- Electricity - Electronics >
- Switch and Relay >
- Current circuit breaker
Current circuit breakers
Primary current: 630 A
VAC: 12 kV
... high-voltage AC vacuum circuit breaker is an outdoor pole-mounted switch of vacuum arcing and SF6 insulation. It is featured by small, and excellent climatic protection performance, etc., ...
Primary current: 630 A
VAC: 7.2 kV - 12 kV
... three-phase AC 50Hz, rated voltage is 7.2 ~ 12kV of outdoor high voltage switch equipments.Circuit breaker in accord with the national standard GB1984 "high voltage AC ...
Zhuhai Powint Electric Co.,Ltd
Primary current: 20 A - 1,600 A
VAC: 0 V - 1,100 V
VDC: 900 V
TemBreak 2 is the Ultimate Safety Breaker. It has specifications which exceed international standards for safety. Direct opening action - recommended by IEC standards for machinery safety - is a feature of most models. A ...
VAC: 550 kV
... -550/Y4000-50 tank type SF6 circuit breaker is the 3-phase AC transmission equipment.Used in the power system of 550KV, can be realized the controlling, measurement and ...
Primary current: 0 A - 2,000 A
VAC: 0 kV - 36 kV
... life. Felix delivers trouble free operation with M2 class compliance. It also houses a draw-out type PT Compartment in the VCB trolley without compromising the compactness. Fixed type PT variant is also available as ...
CG Power Systems
Primary current: 800 A - 1,600 A
VAC: 415 V
TemBreak2 The Ultimate Safety Breaker - Catalogue of products for sale in Japan, Asia and Australia. These next-generation breakers emphasize safety with suitability for isolation and direct opening ...
Terasaki Electric Circuit Breaker
... accurately interrupt the over-current in case of a failure in the circuit after the secondary part of main transformer when the AC section is being operated. It is also a switch that ...
Primary current: 1 A - 63 A
VAC: 400, 230, 415 V
VDC: 10 V - 10 V
... Mainly used in AC 50/60Hz single-pole 230V or two three four-pole 400V circuit for overload and short circuit protection as well as for on-off switching electric equipment and lighting ...
Primary current: 5 mA - 300 mA
... amps and different residual current trip levels. DETAILED LOOK AT RCBOs The circuit uses a current transformer to measure AC current imbalance. The ...
Primary current: 0 A - 25 A
VDC: 6 V - 80 V
Single Smart Circuit Breaker A top technology patented high performance 3 transistors DC toggle/ fuse Full management of all electrical devices in the system Sanitization in energy ...
redler technologies
Primary current: 110 A - 400 A
VDC: 80 V
DD Frame - Higher Ratings Bridged Poles 80 Vdc Plug-in Terminals Description: Ratings: Available in 240 A & 250 A Number of Poles: Triple Pole Bridged: • 240 A to 250 A Curves: • AS (Long Delay) • BS (Medium Delay) • ...
CBI-electric: low voltage
Primary current: 15 A - 800 A
VAC: 230 V - 500 V
VDC: 125 V - 250 V
Regarding IEC standard for handle? ON/OFF indication, our products from 600A and above Frame Sizes have been marked base color as red for ON and green for OFF. After tripping, our handle position is in the middle and showes half red and ...
TECO ELECTRIC & MACHINERY Co., Ltd.
Primary current: 6 A - 800 A
VAC: 400, 690 V
... mainly used in the circuit of AC 50/60Hz, rated insulating voltage 690V (630 type is 500V), rated working voltage up to 690V, and rated current from 6A-800A in distribution line for distributing ...
Radin Electric Technology Co., lTD
Primary current: 1 A - 63 A
VAC: 250, 500, 750, 1,000 V
RNMD-63 DC MCB ( from1 to 63A, Curve B, C, up to 10kA ) used to protect the DC system line facilities and electrical equipment in buildings and similar places, and can also be used for infrequent on-and-off ...
Primary current: 10,000 A
VDC: 250, 500, 750, 1,000 V
Rating: 1 A - 63 A
DC Circuit Breaker - Miniature Circuit Breakers for DC and Solar Generation The JB is a DC circuit ...
Primary current: 160 A - 250 A
Moulded Case Circuit Breakers New TemBreak2 Catalogue No. ’12-I64E 160A and 250A frames of new compact breakers can provide saving space and saving money to you.
Primary current: 4,000, 2,500 A
VDC: 1,000 V
... contrast to standard contact circuit breaker, which requires additional work space for plasma ejection in its operation, AFB® circuit breaker applies principle of power ...
Primary current: 4,000 A
VAC: 12 kV
... rated current is up to 4000A. The circuit breaker conforms to GB 1984-2014 "High Voltage AC Circuit Breaker", JB/T 3855-2008 "3.6~40.5kV ...
Zhuhai Comking Electric Co.,Ltd.
Primary current: 0.5 A - 125 A
VAC: 230 V - 500 V
VDC: 12 V - 230 V
... event of failures due to overloads, short circuits and for the life-saving differential versions even in the case of dispersed currents. The offer includes: • Thermal magnetic ...
Primary current: 0.1 A - 100 A
VAC: 400, 250, 600, 125 V
VDC: 125 V
... Mil-std-202 method 204 Umidita: IEC 68-2-3 Mil-std 202 method 103/A Note Single or multipole circuit breaker, mid to large current range in a compact E-frame case,large ...
COMESTERO SISTEMI
VAC: 230, 400 V
Rating: 6 A - 63 A
... Earth-leakage circuit breaker (ELCB) is suitable for AC 50/60Hz, rated voltage 230/400V, rated current 1-63A lines, with leakage, shock, overload, short circuit ...
Zhejiang Geya Electrical Co., Ltd
Primary current: 1 A - 63 A
VAC: 250, 500, 750, 1,000 V
VDC: 0 V - 1,200 V
Anson NKC1-63DC Series PV DC Isolator Switches are mainly be used in PV solar power system, which are applied for DC solar combiner box, controller etc. The Max voltage up to 1200VDC, ...
SHANGHAI ANSON ELECTRIC TECHNOLOGY CO.,LTD
Primary current: 2,300 A
VAC: 1,800, 3,600 V
VDC: 4,800 V
The UR26-64 is a trip-free DC high-speed current limiting air circuit-breaker, single pole unit, bi-directional, with electromagnetic blowout, direct ...
Secheron
Primary current: 630 A - 4,000 A
VAC: 12 kV
VAC83 VCB is in a new type indoor switch device, which is mainly used in three-phase AC power system with rated voltage of 12kV, and rated frequency of 50-60Hz. It has the advantages ...
Wenzhou Vacem Technology Co., Ltd
Primary current: 0 A - 1,600 A
VAC: 550, 800 V
... of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 2(distribution circuit breaker) ...
Andeli Group Company
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining