Primary current: 0.2 A - 25 A
VAC: 480, 250 V
VDC: 65 V
... Bulletin 1492-GH and 1492-GS High-density Miniature Circuit Breakers are thermal-magnetic type supplementary overcurrent protective devices. Our single-pole, high-density miniature circuit ...
Primary current: 0.5 A - 63 A
VAC: 250, 440 V
VDC: 440, 220 V
Our Bulletin 1492-D DC High Voltage Miniature Circuit Breakers provide overcurrent and short circuit protection for higher voltage DC circuits. ...
The PKZ-SOL string circuit breaker from Eaton’s Moeller series provides a fuseless alternative for protection against short-circuit currents. To ensure maximum protection, each PKZ-SOL ...
The APG/UPG magnetic circuit protector provides low-cost power switching, reliable circuit protection and accurate circuit control in one complete package. It is intended for use in data ...
Primary current: 1 A - 40 A
VAC: 250 V
VDC: 80 V
BSB B1 Series Hydraulic-magnetic Circuit Breakers are compact and durable, ideal for applications with limited space. They offer various handles and can be used in telecommunications, lighting, railway ...
ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD
Primary current: 1 A - 63 A
VAC: 415, 250, 127 V
VDC: 65, 80 V
... series hydraulic-magnetic circuit breaker is a front-mounted circuit breaker. It has up to four poles and can be used for both AC and DC applications. ...
ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD
Primary current: 1 A - 200 A
VAC: 415, 250, 240 V
VDC: 125, 80 V
The BSB B3E series hydraulic-magnetic circuit breaker is a compact yet powerful circuit breaker. Its hydraulic magnetic technology is unaffected by environmental temperatures, ...
ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD
Primary current: 75,000 A
VDC: 15,000 V
... family of VCP-WG circuit breakers that meet and exceed the service duty requirements of generator circuit application defined by IEEE. Breakers are designed to meet the ...
Primary current: 63 A - 800 A
VDC: 600 V - 1,000 V
MCCBs for DC use are available from 63A (600VDC) up to 800A (1000DVC). MCCBs for DC use are mainly used at the DC side of photovoltaic generation systems, or in DC ...
Primary current: 1 A - 10 A
VDC: 24 V
The BLOCK electronic circuit breakers are designed for a variety of requirements in machines and devices. Available are three different tripping options. Circuit breakers ...
Primary current: 1 A - 20 A
VDC: 24 V
... comprehensive DC 24 V protection and distribution options for machines and process control. It helps optimise the functionality and number of components. The REX22D-T electronic circuit protector selectively ...
E-T-A
Primary current: 6 A
VDC: 230 V
... profile which adds to the streamlined and co-ordinated look of the installation. These new products feature a rated short-circuit capacity of 10,000 A, a rated voltage of 230/400 VAC and tripping characteristics of ...
Primary current: 1 A - 125 A
VDC: 205 V - 600 V
... is a compact breaker capable of handling high amperage and high DC voltage applications. UL Recognized with up to a 440VDC rating, makes the CX-Series ideal for 380VDC datacom applications. With an ...
Primary current: 160 A - 2,000 A
VDC: 1,000 V
Available up to 1000V DC. Terasaki DC breakers are suitable for photovoltaic power generation and UPS system with large battery capacities.
... has both roles of the breaker and the switch. This device is exclusively for the alternating current and interruption should not be carried out at the direct current section. This breaker ...
Primary current: 1 A - 63 A
VAC: 400, 230, 415 V
VDC: 10 V - 10 V
DZ47 AC MCB circuit breaker series is used in lighting distribution system or motor distribution system for protecting overload and short-circuit condition. The product is light in weightreliable ...
Primary current: 1 A - 63 A
VAC: 250, 500, 750, 1,000 V
RNMD-63 DC MCB ( from1 to 63A, Curve B, C, up to 10kA ) used to protect the DC system line facilities and electrical equipment in buildings and similar places, and can also be used for infrequent on-and-off ...
Primary current: 10,000 A
VDC: 250, 500, 750, 1,000 V
Rating: 1 A - 63 A
DC Circuit Breaker - Miniature Circuit Breakers for DC and Solar Generation The JB is a DC circuit ...
Primary current: 4,000, 2,500 A
VDC: 1,000 V
... contrast to standard contact circuit breaker, which requires additional work space for plasma ejection in its operation, AFB® circuit breaker applies principle of power ...
VDC: 600 V - 800 V
Thermal magnetic circuit breakers 600-800 Vdc circuit breakers for photovoltaic systems. Can be fitted with Btdin contacts and shunt trips
VDC: 48 V - 600 V
Rating: 1 A - 63 A
GYM9H-Z DC circuit breaker is used for DC voltage up to 600V, rated current up to 63A for overload and short circuit protection, and ...
Primary current: 1 A - 63 A
VAC: 250, 500, 750, 1,000 V
VDC: 0 V - 1,200 V
Anson NKC1-63DC Series PV DC Isolator Switches are mainly be used in PV solar power system, which are applied for DC solar combiner box, controller etc. The Max voltage ...
SHANGHAI ANSON ELECTRIC TECHNOLOGY CO.,LTD
Primary current: 2,300 A
VAC: 1,800, 3,600 V
VDC: 4,800 V
The UR26-64 is a trip-free DC high-speed current limiting air circuit-breaker, single pole unit, bi-directional, with electromagnetic blowout, direct instantaneous over-current release, ...
Secheron
Primary current: 10, 63 A
VDC: 1,000 V
The circuit breaker has the functions of short circuit protection, overload protection, control, isolation and so on. It is suitable for terminal power distribution, civil construction, ...
Aswich Electrical Co., Ltd
Primary current: 3 A - 63 A
VDC: 1,000 V
I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo. SPECIFICATIONS I am text block. Click edit button ...
Zhejiang Benyi Electrical Co.,ltd.
Primary current: 0 A - 25 A
VDC: 6 V - 80 V
Single Smart Circuit Breaker A top technology patented high performance 3 transistors DC toggle/ fuse Full management of all electrical devices in the system Sanitization in energy ...
redler technologies
Primary current: 3,000, 4,000, 6,000 A
VDC: 750 V - 1,800 V
Entec's DC High-Speed Circuit Breaker (HSCB) symbolizes our advanced technology in DC interrupting. Entec's HSCB(EDB-09 and EDB-18) is used to manage DC ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining