MS5 safety switches are easy to install ...
Mechan Controls
Primary current: 0.2 A
Voltage: 24 V - 250 V
Compact Housing Hygienic screw cap covers Wide 10mm sensing LED indication Up to PLe/Cat.4 with ZANDER safety relay High tolerance to misalignment 2 NC/1NO transistor circuits Protection category IP67
Zander GmbH & Co. KG, Hermann
Primary current: 1, 2 A
Voltage: 24, 230 V
Operating temperature: -25 °C - 80 °C
... designed to conform to IEC 60947-5-3 and be used as directed by ISO12100, ISO14121 and ISO EN14119. They feature magnet and reed technology, providing a high tolerance to misalignment and extreme temperatures. The mechanical ...
Idem Safety Switches
... size as the D40A allows standardization of machine design Safety category 3 (EN 954-1) Connect up to 30 non-contact door switches with LED indicators to one controller Two-color LED indicators
Voltage: 4 V
Window contact for status monitoring of windows and doors. Energy generation by solar power. Battery-free transfer of the opening state of doors and windows.
Voltage: 19.2 V - 30 V
Operating temperature: -20 °C - 70 °C
Contactless safety sensor for cascading Coding type: high Reset: locked Diagnostics: detailed ISD (in-series diagnostic) diagnostic system for a complete status image (not safety-relevant) ...
Primary current: 50 mA
Voltage: 9 V - 24 V
Diameter / length: 43 mm
CleanSwitch touchless switch Contact surfaces – and in particular, door handles – are responsible for spreading vast amounts of bacteria and viruses, some of which can pose a real risk to health. CleanSwitch provides ...
... unintentional opening Can be adjusted quickly through a larger switching displacement than mechanical switches and boundary detection by LED indication on the switch
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining