- Electricity - Electronics >
- Energy: Production and Distribution >
- Dry transformer
Dry transformers
Electric power: 11,000 W
Primary voltage: 230, 400 V
Secondary voltage: 400 V
ECT11000/IRC Three-phase energy-efficient isolating transformer (BTE) - IP00 - Low Inrush current - Upri 230V ∆ - 400V Y+N // Usec 400V Y+N - Power 11000VA Preparing to set up a charging station at home. Electric ...
EREA Transformers
Electric power: 9, 3, 6, 15 kVA
Primary voltage: 480 V
Secondary voltage: 208, 120 V
Acme’s low voltage distribution transformers are designed for industrial and commercial applications. All of Acme’s general purpose transformers are rated for 600 volts and below. Encapsulated units are ...
Acme Electric
Electric power: 0 kVA - 25,000 kVA
Secondary voltage: 36 kV
ELTAS A.S cast resin dry type transformers are produced up to 20000 kVA with maximum voltage level 36 kV and 250 kV impulse level. TECHNICAL SPECIFICATIONS Low Voltage Coils Foil coil technology is ...
ELTAŞ TRANSFORMATOR San. ve Tic. A.S.
Electric power: 500 kVA - 15,000 kVA
Primary voltage: 15,000, 22,000 V
... demand of safety for the power distribution equipments, dry type transformer with fire resistant, non-polluting and humidity resistant features are often the right choice. AEC's cast resin transformer ...
Elektrotechnik's controllable transformer is a ready-to-connect power supply solution. This transformer aids in providing a power supply either as a 24V control voltage or 8000 V anode voltage. The manufacturer ...
J. Schneider Elektrotechnik
Output power kVA: 3 kVA - 2,500 kVA
Primary voltage: 250 kV
Secondary voltage: 600 V
Applications • Machinery equipment • IC Semiconductor • SMT/PCB electronic assembly • Internet communication system • Military control system • Data processing system • Automatic testing system • Safety monitoring system • Precision ...
Riye Electric
Electric power: 0.005 kVA - 0.03 kVA
Primary voltage: 5 V - 3,200 V
The LV current transformer series manufactured by ENTES, is a set of models that are specially made to transform primary currents by a ratio to its secondary side with 0 degree phase difference. The network's HV side ...
ENTES
Primary voltage: 115, 230 V
Secondary voltage: 12, 24 V
Secondary current: 1.3, 2.5 A
Transformer Double-isolated transformer 3.75 kVAC isolation voltage 30 VA ring core transformer Thermal overload protection 12 or 24 VAC secondary voltage ...
Output power kVA: 30 kVA - 10,000 kVA
Frequency: 50, 60 Hz
The safety and security of tamper-proof padmount transformers make them the ideal choice for installations which may be accessible by the public, or any situation where underground cabling is preferred. Maddox tamper-proof, ...
Primary current: 0 A - 2 A
Secondary current: 0 mA - 2 mA
Frequency: 50 Hz
Mini Voltage Transformer Occasion of use: Generally used in instruments and meters with high space requirements for testing voltage, electric energy and power; Principle of use: Primary and secondary 2 mA: 2 mA current, ...
Jiangyin Spark Electronic Technology Co.,LTD
SES Current Transformers (CT) are used to ensure that electrical systems do not overload and for monitoring large loads by the using a metering instrument. Selection of accurate and reliable CTs are very crucial. It has ...
Success Electronics & Transformer Manufacturer Sdn
Transformers of models EI and EE are applied in a wide range and offer ahigh working frequency and wide range of working voltages plus strong output power and good ability in thermal stability。They have been widely used ...
Primary current: 15, 20, 5, 10 A
Secondary current: 2 mA - 20 mA
Frequency: 50, 60 Hz
CURRENT TRANSFORMERS FOR ELECTRONIC ENERGY METERS FEATURES: -Adopted high permeability core, high accuracy, excellent linear performance; -Anti-combustion plastics case; -Encapsulated with epoxy resin with strong ...
Yueqing RunEasy Electronic Technology Co.,Ltd.
Transformers for switched sources are becoming more relevant in our production chain. These transformers are used in different applications and sectors. The types of switching power supplies are different ...
Transformadores JESIVA,S.L.
Electric power: 0.144, 0.096, 0.06, 0.12 kVA
Secondary voltage: 1.2, 0.8, 0.5 V
Primary current: 120, 0.6 A
... high allowable load impedance and high accuracy enable the CTS transformer to be rigidly integrated with a meter testing system. Once integrated, it can handle both self-contained and transformer connected ...
Primary voltage: 1,200, 720 V
Primary current: 40 A - 7,500 A
Secondary current: 1, 5 A
... current transformer range, these measuring transformers convert high current into lower nominal current value, thus making it possible to use instruments and relays with standardised values of rated current. Part ...
DEIF
Electric power: 0.04 W - 5 W
Primary voltage: 230, 400 V
Secondary voltage: 24 V - 230 V
... isolating / isolation transformers, which are protected against direct contact. Products in the LH-series are designed with maximum versatility in every transformer’s functions and technical features. ...
Muuntosähkö Oy - Trafox
Output power kVA: 0.063 kVA - 20 kVA
Primary voltage: 230 V
Secondary voltage: 24 V
Output power kVA: 0.03 kVA - 2.5 kVA
Primary voltage: 230 V - 400 V
Secondary voltage: 24 V - 230 V
... SINGLE PHASE ISOLATING TRANSFORMERS IP00 Modern and economical make of general purpose isolating and/or safety transformers for building into installations and industrial or power engineering devices. ...
BREVE-Tufvassons
Primary voltage: 220 V - 575 V
Secondary voltage: 23 V - 240 V
The HSZ series of industrial control transformers are designed for applications requiring special mounting and are available in ratings from 1 through 10 kVA.
SolaHD
Primary voltage: 110 V - 240 V
Secondary voltage: 24, 48, 110, 220 V
Secondary current: 10 A - 10,000 A
Internal isolation transformer at input, Full controlled conventional rectifier, Smart control and high reliability with DSP (Digital Signal Processor)... GENERAL SPECIFICATIONS Internal isolation transformer ...
Tescom
Output power kVA: 50 kVA - 2,500 kVA
Secondary voltage: 1.1 kV - 36 kV
Frequency: 50, 60 Hz
STD Cast Resin Transformers have at least one of the two windings embedded on an autoclave mould, at vacuum values close to zero with epoxy resin. The other winding can also be cast in H class. STD Cast Resin Transformers ...
... case current transformers are used if high currents are to be recorded and further processed. The line to be measured (conductor rail or wire) is fed through the window opening and forms the primary circuit for the plug-on ...
Janitza electronics GmbH
Economical Low leakage inductance and interwinding capacitance Fast rise time: 3nSec typical Low profile 16-pin DIP (14-pin available) Surface mount design available Choice of turns ratio, 1:1 or 2:1
Electric power: 0 W - 0.675 W
Primary voltage: 20 V - 30 V
Secondary voltage: 32.1 V
application: Digital two-wire transmitter converts Pt-100, DIN EN 60751 measuring resistors into a 4…20mA current signal. For installation on a standard rail according to EN50022 (DIN, top hat rail). Case:Plastics Case dimensions:B ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining