... -stage phase overcurrent protection (50/51P, 67P) • Zero sequence overcurrent protection (50/51G, 67G) • Sensitive earth fault protection (51SEF, 67SEF) • ...
NR Electric
Tripping current: 5 A
Trigger voltage: 110 V
... VIPAM3500C is a digital integrated protection relay that enables high-precision measurement and protection relay for switchgear power equipment. The ...
VitzroEM Co., Ltd.
Trigger voltage: 100 V - 460 V
... MOTOR PROTECTIVE GUARD All-in-one unit combining Reverse Power, Overload, Over Current and Short Circuit functions "Predictor" early action feature One common alarm output eases installation "Pathfinder" ...
Meagacon AS
The relay type NA21 is typically used in HV, MV and LV radial networks as feeder or power transformer protection. In solidly grounded systems the residual overcurrent ...
THYTRONIC
... demand load shedding, power factor* Power quality analysis* Digital Measurement True RMS Phase Currents True RMS Line Voltage Active Power (kW) Reactive Power (kvar) Apparent ...
Orion Italia
Feeder protection relay The ARKENS PR Feeder range of relays is designed for Medium Voltage network applications including all phase and earth overcurrent protection ...
SCLE SFE
The DKR-24 Series, manufactured by Entes, is an overcurrent protection relay designed to avoid damage from overloading the motor. This is equipped with electronic coil controller, same ...
... enhanced security during external faults with heavy CT saturation • Protection functions include IEEE devices 87B, 27, 59, 60, 81, 50LS, 50BF, 50/51/67, 50N/51N/67, 46/50/51/67 • Backup overcurrent ...
ERLPhase
Tripping current: 5 A
Trigger voltage: 250 V
... differential protection and short-circuit protection relay for generator protection against internal short circuits (leaking currents). The MDR-2 ...
DEIF
Modular protection relays | Timers and protection relays Technical Data Compact Size – 1 Module ( 17,5mm) Usable for current ...
... ~1000Vdc) and the chassis (earth) of the power battery pack (pure electric or hybrid) power supply system. The measurement technology used in this product can monitor the insulation faults on the DC ...
Chongqing Blue Jay Technology Co. Ltd
Tripping current: 30 mA - 30,000 mA
... series self-toroid or external toroid (Toroidal Residual Current Transformers, Collector and Multiplexer Toroidal Current Transformers). Our Aktif RCR and ELR series residual current ...
Tripping current: 15 A
Trigger voltage: 250 V
... unique sensitivity to currentsbelow one amp (1 A) allows more flexible motor design solutions, as well as placement of the protector outside ofthe motor windings, in more accessible and serviceable locations.Available ...
Differential relays with separate toroids for flus-mounting or Din35 rail installation The DELTA range of modular and built-in residual current relays, in combination with the Del and ...
... circuit in case of either leakage current fault or arc fault. APPLICATION: AFDD3-40, applicable to AC circuits with rated current up to 40A, provides protection against ...
The AC / DC Earth Leakage Unit is a residual current detection unit which is powered from the vehicle’s battery or AC supply and measures the sum of the current ...
... Logic. Rich protection functions Feeder protection; Transformer protection; Motor protection; Capacitor protection; Voltage protection; ...
... one-box solutions for protection and control, which allow protection of primary equipment by simultaneously accomplishing control and monitoring functions in electric power systems. The overcurrent-time ...
Sprecher Automation
Tripping current: 0 A - 40 A
... Specifications - Power supply voltage: 230 / 400 VAC - Consumption: 2W - Pilots: pump running, alarm, low level, maximum current, minimum current, reset time - Protections: ...
Overcurrent protection for various items of power system plant as frame earth leakage protection of metal clad switchgear & tank earth fault protection The ...
Mors Smitt BV
-Digital relay for Epoxy Fault Interrupter(EFI) -51, 50, Sectionalizer Function, Overcurrent Lock Function and Contact Wear Monitor -Programmable SCADA I/O port -Inrush current suppression
ENTEC ELECTRIC & ELECTRONIC CO.,LTD
... and Motor Protection Relay Key Features: Multifunctional yet user-friendly Extensive thermal protection functions optimal for low and medium-sized asynchronous motors Directional earth ...
Vamp
AQ 110 is a sophisticated micro-processor based arc flash protection unit with combined current and arc sensing. Combined current and arc sensing provides an integrated dual trip criteria. ...
Arcteq Relays Ltd
Tripping current: 100 mA - 100,000 mA
The ALP series covers overcurrent protection for either instantaneous or timed overcurrent including definite time overcurrent. Offers standard IEC and IEEE inverse time overcurrent ...
... the control or signal power) smart cutout, can accurately detect the fault current and trigger the tripping circuit breaker within 0.02 seconds (from the occurrence of overcurrent to the activation of ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining