- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Differential pressure transmitter
Differential pressure transmitters
Pressure range: 30,000 Pa - 110,000 Pa
Long-term stability: 0.05 % - 1.25 %
Process temperature: -5 °C - 65 °C
The new differential pressure Rotronic transmitters PF4 and PF5 with two different sensor technologies (thermal measuring method in PF4 and diaphragm sensor in PF5) consistently produce perfect measurement ...
Pressure range: 50, 100, 250, 500 Pa
Process temperature: -100 °C - 200 °C
... glass front plate and a removable humidity sensor. • Measures differential pressure, humidity and temperature • Designed specifically for clean rooms • Removable humidity and temperature probes ...
Pressure range: 0 Pa - 2,500,000 Pa
Precision: 0.25, 0.5 %
Process temperature: -40 °C - 85 °C
DPW Differential Pressure Transmitter •Wide range power supply •Measure by diffusion silicon sensor , advanced membrane isolation •Connection reverse protect ,OVP、OCP •Design for anti-interfere, ...
Pressure range: -20 Pa - 80 Pa
Differential pressure transmitter -20 Pa..+80 Pa, 4..20mA output Type DE23 without display Pressure connection: Aluminum screw connection for 8/6 mm hose 24 V DC, M12 plug connection, ...
Pressure range: 0 MPa - 2 MPa
Process temperature: -20 °C - 80 °C
Differential Pressure Transmitter HTW-CQ04531 series diffused silicon differential transmitters are consist of both isolation membrane differential ...
Pressure range: -500 Pa - 500 Pa
... . *If you have any query, please contact us by Direct Industry or by email contact@aecl.com.tw Aecl ADP Differential Pressure Transmitter [Features] ● Media compatibility: air, N2, O2 ● Measurement ...
Pressure range: -1 bar - 600 bar
Process temperature: -30 °C - 200 °C
Measurement range: -1…0 bar/ 0…600 bar, permissible overload is four times the nominal span. For absolute, relative and differential pressure. Sensors with electronics and housing connection with ...
Process temperature: -20 °C - 85 °C
... Connect the “red and white” differential pressure signal on the terminal to the pulse computer controller. 2. Connect the high and low pressure of the medium to the inlet and outlet ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining