- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- DN100 - 4" flow meter
DN100 - 4" flow meters
Process pressure: 1.6, 2.5, 4 MPa
Precision: 5 %
Electromagnetic flowmeter type PEM-500 is applicable to the measurement of flow of the liquids with minimum conductivity of 5ěS/cm. Device measures flow and volume of liquids in both directions ...
Mass flow rate: 10 kg/min - 800 kg/min
Process temperature: -196 °C - 350 °C
Process pressure: 0 bar - 462 bar
... 1.4410, Tantalum – UNS R05200 Process Connection: 1 ¼" up to 3" General Specifications Serial Tube / Single Path Flow rates Qmax, Qnom and Qmin for "serial" sensors will be 50% of the above listed parallel/dual ...
Rheonik Messtechnik GmbH
Volumetric flow rate: 0 l/min - 3,000 l/min
Process temperature: -50 °C - 300 °C
Process pressure: 10 bar - 40 bar
Flowmeter for liquids and gases high accuracy product specific scale several options Operation: The instruments, type SC-250, are variable area flowmeter.
Volumetric flow rate: 50 l/min - 25,000 l/min
Process temperature: -20 °C - 120 °C
Process pressure: 12 bar
... positive displacement flowmeters offer a high level of accuracy and repeatability. These precision meters are used for flowrate measurement in flow monitoring, control applications and ...
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 10 bar
Precision: 2 %
... VPFlowScope M can be installed under pressure and measures (bi-directional) flow, pressure, temperature, and total flow simultaneously. The flow meter is an all-in-one ...
Process temperature: -40 °C - 150 °C
Process pressure: 0 bar - 16 bar
Precision: 2 %
... Save time and money with this 4-in-1 sensor: measure (bi-directional) flow, pressure, temperature, and total flow simultaneously. The patented VPFlowScope® DP is the ultimate measurement ...
Volumetric flow rate: 0.5 m³/h - 3,000 m³/h
Process temperature: -40 °C - 350 °C
Process pressure: 400 bar
... float-type flow meters are ideal for applications with high temperatures and pressure conditions (pressure up to 400 bar, temperature -40 °C to +350 °C) and for measurement of cloudy and corrosive media. Applications: The ...
MECON
Process pressure: 0 bar - 16 bar
... mass flow meter for DN50 - DN700 (2" - 28") and up to 16 bar (232 psi) The EE776 is a thermal mass flow meter dedicated for monitoring ...
Process temperature: 40 °C - 230 °C
Precision: 1 %
Repeatibility: 0.25 %
SITRANS FS290 is a portable ultrasonic flowmeter system for monitoring volumetric flow in pipes. It contains the SITRANS FST090 battery-operated transmitter and SITRANS FSS220 clamp-on sensors. Install ...
Siemens Process Instrumentation
Volumetric flow rate: 10 l/h - 60,000 l/h
Process temperature: -40 °C - 150 °C
Process pressure: 10, 16 bar
Flow measuring and volume totalization of condensated steam and fuel, tank filling. Widely used in oil industry, measurement of honey, chocolate, paint, resin, inks, etc. Materials Body: EN 1.4404 (AISI 316L), PVC, ...
TECFLUID
Process temperature: -100 °C - 350 °C
Process pressure: 0 bar - 430 bar
Precision: 0.1, 0.5 %
... F-Series flow meters are the preferred choice for process control applications. Choose these smart meters to more efficiently run your process and resolve your toughest productivity challenges Features ...
Micro Motion
Volumetric flow rate: 200 us gal/min - 500 us gal/min
Process pressure: 300, 1,000 psi
Precision: 2 %
The LN series has the following characteristics and/or options: Local indication of flow rate Mechanical pointer Mechanical switch No up or downstream pipe length requirements
UNIVERSAL FLOW MONITORS
Process temperature: -10 °C - 120 °C
Process pressure: 0.6 MPa - 4 MPa
Precision: 0.5 %
... coil, the following electromotive E is generated in proportion to flow speed v: Where: E-Induced electromotive force K-Meter constant B-Magnetic induction density V-Average flow ...
Supmea Automation
Process temperature: -200 °C - 1,240 °C
Process pressure: 0 bar - 160 bar
Precision: 1, 0.5 %
... deltaflows high tolerance on non ideal flow profiles ensures high accuracies even under short inlet conditions. Typical applications are flow measurement of steam, the metering of perssurized air, ...
Volumetric flow rate: 500 m³/h
This is a volumetric immersible electromagnetic flowmeter that applies Faraday's law of electromagnetic induction to measure flow. It is ideal for use with liquids and slurries having a conductivity above ...
Azbil
Volumetric flow rate: 0 m³/h - 1,130 m³/h
Process temperature: -20 °C - 180 °C
Process pressure: 10, 16, 25, 40 bar
... The intelligent flow sensors of the induQ® series work according to the induction principle: the measuring pipe is surrounded by a magnetic field (B). If an electrically conductive medium with the flow ...
SIKA
Process temperature: -25 °C - 60 °C
Process pressure: 10 bar - 16 bar
... liquid to be tested is ≥5μs/cm. It can be used to measure the flow of various acids, alkalis, salt solutions and mud, pulp, pulp and other media with various lining materials. ● The flow measurement ...
Shandong Hetong Information Technology Co.,Ltd.
Process temperature: -20 °C - 60 °C
Process pressure: 0.25 bar - 4 bar
... Adaptation: it can be easily adapted to the mainstream industrial diaphragm gas meters and flowmeters in the market. Full Coverage: 4G full netcom module is selected with high speed ...
HANGZHOU INNOVER TECHNOLOGY CO., LTD.
Process temperature: -5 °C - 700 °C
Sensors offers exhaust flow meters for the measurement of total raw exhaust mass flow from either compression or spark ignition engines and vehicles. All of our EFMs operate under Bernoulli’s ...
Sensors Europe
Process temperature: -25 °C - 60 °C
Precision: 1 %
Repeatibility: 0.2 %
Series DUS-TT-PC wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art ...
Prisma Instruments
Process temperature: -25 °C - 130 °C
Process pressure: 1 MPa - 4 MPa
Repeatibility: 0.5 %
The electromagnetic flowmeter (EMF) can be used to accurately measure the flow of liquid, pulp, slurry and ore pulp with conductivity greater than 5 μS/cm. The AF2000 integrated EMF is a flow ...
Process temperature: -20 °C - 70 °C
Process pressure: 16 bar
... existing and future systems • Robust ultrasonic water meter with smart metering Real data provider for decision-making: • Digital interface: volume, alarms, lifetime, temperature & reverse flow • ...
INTEGRA Metering AG
Process temperature: -40 °C - 80 °C
Process pressure: 150 psi
Precision: 1 %
... Integrates flow-range adjustments, and meter validation and diagnostics Gives you the ability to “field-validate” your meter’s calibration ow does a thermal mass flow ...
Process temperature: -45 °C - 80 °C
Precision: 0.2, 0.5 %
... magnetic flow meter can reach 0.2%. 2. Wide measurement range: electromagnetic flow meter can measure the flow of various fluids, applicable to a ...
Volumetric flow rate: 16 l/h - 40,000 l/h
Process temperature: 200 °C
Precision: 2 %
Glass tube Rotameters are variable area flowmeters for measuring volumetric flow rates of liquids and Gases. The construction includes a tapered glass tube with a float moving inside it. The float position ...
Volumetric flow rate: 0 m³/h - 800 m³/h
Process temperature: -20 °C - 110 °C
Process pressure: 86,000 Pa - 106,000 Pa
digital turbine flow meter is a velocity meter used to measure the volumetric flow and total volume of low-viscosity gases in closed pipelines. It has a wide range of ...
Xi'an Yunyi Instrument Co., Ltd.
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining