- Electricity - Electronics >
- Cable, Connector, Enclosure >
- Copper electrical cable
Copper electrical cables
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Nominal voltage: 600 V - 1,000 V
Temperature: -20 °C - 80 °C
Lapp Muller
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Highly flexible control cable with PVC core insulation and abrasion and oil resistant PUR sheath ÖLFLEX® CLASSIC FD 810 P - Power and control cable for versatile use in power chains in hash environmental ...
U.I. Lapp GmbH
Nominal voltage: 600, 1,000 V
Temperature: -50 °C - 90 °C
Cross-section: 16, 25 mm²
Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified ÖLFLEX® SERVO FD 796 CP - Screened servo cable for high dynamic power chain application in harsh conditions ...
U.I. Lapp GmbH
Nominal voltage: 1 kV
Temperature: -40 °C - 90 °C
Cold and oil-resistant cables for flexible applications under torsional load, halogen-free - 0.6/1 kV ÖLFLEX® TORSION FRNC: UL: cRUus AWM (II A/B) OIL RES I+II, power + control cable 0.6/1 kV, wind turbine ...
U.I. Lapp GmbH
Nominal voltage: 500, 300 V
Temperature: -50 °C - 90 °C
Cross-section: 0.75 mm² - 16 mm²
... D-VIERSEN · SABIX® A 260 PUR 12 x 1,5 mm² CE SABIX® A 260 PUR is a cold resistant, flexible control cable with numbered cores. This oil resistant cable is weather resistant and is recommended for use ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 2,000, 300, 500 V
Temperature: -50 °C - 90 °C
Cross-section: 0.5 mm² - 240 mm²
... control cable with numbered cores for continuous movement Marking for S 200 07741215: SAB BRÖCKSKES · D-VIERSEN · S 200 12 x 1,5 mm² CE High flex cable with numbered cores for continuous movement ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 1,200, 1,500, 350 V
Temperature: -50 °C - 90 °C
Cross-section: 0.34, 0.5, 0.75, 0.25, 0.14 mm²
... paired TPE/PUR data cable with coloured cores and overall copper screen Marking for SD 200 C TP 07890350: SAB BRÖCKSKES · D-VIERSEN · SD 200 C TP 3 x 2 x 0,5 mm² CE SD 200 C TP is a continuously ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 600 V - 1,800 V
Temperature: -5 °C - 70 °C
... All high voltage cables are produced with left-hand lay Specialities (available on request) • Composite cables with power + control + fibre optics • Cables with compounds for low ...
Temperature: -25 °C - 80 °C
Length: 500, 1, 100 m
UL-approved PUR-Data Transmission- /Control Cables in AWG 22, shielded, zero halogen, flame retardant, with small outer jacket. High flexible stranded copper conductor, closed twisted pairs. number ...
Metrofunk Kabel-Union
Temperature: -25 °C - 80 °C
Length: 500, 1, 100 m
UL-approved PUR-Data Transmission- /Control Cables in AWG 22, shielded, zero halogen, flame retardant, with small outer jacket. High flexible stranded copper conductor, closed twisted pairs. number of ...
Metrofunk Kabel-Union
Temperature: -10 °C - 80 °C
Cross-section: 0.08 mm²
Length: 1, 500, 100 m
Computer Cable with highly flexible stranded wire construction 0,08mm², outer shielding, 2 to 32 pairs, lightgray PVC-jacket. number of cores: 4, 6, 8, 12, 16, 24, 36, 48, 64
Metrofunk Kabel-Union
Nominal voltage: 600 V - 1,000 V
Single pole wire with flexible conductor in tin-plated copper class 5 First HEPR insulation type G21 special Second Halogen Free Type Elastometric blend insulation M21 For specific use with photovoltaic ...
Nominal voltage: 600 V
Temperature: -20 °C - 105 °C
• UL and CSA marked flexible unipolar insulated cable, for internal wiring or use in electronic devices not subject to mechanical stress and in fixed installation. • Flexible tinned electrolytic copper ...
PONY SRL
Nominal voltage: 300 V
Temperature: -25 °C - 80 °C
• Flexible cable suitable for internal wiring of electronic equipment and devices. • Extra-flexible red electrolytic copper conductor • Polypropylene insulation • Polyurethane sheath
PONY SRL
Nominal voltage: 300 V
Temperature: -20 °C - 80 °C
• Flexible cable suitable for internal wiring of electronic equipment and devices. • Flexible tinned electrolytic copper conductor • Semi-rigid PVC insulation ( SRPVC ) • PVC sheath 80°C
PONY SRL
Temperature: -50 °C - 200 °C
Length: 1,500, 1,000 mm
High Temperature Low Outgassing -This is a cable with insulation ceramic beads that can be used in a vacuum environment. -It is also ideal for thermocouple applications.
Cross-section: 0.32 mm²
Length: 5, 10, 2 m
SENTINEL- communication connector, which is specially used for Ethernet communication. The cable conforms to ISO/IEC 1180 (Cat.5) and TIA/EIA-568-C.2 (Cat.5e) standards. RJ45 and M12 D codes are available for connectors.
Nominal voltage: 300 V - 1,000 V
Temperature: -40 °C - 90 °C
Cross-section: 1.5 mm² - 240 mm²
IC AUTOMATION
Nominal voltage: 600, 1,000 V
Temperature: -40 °C - 80 °C
Cross-section: 0.38 mm² - 95 mm²
IC AUTOMATION
Nominal voltage: 300, 1,000 V
Temperature: -40 °C - 80 °C
Cross-section: 0.08 mm² - 240 mm²
IC AUTOMATION
Temperature: -20 °C - 70 °C
Length: 100 m
... mm : 6,6 • material : PVC PHYSICAL DATA : • Copper Content : kg/km : 19,1 • Cable Weight : kg/km : 44,1 • Min bending radius x 1/n : mm : 35/70 • Max.Tensile Strength : N : 150 ELECTRICAL ...
Cavel
Temperature: -40 °C - 80 °C
Length: 100, 500 m
... mm : 6,8 • material : PVC PHYSICAL DATA : • Copper Content : kg/km : 12,6 • Cable Weight : kg/km : 43,9 • Min bending radius x 1/n : mm : 35/70 • Max.Tensile Strength : N : 120 ELECTRICAL ...
Cavel
Temperature: -40 °C - 80 °C
Length: 500 m
... mm : 15,3 • material : PE PHYSICAL DATA : • Copper Content : kg/km : 83,1 • Cable Weight : kg/km : 188,4 • Min bending radius x 1/n : mm : 200 • Max.Tensile Strength : N : 800 ELECTRICAL ...
Cavel
Canare 75 ohm Super Low Loss Coaxial Cable ・Best suited to 3G-SDI/HD-SDI transmission. ・Highly-foamed PE insulation allows further improvement in the attenuation characteristics. ・Multi-layer insulation in which to ...
... equipment.) • As handy as conventional coaxial cables • Copper foil and high-density tinned copper braided shielding. • Highly-foamed multi-layer PE insulation
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm² - 50 mm²
power, control and connecting cable in electrical facilities for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in ...
CAE GROUPE
Nominal voltage: 300 V - 500 V
Temperature: -40 °C - 80 °C
power, control and connecting cable in electrical facilities for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in dry, ...
CAE GROUPE
Nominal voltage: 3,000 V
Temperature: -40 °C - 80 °C
power, control and connecting cable in electrical facilities for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in dry, ...
CAE GROUPE
Nominal voltage: 2, 3 kV
Temperature: -50 °C - 180 °C
Cross-section: 10 mm² - 300 mm²
... out of single insulated silicone extruded cables 1,8/3 kV with solderless crimped contact areas and additional insulation crimp Technical data Electrical conductor: • Round stranded copper ...
Druseidt
Nominal voltage: 3, 2 kV
Temperature: -50 °C - 180 °C
Cross-section: 70 mm² - 300 mm²
... out of single insulated silicone extruded cables 1,8/3 kV with solderless crimped contact areas and additional insulation crimp Technical data Electrical conductor: • Round stranded copper ...
Druseidt
Nominal voltage: 3, 2 kV
Temperature: -50 °C - 180 °C
Cross-section: 10 mm² - 300 mm²
... out of single insulated silicone extruded cables 1,8/3 kV with cable shoe-shaped contact areas and additional insulation crimp Technical data Electrical conductor: • Round stranded ...
Druseidt
Temperature: -200 °C - 260 °C
Cross-section: 0.22 mm²
Conductors are PVC insulated, twisted together and screened with a Mylar Aluminium tape with copper drain wire and an overall PVC jacket.
Temperature: -10 °C - 105 °C
The SS321 by Temperature Technology Ltd. is a mineral insulated and metal sheathed RTD cable. The unit is available with copper or nickel conductors. It is made out of stainless steel materials SS316 ...
Temperature: -90 °C - 200 °C
... resistance: 144Ω/100m nom. Capacitance: 100pF/m ±10% Weight: 1.6g/m Attenuation: 400MHz 130dB/100m RoHS Compliant – All Cables supplied by DJB Instruments UK Ltd and compliant with 2011/65/EU. The facts and ...
DJB Instruments UK Ltd
Nominal voltage: 400 V
Temperature: -65 °C - 200 °C
... Capacitance: 100 nom. 105nF/km max Impedance: 50±5Ω Weight: 3g/m Attenuation: 400MHz 130dB/100m RoHS Compliant – All Cables supplied by DJB Instruments UK Ltd and compliant with 2011/65/EU. The facts and figures ...
DJB Instruments UK Ltd
Nominal voltage: 500 V
Temperature: -90 °C - 260 °C
... Capacitance: 105nF/km max Weight: 8g/m Attenuation: 108dB/100m Bend Radius: Fixed 10mm, Flexing 20mm RoHS Compliant – All Cables supplied by DJB Instruments UK Ltd and compliant with 2011/65/EU. The facts and ...
DJB Instruments UK Ltd
Nominal voltage: 750, 500, 450, 300 V
Temperature: -12 °C - 80 °C
Cross-section: 0.75 mm² - 50 mm²
Carpel flat cable for moving equipment comes in a variety of N° conductors ranging from 6 to 24. The cores are identified according to CEI-UNEL 00722 tables and generally progressive numbering is used, with or without ...
Nominal voltage: 600 V
Temperature: -40 °C - 90 °C
EcoFlex® PUR Continuous Flex Cable: Get the abrasion, UV, and oil resistance of a tough zero-halogen Polyurethane jacket in a flex cable that’s up to 40% smaller and 44% lighter than other 600V continuous ...
Alpha Wire
Cross-section: 2.5 mm² - 120 mm²
Length: 0.2 m - 0.5 m
... H1Z2Z2-K cables; are suitable for UV rays, ozone, bad weather conditions and are made of cross-linked material that does not contain halogen gases. They are resistant to fire and do not transmit flame. Electrolyticly ...
Ege Kablo Endustri Malz. San. ve Tic. A.S.
... systems. H1Z2Z2-K Twin cables; are suitable for UV rays, ozone, bad weather conditions and is made of cross-linked material that does not contain halogen gas. They are resistant to fire and do not transmit flame. Optimized ...
Ege Kablo Endustri Malz. San. ve Tic. A.S.
Temperature: 70 °C
Cross-section: 0.75 mm² - 1 mm²
... Been Certified By VDE. Certificate Number: 40037175 Single core, thin stranded copper conductor cables.
Ege Kablo Endustri Malz. San. ve Tic. A.S.
Nominal voltage: 1,000 V
Temperature: -60 °C - 80 °C
The cable SKD02-T is a system cable for connecting digital camera systems and was particularly developed to be used in hazardous areas. It meets the requirements for cables and wires ...
Nominal voltage: 800 V
Temperature: -40 °C - 80 °C
Cross-section: 0.25, 0.75 mm²
The cable SKA02 is a system cable for connecting analog camera systems and was particularly developed to be used in hazardous areas. It meets the requirements for cables and wires according ...
Nominal voltage: 1,000 V
Temperature: -60 °C - 80 °C
... When using the applicable cable gland, it is possible to insert the cable directly into flameproof enclosures. The ASKDP03-T is a high speed cable for Industrial Ethernet for fixed installations ...
Nominal voltage: 2,000 V
Temperature: -40 °C - 80 °C
... The cable has excellent tensile and compressive properties Conductor: stranded tinned copper conductor Insulation: PE Color: white, yellow, blue, orange Inner sheath: PVC / LSZH Shielding: ...
Zhaolong Interconnect
The extruded flat cables LEONI exFC® consist of several, flat copper wires arranged in parallel and that are also insulated with materials. Special flat cables for lighting are with halogen ...
Nominal voltage: 500, 300 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm² - 185 mm²
... for selected torsion applications conditionally suitable for drag chains versatile use in many industries, particularly in machine and plant construction PVC control and connection cable in alignment ...
HELUKABEL
Length: 5, 3, 2, 1 m
... signal loss and screen ghosting. All cables have moulded hoods whereby the inner hoods are soldered 360° to the connector for end-to-end shielding. Conductors — 28 AWG stranded wire Contacts ...
Nominal voltage: 1 kV
Temperature: 20 °C
Cross-section: 10 mm² - 630 mm²
NAYBY cable is suitable for AC 50Hz power and distribution lines with rated voltage of 0.6/1kV, which can be used in fixed industrial power applications, underground tunnels, etc. Using steel wire ...
Henan Tong-Da Cable Company
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining