- Electricity - Electronics >
- Energy: Production and Distribution >
- Electrical power supply transformer
Electrical power supply transformers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Output power kVA: 0.025 kVA - 2.5 kVA
Primary voltage: 230 V - 400 V
Secondary voltage: 24, 230, 115 V
Safety and circuit separation transformers from 25 to 2500 VA Universal range 25 VA to 2500 VA - Double winding Fixing on omega rail (depending on model) or panel (screw) Secondary earthing by plug-in jumpers (depending ...
Primary voltage: 115, 230 V
Ignition transformers for high-voltage ignition of gas or oil burners, suitable for ignition and control with one electrode. Features & Benefits: Ignition voltage: 5 to 8 kV Duty cycle: 19 to 33% or continuous ...
Step-up transformers are cohesive coils consisting of primary coils and secondary coils, and generate voltage that corresponds to turn ratios with mutual induction effects. TDK’s step-up transformers ...
Electric power: 0.1, 0.125, 0.15, 0.02 W
Primary current: 0.3 mA - 5,200 mA
Frequency: 400 Hz - 250,000 Hz
... -PRF-27, Grade 5, Class S. FREQUENCY RESPONSE:±3db, 400 Hz - 250 KHz at 1.0 Milliwatt. MAXIMUM DISTORTION: 5% With Rated Power Level at 1 KHz and 400 Hz. DIELECTRIC STRENGTH: All Units Tested at 200 V RMS. INSULATION ...
Electric power: 0.075 W - 0.83 W
Frequency: 400 Hz - 100,000 Hz
MIL-PRF-27: All units manufactured to MIL-PRF-27, Grade 5, Class S. DIELECTRIC STRENGTH: All Units Tested at 200 V RMS. INSULATION RESISTANCE: Greater Than 10,000 Megohms at 300 V DC. WEIGHT: 2.5 Grams. OPERATING TEMPERATURE: -55º ...
Primary voltage: 26, 115 V
Frequency: 400 Hz
Manufactured to MIL-PRF-27, Grade 5, Class S. 90º C Ambient. Regulation is 24% (T Units Have Regulation of 17%) Secondary Voltage Adjusted to Nominal Value at Half Load. Smallest Possible Size. Printed Circuit Thru Hole Construction. Secondary ...
Electric power: 160,000 W
Primary voltage: 400 V
Secondary voltage: 480 V
Split- winding transformer Split-winding transformer separate the low voltage winding into 2 isolated parts, each winding can work individually or together. The advantage of the transformer. 1)Reduce ...
Electric power: 1,000 W - 1,000,000 W
Primary voltage: 220 V - 660 V
Secondary voltage: 5 V - 600 V
... loads generate harmonic currents that cause transformers and system neutrals to overheat, which can destroy the transformer. When a non-linear load is supplied from a transformer, ...
Electric power: 0.1 kVA - 0.4 kVA
Primary voltage: 208 V - 480 V
Secondary voltage: 220 V
ATS Transformer Module is designed with pluggable terminal block to simplify ATS installation. Best use for system voltage 208 to 480 Vac. For system voltage from 208 to 480 Vac Modular design, simplify ATS ...
Output power kVA: 0.005 kVA
Primary voltage: 120 V
Secondary voltage: 12 V
Input Voltage: 120V AC Output Voltage: 12V AC Rated Power: 50VA Core Material: High Permeability Silicon Steel Dimensions: Inner Diameter (I.D.): 70 mm - Outer Diameter (O.D.): 90 mm, Height: 20 mm
Output power kVA: 0.3 kVA
Primary voltage: 220 V
Secondary voltage: 12 V
Our 300VA Toroidal Transformer is the ideal solution for your power supply needs. With an output of 12V AC and a power rating of 300VA, this transformer ...
Output power kVA: 100 kVA - 20,000 kVA
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
... Compared to the existing EcoDesign Tier2 Transformers set by the European Community, EcoPlus2030 Transformers boast significantly reduced CO2 emissions and losses. Just like the olive tree, our EcoPlus2030 ...
Tesar Srl
Frequency: 60, 50 Hz
... the supply of cast resin transformers mainly used for energization of rails, metros, highspeed trains, tram- ways, braking energy recovery systems and auxiliary services for sta- tions ...
Tesar Srl
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
Frequency: 50 Hz - 60 Hz
Tesar offer a wide range of customized solutions for feeding Data Centres: • Transformers with K factor up to 20 (high harmonic content) • Electrostatic screen between primary and secondary • Simplified Busbars connection ...
Tesar Srl
Electric power: 50 W - 2,000,000 W
Primary voltage: 1 V - 1,000 V
Secondary voltage: 1 V - 1,000 V
The single-phase and three-phase transformers and auto-transformers are equipped with either copper or aluminum windings. These units feature air-type cooling and can perform up to 2000 kVA, with a frequency ...
Electric power: 50 W - 2,000,000 W
Primary voltage: 1 V - 1,000 V
Secondary voltage: 1 V - 1,000 V
Our 1-Ph and 3-Ph insulation transformers are designed to meet the following priority requirements: Anti-jamming screening between the primary and secondary windings Cooling: air type Power: up to ...
Output power kVA: 0.05 kVA - 2.5 kVA
Primary voltage: 15 V - 400 V
Secondary voltage: 24, 48, 110, 230, 12 V
... Temperature : 40 Transformer Circuit Protection Transformers must be protected against short circuit and overload. Primary Circuit The primary side of the Transformer should be ...
Output power kVA: 0.05 kVA - 2.5 kVA
Primary voltage: 220 V - 415 V
Secondary voltage: 12, 230, 115, 48, 24 V
... Temperature : 40℃ Transformer Circuit Protection Transformers must be protected against short circuit and overload. Primary Circuit The primary side of the Transformer should ...
Primary voltage: 72 kV - 800 kV
... elements are subject to low electrical stress with high stability under extreme temperature variations. Applications • Revenue metering • Protective relaying • System control and indication of power ...
Primary current: 1 A - 5,000 A
... come up to. The new Compact Optical Sensor Intelligence, with Full IEC 61850 compliant and caters to both AC (up to 1200kV) and DC (up to 800kV). It contributes to Smarter Grids Networks to bring about changes for the ...
Electric power: 90,000 W - 180,000 W
... Using the latest state-of-the-art technology and newest trends in the power electronics field and digital control, the APOJET AJT offers the best solution for aircraft ground power supply ...
Output power kVA: 0.01 kVA - 0.25 kVA
Primary voltage: 4 V - 250 V
Secondary voltage: 24 V
... 88 Series Transformers provide low voltage source from 50 to 250 volt amps for all large signaling installations. Holes provided in transformer housing for surface mounting. The Edwards 88 Series ...
Classification: Amorphous alloy phase-shifting rectifier transform
Chongqing Xianglong Electric Co., Ltd
Primary voltage: 115, 230 V
Secondary voltage: 12, 24 V
Secondary current: 1.3, 2.5 A
... transformers may be paralleled for higher output power. Application Transformer for supply of components with 12 or 24 VAC supply voltage. Transformer ...
Transformers for switched sources are becoming more relevant in our production chain. These transformers are used in different applications and sectors. The types of switching power supplies ...
Transformadores JESIVA,S.L.
Electric power: 6,400 W
Primary voltage: 450 V
Secondary voltage: 46 kV
6.4kW High Voltage Transformer Rectifier outputting 10-50 kilovolts. Direct Current - 6.4 kilowatt. Specification Power rating6.4kW Frequency of operation20kHz Output voltage46kVDC ...
Genvolt
Primary voltage: 230 V
Secondary voltage: 6 V - 115 V
Frequency: 50, 60 Hz
... the TE model range toroidal transformers as standard up to 7500 VA. The transformers can also be customized with a speedy delivery to correspond to the customer’s requests and standards. The power ...
Muuntosähkö Oy - Trafox
Electric power: 1,500, 2,000, 3,000, 5,000 kVA
Primary voltage: 230, 480 V
Secondary voltage: 110, 115, 120 V
... Encapsulated industrial control transformers are epoxy encapsulated to seal the transformer windings against moisture, dirt and industrial contaminants. Extra deep, molded terminal barriers reduce the ...
SolaHD
Electric power: 0.0006 kVA - 0.0032 kVA
Primary voltage: 24 V - 440 V
Secondary voltage: 6 V - 24 V
... short-circuit-proof vaccum encapsulated, bobbin with dual chamber windings temperature class ta 40C/F and ta 70C/F hight electrical safety and long service-life properties quality test certified per item excellent temperature ...
HAHN - Elektrobau
Electric power: 185 W - 3,000 W
Output power kVA: 40 kVA - 2,500 kVA
Primary voltage: 24 kV
The transformers can be available with oil expansion tank or hermetic version , and they are designed and manufactured according the following standards and equipped by the following accessories: • CEI EN 60076-1:2015 ...
Primary voltage: 230, 115 V
Frequency: 50 Hz - 60 Hz
... solder lug or quick connect) C UL US recognized (E207860) CE certified to IEC 950 (Approved to EN 60-742 Safety Isolating Transformers)
Hammond
Output power kVA: 10 kVA
Primary voltage: 600 V
Secondary voltage: 600 V
PhaseSingle FrequencyBased on customers' requirement Capacity10KVA Max. Voltage600V Max. Inductance RangeBased on customers' requirement Insulation LevelClass A / B / F
Leader Electronics Inc.
Output power kVA: 70,000 kVA
Primary voltage: 110 kV
Furnace Transformer up to 110kV up tp 70MVA Product Usage Used for smelting high-quality alloy steel and ferroalloy in the metallurgical industry Used in steelmaking, iron, etc. in the iron ...
Siyuan Electric Co., Ltd
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining