Primary voltage: 36 kV
... advantages of Cast Resin Traction Transformers are described below: • Worldwide Rail System References, • Working with Global Partners for Railway Applications in the World, • Leader Manufacturer of Customize ...
Aktif Muhendislik Dis Tic. AS.
Output power kVA: 3 kVA - 200 kVA
Primary voltage: 0 V - 600 V
Secondary voltage: 0 V - 600 V
... applications. In CIC’s low-voltage Cast Resin Dry Type Transformers (CRT), coils are cast in epoxy resin (Class F insulation). These transformers, with excellent insulation, are self-extinguishing ...
CHALLENGE INDUSTRIAL CO., Ltd
Electric power: 0 kVA - 25,000 kVA
Primary voltage: 36 kV
These are transformers used in step-down distribution Networks either unloaded or with a load graduality up to a maximum power of 25000 kVA 36 kV. They are manufactured in dry or oil forced types. The ...
Sönmez Transformer Company
Electric power: 11,000 W
Primary voltage: 230, 400 V
Secondary voltage: 400 V
ECT11000/IRC Three-phase energy-efficient isolating transformer (BTE) - IP00 - Low Inrush current - Upri 230V ∆ - 400V Y+N // Usec 400V Y+N - Power 11000VA Preparing to set up a charging station at home. Electric ...
EREA Transformers
Electric power: 0 kVA - 25,000 kVA
Secondary voltage: 36 kV
ELTAS A.S cast resin dry type transformers are produced up to 20000 kVA with maximum voltage level 36 kV and 250 kV impulse level. TECHNICAL SPECIFICATIONS Low Voltage Coils Foil coil technology is ...
ELTAŞ TRANSFORMATOR San. ve Tic. A.S.
Electric power: 500 kVA - 15,000 kVA
Primary voltage: 15,000, 22,000 V
... demand of safety for the power distribution equipments, dry type transformer with fire resistant, non-polluting and humidity resistant features are often the right choice. AEC's cast resin transformer ...
Secondary voltage: 1, 5 V
Primary current: 1, 5 A
... outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer ...
BEIJING GFUVE ELECTRONICS CO.,LTD.
Primary current: 5 A - 1,000 A
- Donut and Terminal Style that Reduce High AC Current Signals to 5 AC Amperes - Model 186 Reduces High AC Current Signals to 10 AC Volts
Primary current: 5 A
Model :CMCT102 Rated Input Current :5A Rated Output Current :2.5mA Turns Ratio :2000:1 Phase Angle Error :≤20'(Input 1A,sampling resistor 100Ω) Linear Range :0~20A(sampling resistor 100Ω) Mounting :Ø5.0mm
Cheemi Technology Co., Ltd
Primary current: 160 A
... suppressor built in. Application: used for the current measuring, monitoring and protecting of AC motor, lighting equipment and air compressor.
YHDC Dechang Electric
This linear current transformer series, allow to obtain an AC or DC voltage on output without other transducer. This solution reduce the cost and space of the installation. Mechanical dimension and primary current ...
F.C. Misure
Primary voltage: 230 V
Secondary voltage: 4 V - 12 V
Bell transformer ZTR-15-12Designated for general use – e.g. as home bells supply, door locks supplyDESCRIPTION Short-circuit-proof, doubled output terminalsTECHNICAL PARAMETERS Input voltage: AC 230 V Output ...
ELKO
Output power kVA: 0.16 kVA - 16 kVA
Frequency: 50 Hz - 60 Hz
... manufacture JSG series three phase transformer with voltage between 160VA and 16KVA.The figure and installation size have be standardized and can be used together with 4AP series of Siemenfs. JSG series transformer ...
Shanghai Leipold Electric Co., Ltd.
Output power kVA: 0.063 kVA - 20 kVA
Primary voltage: 230 V
Secondary voltage: 24 V
Primary voltage: 230 V
Execution in accordance to VDE 0570 / EN 61558 Prepared for units to protective class II Protective type IP 00 Thermal class E Nominal ambient temperature ta 40°C Input voltage: 230V Output voltage: up to 42V Frequency: 50/60Hz Impregnation Test ...
Electric power: 15,000 W - 550,000 W
Primary voltage: 1,000 V
Frequency: 50, 60 Hz
... . • Auto Starter Transformer : Auto Starter Transformer for reduced voltage starting of motors • Standard : BS4941, BSEN60947 • Input Voltages : Up to 1000V AC • Voltage Taps : 50%, 65%, 80% as ...
Boardman Transformers
Elektrotechnik's controllable transformer is a ready-to-connect power supply solution. This transformer aids in providing a power supply either as a 24V control voltage or 8000 V anode voltage. The manufacturer ...
J. Schneider Elektrotechnik
Output power kVA: 3 kVA - 2,500 kVA
Primary voltage: 250 kV
Secondary voltage: 600 V
Applications • Machinery equipment • IC Semiconductor • SMT/PCB electronic assembly • Internet communication system • Military control system • Data processing system • Automatic testing system • Safety monitoring system • Precision ...
Riye Electric
Electric power: 0.005 kVA - 0.03 kVA
Primary voltage: 5 V - 3,200 V
The LV current transformer series manufactured by ENTES, is a set of models that are specially made to transform primary currents by a ratio to its secondary side with 0 degree phase difference. The network's HV side ...
ENTES
Primary current: 100, 1,000 A
Measuring power electronics at medium and high frequencies Applications: Plasma excitation Laser excitation Ultrasonic excitation Induction heating Induction cooking High speed spindles Avionic power supplies (including harmonic ...
Output power kVA: 30 kVA - 10,000 kVA
Frequency: 50, 60 Hz
The safety and security of tamper-proof padmount transformers make them the ideal choice for installations which may be accessible by the public, or any situation where underground cabling is preferred. Maddox tamper-proof, ...
Primary current: 0 A - 2 A
Secondary current: 0 mA - 2 mA
Frequency: 50 Hz
Mini Voltage Transformer Occasion of use: Generally used in instruments and meters with high space requirements for testing voltage, electric energy and power; Principle of use: Primary and secondary 2 mA: 2 mA current, ...
Jiangyin Spark Electronic Technology Co.,LTD
SES Current Transformers (CT) are used to ensure that electrical systems do not overload and for monitoring large loads by the using a metering instrument. Selection of accurate and reliable CTs are very crucial. It has ...
Success Electronics & Transformer Manufacturer Sdn
Transformers of models EI and EE are applied in a wide range and offer ahigh working frequency and wide range of working voltages plus strong output power and good ability in thermal stability。They have been widely used ...
Primary current: 15, 20, 5, 10 A
Secondary current: 2 mA - 20 mA
Frequency: 50, 60 Hz
CURRENT TRANSFORMERS FOR ELECTRONIC ENERGY METERS FEATURES: -Adopted high permeability core, high accuracy, excellent linear performance; -Anti-combustion plastics case; -Encapsulated with epoxy resin with strong ...
Yueqing RunEasy Electronic Technology Co.,Ltd.
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining