- Electricity - Electronics >
- Switch and Relay >
- Gas-insulated circuit breaker
Gas-insulated circuit breakers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
LW8-40.5 Outdoor AC High Voltage SF6 Circuit Breaker Category:Components
Primary current: 0 A - 3,150 A
VAC: 72.5 V - 145 V
... Zero SF6, Zero greenhouse gases - only clean air The only way to achieve Zero GWP and Zero toxicity is by using clean air. The 3AV1 live tank circuit breaker combines vacuum switching ...
Siemens Energy – Power transmission
Primary current: 2,000 A
VAC: 36, 38, 40.5 kV
... -blast principle. This live tank circuit breaker provides a high level of reliability for customers, even under extreme conditions and climates or in highly active seismic areas. The GL 107X live tank ...
Primary current: 2,500 A
VAC: 52, 72.5 kV
Well proven circuit breaker based on modular design, factory assembled and tested for rapid installations The EDF SK is a live tank SF6 AutopufferTM circuit breaker. ...
... protection. You could either select a higher-cost transformer switch with advanced protection capabilities, like a circuit-switcher or circuit breaker, or you could choose a lower-cost ...
Primary current: 630 A
VAC: 12 kV
... high-voltage AC vacuum circuit breaker is an outdoor pole-mounted switch of vacuum arcing and SF6 insulation. It is featured by small, and excellent climatic protection performance, etc., and it mainly ...
Primary current: 4,000, 5,000 A
VAC: 550, 800, 252, 363 kV
... tightness technology, high design parameters, the whole structure of circuit breaker is compact, with stable and reliable performance and long endurance. 1 The circuit breaker ...
Henan ping high electric co., LTD.
Primary current: 0 A - 2,000 A
VAC: 0 kV - 36 kV
... high altitudes. In low inductive and capacitive currents the SF6 GCB is highly suitable. It continuously supervises the SF6 gas pressure.
CG Power Systems
VAC: 72.5 kV
Transmission , Distribution and Substation 72.5KV Live Tank SF6 Circuit Breaker
Primary current: 400, 630, 800, 1,250 A
VAC: 12 kV
The SWR12 is an OEM designed retrofit circuit breaker for both the South Wales Switchgear C & D range Oil Circuit Breaker and the HG12 Gas Circuit ...
BRUSH Group
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining