- Electricity - Electronics >
- Electronic Component >
- Electronic filter
Electronic filters
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Frequency: 6,240 MHz - 8,250 MHz
Status - Mass Production (Preferred) System - UWB Input Impedance / Output Impedance - 50 Ω / 50 Ω Dimension L - 1.6 ±0.10 mm Dimension W - 0.8 ±0.10 mm Dimension T - Max 0.65 mm Operating Temp. Range - -40 to +85 ℃ RoHS Compliance ...
Taiyo Yuden
Frequency: 3,300 MHz - 4,200 MHz
Status - Mass Production (Preferred) System - 5G Input Impedance / Output Impedance - 50 Ω / 50 Ω Dimension L - 1.6 ±0.10 mm Dimension W - 0.8 ±0.10 mm Dimension T - Max 0.65 mm Operating Temp. Range - -40 to +85 ℃ RoHS Compliance ...
Taiyo Yuden
Frequency: 4,400 MHz - 5,000 MHz
Status - Mass Production (Preferred) System - 5G Input Impedance / Output Impedance - 50 Ω / 50 Ω Dimension L - 1.6 ±0.10 mm Dimension W - 0.8 ±0.10 mm Dimension T - Max 0.65 mm Operating Temp. Range - -40 to +85 ℃ RoHS Compliance ...
Taiyo Yuden
Frequency: 60 Hz
Voltage: 530, 305 V
Filter for low leakage current application • Low leakage EMC filter with high performance options • Improvement of system reliability • Tight packaged EMC filter • Industry standard ...
TE CONNECTIVITY
Frequency: 30 MHz - 40,000 MHz
... power operation. Each filter is custom-designed to your exact specification so that you will receive the optimum performance at the lowest cost. Standard cavity filters generally are designed using aluminum ...
Smiths Interconnect
Frequency: 24 MHz - 3,000 MHz
... the factory for your specific requirements. An additional feature of our Tunable Filter Product Line is the ability to ship standard bandpass and bandreject filters overnight from stock.
Smiths Interconnect
Frequency: 18 GHz
Planar X Thin Film RF Filter solutions Planar X Series is part of an overarching initiative by Smiths Interconnect that entails the creation of best-in-class planar RF filter solutions designed and tested ...
Smiths Interconnect
Littelfuse common mode noise filters with ESD protection are used to suppress unwanted common mode noise with no adverse effect on the signals (differential cut-off frequency) and also offer additional ESD protection functions.
Frequency: 1 Hz - 500,000 Hz
... The SIM965 Analog Filter is ideal for signal conditioning applications where Bessel or Butterworth filters are needed. Bessel filters offer clean step response (negligible overshoot) ...
... of CISPR22 /EN 55022 Class B. EMC filter used with the MORNSUN AC/DC module, AC/DC module’s max. Input voltage must not more than EMC filter’s max. Voltage, AC/DC module’s max. Input current must less ...
MORNSUN Guangzhou Science & Technology Co.,Ltd.
... requirement of CISPR22 /EN 55022 Class B. EMC filter used with the MORNSUN DC/DC module, DC/DC module’s max. Input voltage must less than EMC filter’s max. Voltage, DC/DC module’s max. Input current ...
MORNSUN Guangzhou Science & Technology Co.,Ltd.
Frequency: 150 kHz - 500,000 kHz
Voltage: 110 V
Primary current: 3.5 A
FEATURES - Meet IEC/EN61000-4 series standards and CISPR32/EN55032 - Meet railway industry EN50155 standards - Efficiency up to 98%
MORNSUN Guangzhou Science & Technology Co.,Ltd.
Frequency: 50, 60 Hz
... AFQs active filters is the most complete and compact solution to solve quality problems caused by harmonics in small and medium power non-linear drives and loads. Like the other ranges, it can also be used in installations ...
CIRCUTOR
Frequency: 60, 50 Hz
Voltage: 480, 400 V
Primary current: 30 A - 400 A
... filtered for maximum filter effectiveness Power factor correction both inductive and capacitive Phase current balancing, improvement of consumption in neutral (4W model) If higher filtering capabilities ...
CIRCUTOR
Frequency: 60, 50 Hz
Voltage: 480, 400 V
LCL filters have been specially designed to eliminate the harmonics from the current absorbed by 6-pulse power converters, such as frequency variators for motors, UPS, etc. These are essentially passive filters ...
CIRCUTOR
Frequency: 100, 900 MHz
noise suppression filters for audio lines of high sound quality devices Bild_w_background_en Support for wide frequency bandpass, extending from the FM band to the cellular band Particularly well-suited for ...
TDK Electronics Europe
Frequency: 0 Hz
Voltage: 24 V
Primary current: 4 A
Filters of the SFK12-4S2124 series are used to suppress circuit-bound interferences in DC supply lines or DC control lines with a voltage of 24VDC. Interference pulses or interference voltages are dampened independently ...
FEAS GmbH
Frequency: 0 Hz
Voltage: 48 V
Primary current: 4 A
Filters of the SFK12-4S2148 series are used to suppress circuit-bound interferences in DC supply lines or DC control lines with a voltage of 48VDC. Interference pulses or interference voltages are dampened independently ...
FEAS GmbH
Frequency: 0 Hz
Voltage: 48 V
Primary current: 8 A
Filters of the SFK12-8S2148 series are used to suppress circuit-bound interferences in DC supply lines or DC control lines with a voltage of 48VDC. Interference pulses or interference voltages are dampened independently ...
FEAS GmbH
Suppressor modules from Murrelektronik ensure machine availability. The benefits of suppressor technology are enormous and far outweigh the measures linked with its deployment. For a small price, you can prevent malfunctions or faults ...
MURRELEKTRONIK
... lower energy loss and lower maintenance costs. Features & Benefits Delta's Active Power Filter APF2000 uses a current transformer to monitor load current and filter harmonics in real-time to maintain ...
Frequency: 150 kHz - 30,000 kHz
Primary current: 150 A - 600 A
DC-Busbar EMC/RFI Filter for EV charging Designed for usage in EV charging applications Ultra-compact filter Multiple performance options Design acc. to EV charging safety standards
Schaffner EMV AG
Frequency: 0.06 kHz
Voltage: 300, 277 V
Primary current: 7 A - 180 A
... attenuation performance from 150 kHz to 30 MHz Excellent saturation resistance up to 50 m cable length Most compact and slim filter design in its class Operating frequency : DC to 60 Hz Rated current : 7 to 180 A Attenuation ...
Schaffner EMV AG
Frequency: 60 Hz
Voltage: 690 V
Primary current: 10 A - 160 A
Standard and high performance EMC solution Footprint space-saving book-style housing Solid safety connector blocks Standard attenuation performance FN 3287 High attenuation performance FN 3288 HV versions for 690 VAC applications HVIT- ...
Schaffner EMV AG
Frequency: 50, 60 Hz
Voltage: 0 V - 250 V
Primary current: 60 A
Characteristics PLC Blocking Filters Single Phase for Smart Meters Specially designed for Smart meters which comply with PLC G3, PRIME & CENELEC Band A technology. Designed to meet according to ...
Frequency: 824 MHz - 5,900 MHz
Pasternack RF bandpass filters (BPF) are tractable coaxial elements that permit particular frequencies to move within a specific distance and declining frequencies (attenuation) beyond that range. Bandpass RF filters ...
Pasternack Enterprises, Inc.
Nominal inductance: L1/L2 11mH Rated current: 5Arms @50Hz Ripple current: L1 4.5Arms @1.5kHz Nominal capacitance: 6.8 uF Rated voltage: 680Vdc Environment : PD3A Weight : 15 Kg Fire/smoke standard: NFPA 130/EN45545-2
Frequency: 50 Hz
Voltage: 380 V
Primary current: 188 A
Sikes passive harmonic filter is designed for almost any kind of electronic applications with six pulse front end rectifiers . The filter can efficiently reduce the harmonic current distortion ...
Shenzhen Sikes Electric Co., Ltd.
Frequency: 50 Hz
Voltage: 400 V
Primary current: 100 A
EMI/EMC filter dedicated for Rail and transportation . The train electrical system is very complex with many big power electrical devices resulting in severe electromagnetic interference . This products is specially designed ...
Shenzhen Sikes Electric Co., Ltd.
Frequency: 50 Hz
Voltage: 400 V
Primary current: 10 A
Optimize harmonic performance Advanced Harmonic Filter PHF 005/010 is a cost-effective total solution. Compared to traditional harmonic trap filters PHF offers a smaller foot print and higher harmonic ...
Shenzhen Sikes Electric Co., Ltd.
Frequency: 50 Hz
Voltage: 300 V - 720 V
Primary current: 6 A - 400 A
Design : Universal horizontal high-performance two-stage filter. Typical Applications Variable speed electric drive systems/motor drives primarily for industrial use. Various industrial applications, ...
SHENZHEN DAQI INDUSTRIAL DEVICE CO.,LTD.
Frequency: 50 Hz
Voltage: 380 V - 520 V
Primary current: 5 A - 200 A
Universal compact thin-walled filter DAQI ® EMC filters are essential devices that prevent interferences in machines and systems. They reduce the interference emissions while improving immunity from internal ...
SHENZHEN DAQI INDUSTRIAL DEVICE CO.,LTD.
Frequency: 50 Hz
Voltage: 300 V - 720 V
Primary current: 1 A - 40 A
... for low current and low power, with small size, light weight, and high cost-effectiveness. EB11 has excellent broadband filtering effect, suitable for broadband strong electromagnetic interference application environment. EB12 ...
SHENZHEN DAQI INDUSTRIAL DEVICE CO.,LTD.
Frequency: 500 kHz
Voltage: 0 V - 50 V
Primary current: 0.8 A
... series of hybrid EMI filters is operable over the full military (-55 °C to +125 °C) temperature range with no power derating. The DVMSA28 EMI filter is designed to filter conducted emissions ...
VPT Inc
Frequency: 50, 60 Hz
Voltage: 380 V - 690 V
Primary current: 5 A - 750 A
Attenuation THDi - < 5% Dielectric test phase – phase - 2400 Vdc (2 sec.) Dielectric test phase – ground - 3200 Vdc (2 sec.) Protection Degree - IP00 integrable in cabinet IP21, IP54 indoor or IP54 outdoor Overload - 4 x Rated current ...
IREM SPA
Frequency: 160 MHz
RRF-160-NFF 160MHz Band Pass Filter PolyPhasers weatherized band pass filter surge protector is designed for 160 MHz railroad wayside applications. Specifically designed for rail PTC systems the RRF-160-NFF ...
Frequency: 60, 50 Hz
Voltage: 300, 520 V
Primary current: 3 A - 20 A
• Line filter as standard, industrial and medical version • 1 stage • Filter with standard or high attenuation (HP) Unique Selling Proposition • Compact single-stage filter • Various ...
SCHURTER
EMI filters are low-pass, band-pass, or high-pass filters combined with ESD protection diodes. They also integrate pull-up and/or pull-down resistors, depending on the application. ST EMI filters ...
Frequency: 60, 50 Hz
Voltage: 208 V - 480 V
Primary current: 20, 320, 40 A
... Energy? • More than 20 years experience in active filtering solutions • Compliance to grid standards and norms • Integration of load balancing, power factor compensation and harmonics filtering ...
Frequency: 10.7 Hz
Murata’s ceramic filter series (CERAFIL®) offers small and lightweight filters and traps that use the piezoelectric properties of ceramics to treat intermediate frequencies used in AV and communication equipment.
Murata Electronics
Frequency: 400 Hz
Voltage: 250 V
Primary current: 16 A
RF filters which provide high attenuation in both differential and common mode. Their extended low frequency performance makes them particularly suitable for industrial frequency converters, motor drives and switch mode ...
RS PRO
Your suggestions for improvement:
An EMI (electromagnetic interference) filter is a passive device designed to suppress power-line interference produced by a device, or to protect a piece of equipment from such interference. Both single- and three-phase protection is possible. Such a filter also can be found on RJ11 connections.
ApplicationsEuropean EMC and American FCC regulations prescribe filters for electrical and electronic gear to ensure electromagnetic compatibility. These norms define filter parameters for communications, network and medical equipment, lighting and machinery. Standards differ between residential and industrial settings.
TechnologiesFilters attenuate radio frequency and electromagnetic interference between the line and the equipment. These devices contain special capacitors and ferrite windings. They can operate in common or differential mode, or both at once. Filters are connected to the power line and are grounded, if in common mode. They also can include surge protection components.
How to chooseChoice will depend primarily on the type and power of the equipment in question. In common mode, leakage current must be considered.
- Compatibility
- Electromagnetic protection
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining