- Electricity - Electronics >
- Energy: Production and Distribution >
- Dry transformer
Dry transformers
Current Transformers MPR Family Accessories Temperature range: -40 +70 °C Box made with self-extinguishing material UL 94-VO Test voltage between primary and secondary: 4Kv
Orion Italia
Electric power: 0.4, 0.5, 0.005, 0.06 kVA
Primary voltage: 3,000 V - 35,000 V
Secondary voltage: 100, 110, 120 V
... Silko CT and VT series are high-voltage instrument transformers that are suitable for use in measuring and protecting high-voltage distribution systems of 3.6kV up to 40.5kV. In addition, these transformers ...
Electric power: 0.01 kVA
Secondary voltage: 4, 8, 12 V
10VA transformer for continuous service, outputs 4-8-12V 2 DIN Power supply 230V a.c. – 50Hz Outputs 4-8-12V Installation on terminal board IP20 Wall-mounted IP30 Installation on the rear of the switchboard IP40 Dimensions ...
Electric power: 3,000 W - 250,000 W
Primary voltage: 220 V - 440 V
Secondary voltage: 110 V - 254 V
Our Transformer's Feature: Internal coil is made of a special varnish electrical insulation paper, that is sturdy mechanical support structure caused, for the impact of the circuit and so have sufficient endurance. Use ...
YU CHENG POWER CO.,LTD
Electric power: 7, 15 W
Main Features Designed for severe enviroment SESI technology Typical Applications Power Supply
EXXELIA
Electric power: 60,000 kVA
Primary voltage: 161 kV
Product Item : 161KV SF6 Insulated Power Transformer Specification : Max. actual performance capacity: 60MVA. Features: 1. Technical transfer, self-development and 3D software application. 2. Well-based self-inspection ...
Shihlin Electric & Engineering Corporation
... neutral cables should be passed through the toroidal transformer. The ground wire must not pass through the toroidal transformer. The cables should be routed through the center of the toroidal transformer ...
SIGMA ELEKTRIK
Primary voltage: 5.4, 3.1 V
Primary current: 0.08, 0.05 A
This product is an ultra compact audio frequency transformer for use on a printed circuit board. It is packed in a self-extinguishing plasitic case, and the size is very compact., but as it uses the DL core developed ...
Tamura Corporation
Primary voltage: 480 V
Secondary voltage: 208 V
Primary current: 416 A
... identify potential overload conditions before you add new servers. Reduce operating costs with NEMA-rated, TP-1 isolation transformers. Status available to customers both in the data center and remotely Enables remote ...
Electric power: 40 W
Primary voltage: 12 V - 250 V
Primary current: 1 A
Non-Contact Current Transformer Enhance your Smart Grid A non-contact current transformer measures three-phase current at line voltages to protect power systems and to provide critical real-time information ...
The very compact ELEQ TQ30 split-core current transformer is especially designed for connection to digital measurement systems. The TQ30 is supplied with color coded secondary leads. All current transformers ...
ELEQ
Electric power: 0.03 kVA - 4 kVA
Primary voltage: 100 V - 690 V
Secondary voltage: 12 V - 250 V
Designed and tested according to: • IEC/EN 61558-2-2 • VDE 0570-2-2 • UL 506 • CSA 22.2 no. 66 For use according to: • IEC/EN 60204-1 / ÖVE EN13 • VDE 0113 / VDE 0100 part 410 Typical applications: • Control voltage ...
Trafomodern Transformatorengesellschaft
... are safe from finger-touch are provided for connection. Single-Phase Standard Transformers to VDE 0570/IEC 615588 •Power range 2,5 – 20 kVA •Core-type transformer •Frequency 50/60 Hz •Base bracket ...
Getra
Grid transformers are used in similar situations to autotransformers but are used where the neutral point of both HV and LV system are required to be kept separately. They are physically larger than a correspondingly ...
Smit Transformatoren
Electric power: 1 kVA - 160 kVA
Primary voltage: 950 V - 6,600 V
... Single-phase sets for sigle-phase networks : 1 to 50 kVA o Single-phase transformers for three-phase networks : 1 to 50 kVA o Three-phase transformers for three-phase networks : 5 ...
Augier
Primary voltage: 115 V - 460 V
Secondary voltage: 333 mV
Primary current: 4 mA - 20 mA
Magnelab SPT-0375 Transformer When you are asked what is a potential transformer, simply show them the SPT-0375 voltage transformer. It offers output AC voltage that is linearly proportional ...
Manutech Europe
Secondary voltage: 1, 5 V
Primary current: 1, 5 A
... outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer ...
BEIJING GFUVE ELECTRONICS CO.,LTD.
Electric power: 30 W - 30,000 W
Primary voltage: 230, 400 V
Secondary voltage: 48, 12, 24 V
Compliant with standard EN 61558-2-6 • Standard voltages • Other voltages available on request • Electrostatic screen available on request • Ambient temperature 40 °C • Protection rating IP00 • Electrical protection rating I • ...
ced
Electric power: 100 kVA - 3,150 kVA
Primary voltage: 24 kV
Secondary voltage: 1,000 V
CELME's transformers have been installed on distribution network and energy production plant, suitable both for standard environmental condition or for high critical ambient and the Cast Resin Transformers ...
Primary voltage: 0.6 kV
1 - Current transformers : from low voltage up to 36 kV - wire wounded or ring type - indoor or outdoor - single or multiple cores - ratio, accuracy and burden on demand
Primary current: 100 A - 5,000 A
Frequency: 60, 50 Hz
• Primary current: 100A-5000A • Sercondary current: 5A, 1A • Standard approval: IEC44-1, BS7626, VDE0414, VL94 • Maximum voltage: 0.72/3kV • Frequency: 50/60Hz • Rated load: 1VA-30VA • Class: 0.5, 1.0, 3.0 • Short-time thermal ...
Yueqing Hean Electrical Co., Ltd.
Primary current: 0.1 A - 1,000 A
This product is a combined current transformer that can simultaneously detect lightning current and AC high current. The two-way current inputs and outputs are completely isolated, with high isolation voltage. The product ...
Primary current: 5 A - 600 A
We produce supporting type current transformers for indoor installation. They contain up to five cores for revenue metering and protection purposes, constructed from high quality siliceousor nickel steel laminations. ...
TWB SA
LMK3-0.66 series transformer is indoors type current transformer,is applicable for circuit of rated frequency 50Hz or60Hz,rated voltage is 0.66kV and below. It is used to transmit signal to measure meter,or ...
PEOPLE ELE. APPLIANCE GROUP CO., LTD.
Primary voltage: 115, 230 V
Secondary voltage: 115, 230 V
... recorded by grounded instrumentation might be powered by an isolation transformer secondary to primary either insulated by potting, oil or air. The low dielectric constant of air insulation provides lower ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining