- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- DC flow meter
DC flow meters
Process pressure: 0.6 mbar - 4 mbar
Precision: 0.2 %
... Robust housing Excellent flow mesurement accuracy, can measure duplex flow, electromagnetic debimeter with 4-20mA and other outputs General Features Excellent small flow mesurement ...
Process temperature: -15 °C - 85 °C
Integral Ultrasonic Flow meter for liquid measurement The S-flow flow meter contributes to energy savings and production process solutions. Reduces ...
Precision: 0.25, 0.4 %
Repeatibility: 0.5 %
... various sensor parameters, anticipating possible problems. The battery converter with integrated modem MV255, flow meters, energy meters, contact our specialists.
ISOIL Industria Spa
Process temperature: -30 °C - 130 °C
Precision: 1, 3, 0.5 %
Repeatibility: 0.15 %
... the Modbus. Description The portable clamp-on flow meter IFX-P210, flow meters, energy meters, ultrasonic flowmeters, and industrial automation systems ...
ISOIL Industria Spa
Process pressure: 16 bar
Precision: 2 %
The insertion flowmeter CS3795 ISOMAG in compact version without indicator, which integrates sensor and converter in the same body. The compact insertion flow meter without indicator ...
ISOIL Industria Spa
Process temperature: -30 °C - 160 °C
Precision: 1 %
Repeatibility: 0.2 %
... calculate the instantaneous flow rate value. The digital technology DSP (Digital Signal Processing) guarantees a low sensitivity of the system towards potential disturbing factors. The AI.M-SONIC module can also function ...
ASIT ITALIA
Process temperature: -30 °C - 160 °C
Process pressure: 2.5 MPa
Precision: 1 %
The AI.FFSONIC.INLINE flow measurement system is composed of a digital converter and two ultrasonic transducers with in-line insertion on the pipes. The transit time of a fluid, inside a cylindrical section tube, is the ...
ASIT ITALIA
The AI.C-Sonic transit time flowmeter is the ideal solution for flow measurement with transit time technology, for small pipes. The instrument, compact and very small (about 115x60mm), is suitable for ...
ASIT ITALIA
Process pressure: 1.6, 2.5, 4 MPa
Precision: 5 %
Electromagnetic flowmeter type PEM-500 is applicable to the measurement of flow of the liquids with minimum conductivity of 5ěS/cm. Device measures flow and volume of liquids in both directions ...
Volumetric flow rate: 0.3 m³/h - 71 m³/h
Process temperature: -15 °C - 100 °C
Process pressure: 0 bar - 10 bar
... Treatment. 2.FineTek EPD/EPR series Flow Meter with high quality 3.EPR series Paddle Wheel Flow Meter 4.FineTek EPR Paddle Wheel Flowmeter 5.Total ...
Mass flow rate: 1 kg/h - 20,000 kg/h
Process temperature: -20 °C - 450 °C
Process pressure: 0 bar - 6 bar
Microwave-based flow measurement for bulk solids MF 3000 Numerous bulk material applications require continuous measurement of mass flow, e.g. for exact dosing of a material or to ...
Process temperature: -30 °C - 80 °C
Precision: 2, 1 %
... solution for monitoring the flow or velocity of open channels, agricultural irrigation or groundwater. the best solution. Application : ● Open channel flow rate or flow monitoring ...
Holykell
Process temperature: -30 °C - 80 °C
... Ecological discharge flow ● Monitoring of flow rate of agricultural water channels ● Sewage discharge control Advantages 01 24GHz frequency modulated continuous wave (FMCW), and output measurement ...
Holykell
Volumetric flow rate: 0.1 m³/h - 381,703.5 m³/h
Process temperature: -10 °C - 60 °C
Process pressure: 0 bar - 250 bar
Electromagnetic Flow meter does not have any moving parts, ideal for wastewater applications or any dirty liquids which is conductive or water based, or for applications where low-pressure drop and low ...
Holykell
Volumetric flow rate: 0.1 m³/h - 9.5 m³/h
Process temperature: -20 °C - 130 °C
Process pressure: 0 bar - 64 bar
The RIF100 is an electromagnetic flow meter that utilizes Faraday's principle to measure the velocity of the liquid and convert it into a signal proportional to the flow. Among its ...
Riels Instruments
Process temperature: -30 °C - 160 °C
Precision: 1 %
Repeatibility: 0.2 %
... environments with vibrations and disturbances. The flow meter is able to operate in a wide range of temperatures and pressures, making it versatile. The RIF600S has an LCD display that displays flow ...
Riels Instruments
Volumetric flow rate: 1.6 m³/h - 1,600 m³/h
Process temperature: -10 °C - 60 °C
Process pressure: 20, 16 bar
... are expected in the gas flow, it is necessary to install a filter upstream of the meter to ensure the long-term durability of the device. The meters can be installed both horizontally ...
Riels Instruments
Volumetric flow rate: 0.4 l/min - 1,000 l/min
Process temperature: -40 °C - 150 °C
Process pressure: 0 bar - 16 bar
Positive displacement meter for oil high accuracy for high viscosities easy cleaning Operation: The positive displacement meter COVOL works with an oscillating piston principle. During one rotation ...
Volumetric flow rate: 0 l/min - 13,333.3333 l/min
Process temperature: -40 °C - 120 °C
Process pressure: 16 bar - 63 bar
... puises changing with time, instantaneous flow and by the total amount of puises total flow is measured. With the number of these puises changing with time, instantaneous flow and by the ...
ENELSAN ENDUSTRIYEL ELEKTRONIK SANAYII A.S.
Process temperature: -20 °C - 120 °C
Process pressure: 16 bar
Immersion type turbine gas flow meters are precision flow meters used to measure the amount of air flow in large pipes. It is a device that does not ...
ENELSAN ENDUSTRIYEL ELEKTRONIK SANAYII A.S.
Process temperature: -30 °C - 160 °C
Precision: 1 %
... Ultrasonic flowmeter is improved for long-term online measurement with wide measuring range. It is produced as converter protection class IP67 and sensor protection class IP68. It is suitable for use in many liquid measurements. Ultrasonic ...
ENELSAN ENDUSTRIYEL ELEKTRONIK SANAYII A.S.
Volumetric flow rate: 0 l/min - 50 l/min
Mesa Lab 's newest standardized primary volume flow meter offers easy-to-use calibrations with unmatched flow ranges, accuracy and portability. The FlexCal offers you: USB connectivity Flow ...
CleanAir Europe
Volumetric flow rate: 0 l/min - 30 l/min
Precision: 1 %
... piston flowmeters with Bios DryCal® technology in the DC-Lite and DC-2 digital flowmeters. They allow calibration of air sampling pumps, rotometers or other flow instruments. ...
CleanAir Europe
Volumetric flow rate: 0 l/min - 30 l/min
Precision: 1 %
... Bios DryCal® technology in the DC-Lite and DC-2 digital flow meters is available in the Defender 510The Defender 510, 520 and 530+ calibrators make it easier than ever ...
CleanAir Europe
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 10 bar
Precision: 2 %
... VPFlowScope M can be installed under pressure and measures (bi-directional) flow, pressure, temperature, and total flow simultaneously. The flow meter is an all-in-one ...
VPInstruments
Volumetric flow rate: 0 m³/h - 1,000 m³/h
Process temperature: 0 °C - 60 °C
Process pressure: 0 Pa - 3,500,000 Pa
... consumption of machines, cost allocation, and pressure loss monitoring. It measures (bi-directional) mass flow, temperature, pressure, and total flow which is key data for point of use compressed air ...
VPInstruments
Volumetric flow rate: 2.2 l/min - 50 l/min
Process temperature: 20 °C - 32 °C
Process pressure: 0 bar - 10 bar
... Thermabridge™ technology, the VPFlowScope In-line can perform accurate flow measurements. The built-in display will show the actual and total flow, and the Modbus and analog 4 .. 20 mA outputs enable ...
VPInstruments
Volumetric flow rate: 0.2 m³/h - 400,000 m³/h
Process temperature: -40 °C - 160 °C
Precision: 1 %
The SGM-101F flowmeters operate on the ultrasonic pulses transit time difference principle. The great advantage is the mechanical installation, because it is not necessary to cut the pipe. The sensors are simply clamped ...
Volumetric flow rate: 90 m³/h - 1,195 m³/h
Process temperature: -20 °C - 60 °C
Process pressure: 0 bar - 16 bar
... consumption of individual machines and analyze your leakage flows with just one measuring device. Advantages of the VA 525 flow sensor: - Measurement of mass flow rate, output of ...
Volumetric flow rate: 909 m³/h - 1,195 m³/h
Process temperature: -30 °C - 80 °C
Process pressure: 0 bar - 40 bar
Flow meters for compressed air as well as various technical gases Reduce your energy costs and increase your sustainability with the VA 521. Monitor the consumption of each machine and analyze your ...
Volumetric flow rate: 0.2 m³/h - 95,560 m³/h
Process pressure: 1.6, 1, 0.6 MPa
... SMT) are implemented to improve the reliability. Electromagnetic flow meter technical parameters Display: reaches 8element liquid crystal display, current clock to indicate flow ...
Features : Designed for industrial application. Air flow measurement up to 120 m/s. Resistant to high temperature, high pressure, dust, and corrosion. Sensor type : Pt20 / Pt300(Air velocity) / Pt1000(Temp.) Measuring ...
Features : Suitable for clean air. Resistant to high pressure and high temperature. Sensor type : Thermal mass flow sensor Measuring range : 0 ... 90 m/s Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / ...
Sensor type : Thermal mass flow sensor Measuring range : 0.1 ... 848 m³/h Output : 4 ... 20 mA / 0 ... 10 V / RS-485 / Frequency / Pulse Accuracy : ±1.5% F.S. IP rating : IP65 (IP67 option)
Process temperature: -20 °C - 60 °C
The mag-flux M1 measuring transducer was developed specifically for use with the magnetic-inductive mag-flux-series flow sensors. With an optionally available operating module and a local display, the measuring transducer ...
Volumetric flow rate: 0.2 m³/h - 75 m³/h
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 16 bar
Mounting position: Arbitrary Mounting type: Line fitting Supply voltage: 18 – 30 V DC Accuracy: ISO 8573-1: class 141: ± (3 % MW + 0,3 % MEW) / ISO 8573-1: class 344: ± (6 % MW + 0,6 % MEW) Max. ...
Process temperature: 15 °C - 60 °C
Process pressure: 2.4 bar - 3.5 bar
D700T is the best performance pressure-insensitive mass flow module designed for critical semiconductor manufacturing process. D700T adapted the HORIBA CRITERION pressure-based flow measure and control ...
HORIBA STEC
Volumetric flow rate: 6.3 l/min - 30 l/min
Process temperature: 0 °C - 60 °C
Process pressure: 0.2 bar - 10 bar
... air entry causing inaccurate measurements, the flow meter is sited upstream from the solenoid valve. The flow meter's output are pulses, where the frequency or the ...
Process temperature: 40 °C - 230 °C
Precision: 1 %
Repeatibility: 0.25 %
SITRANS FS290 is a portable ultrasonic flowmeter system for monitoring volumetric flow in pipes. It contains the SITRANS FST090 battery-operated transmitter and SITRANS FSS220 clamp-on sensors. Install ...
Volumetric flow rate: 0.2 m³/h - 212 m³/h
Process temperature: -20 °C - 60 °C
Process pressure: 0 bar - 16 bar
... of the EE741 flow meter is optimised for easy installation and maintenance. Once the gauge mounting block is installed in the pipeline, the transmitter can be installed and removed without any pipework. ...
E+E ELEKTRONIK
Process temperature: -20 °C - 80 °C
Process pressure: 1.6 MPa
Precision: 1.5 %
... -LDG insertion electromagnetic flowmeter is a type of flow meter that is designed to measure the flow of conductive liquids in large pipes. This type of flow ...
Supmea Automation
Process temperature: -328 °F - 1,166 °F
Precision: 1, 3 %
Repeatibility: 0.15 %
... the gaseous medium providing superior flow averaging of up to 4 planes of the pipe section. With this configuration, the G736 flow meter averages out crossflow profile effects and achieves ...
FLEXIM Flexible Industriemesstechnik GmbH
Process temperature: -40 °C - 350 °C
Process pressure: 1.6, 2.5, 4, 6.3 MPa
Precision: 1 %
ZHYQ’s PT124B-503 vortex flowmeter is a kind of advanced speed flowmeter and has a wide range of applications. Flow metering, measurement and control of liquids, vapors and most gases. Features With ...
Shanghai Zhaohui Pressure Apparatus Co.,Ltd.(ZHYQ)
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining