- Electricity - Electronics >
- Cable, Connector, Enclosure >
- Copper electrical cable
Copper electrical cables
Nominal voltage: 6 kV
Temperature: -55 °C - 80 °C
320 ‒ 480 MHz As Specified by Customer 820 ‒ 960 MHzAs Specified by Customer 1700 ‒ 1880 MHzAs Specified by Customer 1880 ‒ 2180 MHzAs Specified by Customer 2300 ‒ 2500 MHzAs Specified by Customer 2500 ‒ 2700 MHzAs Specified by ...
Yangtze Optical Fibre and Cable Joint Stock Limited Company
Nominal voltage: 500, 300 V
Temperature: 160, 5 °C
Cross-section: 0.75, 1, 0.5 mm²
... accordance with harmonised European design H05V-K, with ◁HAR▷testing mark for proven reliability and quality. • ◁HAR▷-style cables are widely accepted and can be used in Europe. • Different core insulation colours ...
Lapp France
Temperature: 90 °C - 260 °C
Length: 15 mm - 55 mm
Our automotive cables are the reliable and efficient connection for each wiring system. We offer an extensive range of products with various OEM and Tier 1 approvals. We supply both by international standards and the ...
LEONI
Nominal voltage: 600 V
Temperature: -40 °C - 90 °C
EcoFlex® PUR Continuous Flex Cable: Get the abrasion, UV, and oil resistance of a tough zero-halogen Polyurethane jacket in a flex cable that’s up to 40% smaller and 44% lighter than other 600V continuous ...
Alpha Wire
... conveyor technology, heating and climate technology In dry, damp and wet rooms As a monitoring, measurement and control cable for industrial applications For flexible applications without compulsory guide Properties PVC ...
LÜTZE
Temperature: -40 °C - 90 °C
SOLAR cable means flexible single cables specialty designed for wiring solar plants. SOLAR cables arc extremely robust and resist high mechanical load and abrasion. High temperature ...
Dielectric cables for blowing or pulling through ducts Entirely dielectric cable (earthing not required) Especially lightweight (a Tmax/weight factor much greater than 2), they can be deployed over ...
Acome
Nominal voltage: 220 kV
Temperature: 90 °C
Cross-section: 240 mm² - 2,500 mm²
... 5S ), the conductor temperature: not exceed 250 ℃ 4、0℃,≥18D (D) The minimum temperature of cable laying: 0℃ The minimum bending radius≥ 18D (D is the cable outer diameter )
Shanghai Morn Electric Equipment Company
Nominal voltage: 54 kV - 500 kV
Temperature: 90 °C
Cross-section: 240 mm² - 2,500 mm²
XDRCU–ALT Single–core Cable for 500/290 (550) kV with Copper wire screen and Aluminium laminated sheath Construction * Copper conductor, round stranded or ...
Brugg Kabel AG
Temperature: -30 °C - 70 °C
Cross-section: 25 mm²
High-voltage-resistant, insulated down conductor for maintaining the separation distance to electrically conductive parts according to IEC/EN 62305-3. Applicable up to an equivalent separation distance s ≤ 90 cm (in air) or s ≤ 180 cm ...
Nominal voltage: 1,800 V - 3,000 V
Temperature: -40 °C - 120 °C
Single conductor cable 120C, silicone insulation, 1800V, flexible, railway standard EN 50382-2 Applications : Shipbuilding, railways Electromechanics Approvals : SNCF / RATP (RAIL) Operating temperature : 120 °C ...
OMERIN
Nominal voltage: 22 kV - 50 kV
... insulated high voltage wire and cable offers excellent dielectric strength and flexibility. Operation over a wide temperature range and ease of silastic bonding are other outstanding characteristics of ...
Nominal voltage: 1,000 V
Temperature: -20 °C - 60 °C
Copper data Office cables Office data cables for future requirements The data transmission according to 1-10 Gigabit-Base-T is based on a full-duplex principle i.e. via all cable ...
Prysmian Group
Axon’ has designed tailor-made composite cables for 50 years. The company has integrated the manufacture of conductors (silver plated copper, tin plated copper, nickel plated copper,etc), ...
Axon Cable
Temperature: -25 °C - 75 °C
Length: 1,000 m
Telephone cables for interiors with LS0H sheath. SYT1-SH Indoor cables from 3 to 112 pairs, copper conductors with diameters of 0.5, 0.60 and 0.90 mm . Solid PE insulation twisted ...
CABLESCOM
Nominal voltage: 4 kV - 26 kV
Cross-section: 35 mm² - 400 mm²
Split Copper Shield Integrated Sheath Submarine Composite Cable Series
Dynamic Cable Orient cable's typically dynamic power cable design contains three power core phases for AC transition and single power core for AC. Each phase comprises a large copper ...
Nominal voltage: 33 kV
Temperature: 20, 30 °C
... temperature during cable short circuit: 250℃ for XLPE insulation (max. duration is 5 sec.) 4.Min. bending radius of cable during installation: (1)Single-core cable: 15D. (2)Multi-core ...
Nominal voltage: 300 V
Temperature: -10 °C - 80 °C
Cross-section: 0.2, 0.3, 0.5 mm²
... elastomer, an original technology developed by OKI Electric Cable, and by improving the internal structure, the company succeeded in developing a highly flexible, smaller diameter "ORP Cable" offered ...
Oki Electric Cable
Nominal voltage: 500, 300 V
Temperature: -40 °C - 120 °C
Cross-section: 0.14 mm² - 10 mm²
... 1000 Control cable is particularly suitable for use in cable track and moveable machine parts. The halogen-free and flame-retardant characteristics of the new jacket material reduce potential fire hazards. ...
SAB Bröckskes
... . in refineries or petrol stations) •copper conductor, stranded •lead sheath Errors and omissions excepted, weights and dimensions are approximate values. Tensile force only valid when cable sheath ...
Bayerische Kabelwerke
Nominal voltage: 450 V - 750 V
Temperature: -40 °C - 60 °C
Cross-section: 2.5 mm²
·2×HDMI 19PIN, male connector ·Chromium metal casing ·Gold plated connectors ·With nylon protection layer protect cable from abrasion ·Digital Transfers at rates up to 10.2Gbps+ ·High ...
Length: 305 m
UTP Cat.6 100% Cu LSZH CPR 305m, Orange, rigid, Pull Box Low Smoke, Zero Halogen Cable.
Electronic Grup, S.L
Nominal voltage: 800 V
Temperature: -30 °C - 70 °C
For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. Not approved for power and underground installation. DIN VDE 0815 ; directive 2014/35/EU RoHS 2011/65/EU EN ...
VOKA
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining