Temperature: 18 °C - 28 °C
Voltage: 115, 230 V
... Tester Calibrator helps calibration technicians comply with new regulatory standards up to four times faster than with traditional manual, multiple-product methods.The 5322A replaces the 5320A Electrical Tester Calibrator. The ...
Temperature: -20 °C - 70 °C
Pressure: -1 bar - 4,200 bar
... display Rechargeable battery or AC adapter ISO17025 accredited calibration with data (Included) HART Communication capability Measure mA or V, and with 24V loop power Easy-to-use, inexpensive pressure ...
Temperature: -20 °C - 70 °C
Voltage: -30 V - 30 V
... throughout the range. Each loop calibrator has a large, easy to read screen which simultaneously displays the measurement with the % of span. Accuracy to 0.01% of reading Measure, source, or simulate loop current Measure ...
Temperature: -20 °C - 50 °C
Pressure: 700 bar
Voltage: 25 V
The HPC50 handheld pressure calibrator is an intrinsically safe, dual pressure calibrator with options to add an additional two external pressure or temperature modules. The HPC50 pressure calibrator ...
Ametek Calibration
Temperature: -20 °C - 50 °C
Voltage: 0 V - 45 V
The mAcal Loop Calibrator is an economical and easy-to-use calibration device for sourcing and measuring mA signals. It is designed specifically for 2-wire transmitter loops with 4 to 20 mA signals. The keypad is ...
Ametek Calibration
Temperature: -20 °C - 50 °C
Pressure: 1,000 bar
Voltage: 24 V
... HPC40 Series handheld pressure calibrator is the world's first combined pressure and mA loop calibrator to be fully temperature compensated from -20 to 50°C. You can count on the same accuracy whether ...
Ametek Calibration
Temperature: -20 °C - 60 °C
Noise level: 50 dB
Voltage: 0 V - 24,000 V
... Large Color Display with color coded menus for simplified setup •Locate Loop Current Leakages Automatic indication of Loop Current and Leakage Current. Measure ground current ...
PIE - Pratical Instrument Electronics, Inc
The CL-420B is a handheld, programmable calibrator for measurement and signal output. It's great for measuring tiny currents and voltage signals, and it can power sensors while checking ...
Temperature: -200 °C - 2,310 °C
Voltage: 0 V - 600 V
• Source 4’’20mA loop current. • 4»2OmA (1KÇ load, 24V loop supply). • Source: 0’.’lOOmV, 0’4.000V, 0» 12.000V. • Measure: DC mA, mV, V, Q, Frequency (duty cycle), Diode, Continuity and temperature ...
TES Electrical Electronic Corp.
Temperature: -200 °C - 2,310 °C
Voltage: -3 V - 220 V
• Unique mapping function let you calibrate temperature (300 °C) or voltage (220V) directly. • iCal is a multifunction calibrator and an arbitrary function generator. • Source: mA (4 to 2OmA), V (0 to 15V, 0 to 7OmV), ...
TES Electrical Electronic Corp.
Temperature: -200 °C - 2,310 °C
Voltage: -3 V - 24 V
• Source 4»20 mA loop Current • Simulate electronic load (Max. 30V, 2OmA) • Test LED brightness (024mA) • Source 0’.’7OmV and O’15V • Calibrate temperature with selection of 11 types of thermocouples • Source frequency ...
TES Electrical Electronic Corp.
Voltage: 220 V
... function. Direct current or exchange current power supply make it convenient to use. Features ◆ Measure and source voltage, current (active or passive), mV and ...
Huaxin instrument (Beijing) Co., Ltd
Voltage: 28 V
Portable Handheld Loop Calibrator with an Accuracy of ±0.05% capable of measurement & simulation of mA & V signals.
Nagman Instruments & Electronics (P) Ltd.
Pressure: 80,000 Pa - 3,500,000 Pa
Voltage: 0 V - 50,000 V
The CA700 Pressure Calibrator is equipped with a silicon resonant sensor that uses Yokogawa proprietary DPharp technology. The CA700 has a basic accuracy of 0.01% of reading on pressure measurement and 0.015% of reading ...
Temperature: -20 °C - 49 °C
Pressure: 10,000 psi
Voltage: 0 V - 30 V
... damping, percent function, and switch test Built in Power supply to power device under test Applications: Process Market: Gas pipeline / transmission Refineries Chemical and Petrochemical Plants Power ...
Temperature: -10 °C - 55 °C
Voltage: 0 V - 30 V
... valve testing loop calibrator. The Fluke 773 mA clampmeter mA clampmeter can measure 4 to mA signals without breaking the loop and has a mA loop and V dc source built in. The Fluke 789 ProcessMeter features ...
Voltage: 0 V - 1,000 V
... - 1050 V (± 35 ppm) AC voltage: 1 mV - 1050 V, 15 Hz - 300 kHz (± 250 ppm) DC current: 0 - 20.5 A (± 150 ppm) AC current: 10 uA - 20.5 A, 15 Hz ...
Meatest spol. s r.o.
Voltage: 0 V - 1,050 V
... Specifications: DC voltage: 0 - 1050 V (± 10ppm) AC voltage: 1 mV - 1050 V, 15 Hz - 300 kHz (± 160ppm) DC current: 0 - 30 A (± 100ppm) AC current: ...
Meatest spol. s r.o.
Voltage: 0 V - 1,050 V
... calibration incredibly effective. Specifications: DC voltage: 0 - 1050 V (± 60ppm) AC voltage: 1 mV - 1050 V, 10 Hz - 100 kHz (± 500 ppm) DC current: 0 - 20.5 ...
Meatest spol. s r.o.
Voltage: 0 V - 2 V
Features: * Oyster case with flip-up display is ideal for handheld or benchtop applications * Large 3-1/2 digit LCD display and touch keypad * Display readings in mA or as a % of the 0 to 24mA range or as mV in voltage ranges ...
Voltage: 50 V - 300 V
The MI 2891 Power Simulator is a multi-purpose three phase power simulator for simulating typical situations in low voltage power supply systems. It is an excellent tool for training, ...
Voltage: 5 V - 10 V
... devices The TRANS CAL 7281 can be fitted with standard or rechargeable batteries for portable use or can run from an external power supply. Combined with a reference sensor the testing device provides a high-precision ...
burster präzisionsmesstechnik gmbh & co kg
Temperature: 5 °C - 45 °C
... with a maximum of 100 steps can be saved and started manually or via the interface. Features: - DC voltage up to ±100.0000 V, ±0.002 % - DC current up to ±50.0000 mA, ±0.005 % ...
burster präzisionsmesstechnik gmbh & co kg
Voltage: 300 mV - 60,000 mV
... the operation of the device easier for the user. For that reason the application possibilities are many: Calibration of current and DC-voltage meters Precise testing of thermocouple temperature measuring instruments Calibration ...
burster präzisionsmesstechnik gmbh & co kg
Temperature: 0 °C - 50 °C
Voltage: 9 V
... and regulate 4-20 mA from practically any process meter with or without a voltage generator. HI931002 can measure incoming current, provide power, and simulate 4-20 mA output to calibrate your process meter. The communication ...
Temperature: -10 °C - 50 °C
Pressure: 350 mbar - 1,000,000 mbar
Voltage: 200 mV - 30,000 mV
Druck's DPI610E Pressure calibrator The iconic Druck is back! The latest addition to the DPI600 Series is available now Built on a legacy of excellence When Druck launched the DPI610 series pressure calibrator ...
Temperature: -10 °C - 50 °C
Pressure: 25 mbar - 1,000,000 mbar
Voltage: 4 V
... multifunction calibration tools. Druck multifunction calibrators provide an all-in-one solution for your pressure measurement and generation needs. Our latest DPI 620 Genii multifunction process calibrator ...
Temperature: -20 °C - 50 °C
Voltage: 0 V - 24 V
... format. Equipped with a rechargeable lithium-polymer battery, MSC is able to power external devices or sensors and can be used without continuous power supply with the autonomy of up to 20 hours. With ...
Voltage: 0 V - 20 V
... Operation The 1044 voltage/current calibrator is housed in a pocket sized, ABS case and comes with a leather carry case containing a compartment for storing test leads. A single 9 V battery powers ...
Time Electronics
Voltage: 0 V - 1 V
... stable output. Power is provided by 6 AA batteries. Battery life is several months, depending on usage. The battery condition is monitored by an indicator situated on the top of the unit. The 1006 has up to 20 ...
Time Electronics
Voltage: 0 V - 1 V
The 1007 DC Millivolt Potentiometer and Calibrator is ideally designed to provide an excellent quality performance and functionality for very specific purposes. It is a precise, cost-effective type of ...
Time Electronics
... Process Calibrator LX229 is ahandheld,battery-operated instrument that measures and sources a variety of electrica lparameters. It can be widely applied in industrial fields and laboratories . The upper display allows ...
Temperature: 0 °C - 50 °C
Voltage: 0 V - 24 V
Process / Loop calibrator (current 0-24mA / voltage 0-24V) • Current source: 4-20mA, 0-20mA, 0-24mA • Voltage source: 4-20V, 0-20V, 0-24V • Basic accuracy: 0,025% • Ramp function ...
Voltage: 24, 30 V
Voltage: 0 V - 1,000 V
ULTRA PORTABLE CALIBRATOR • Full function, ultra portable calibrator • AC/DC Voltage output to 1000V • AC/DC current to 10A (500A using EA002 Coil) • Resistance to ...
TRANSMILLE
Voltage: 0 V - 1,000 V
PRECISION MULTIPRODUCT CALIBRATOR • 0 – 1000V DC / AC Voltage • 0 – 30A DC / AC Current • 0 – 1 GOhm Resistance ...
TRANSMILLE
Voltage: 0 V - 20 V
PRECISION MULTIPRODUCT CALIBRATOR • 0 – 1000V DC / AC Voltage • 0 – 30A DC / AC Current • 0 – 1 GOhm Resistance ...
TRANSMILLE
Temperature: -270 °C - 2,310 °C
Pressure: 0 bar - 1,000 bar
Voltage: 100 mV - 50,000 mV
CALYS 1000 is a field documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, ...
AOIP
Temperature: -250 °C - 2,310 °C
Pressure: 0 bar - 1,000 bar
Voltage: 100 mV - 50,000 mV
CALYS 1200 is a field documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, ...
AOIP
Temperature: -250 °C - 2,310 °C
Pressure: 0 bar - 1,000 bar
Voltage: 100 mV - 50,000 mV
CALYS 1500, most advanced and accurate laboratory electrical calibrator of the range, does not only work as a simulator (IN / OUT) but also as a dual channel thermometer (IN / IN) to perform comparison calibration. It ...
AOIP
Voltage: 250 V
... that generates/measures pressure signals, vacuum and simulates signals of thermocouples, resistance thermometers, voltage, current and other electrical signals. The Combitest modules are mostly used in labs designed ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining