- Hydraulics - Pneumatics >
- Valve >
- Gas pressure regulator
Gas pressure regulators
Pressure: 0 bar - 0.7 bar
... or more torches to a single Oweld gas generator. When it is used? It is used in case of multi-torches connected to a single Oweld gas generator. Where it is installed? EPR is installed between ...
Pressure: 31 bar
Orifice diameter: 9 mm - 66 mm
... code. Unlike some competitive models of low side regulators that utilize high pressure discharge gas as a pilot source, they are piloted with upstream pressure. This ...
Parker Refrigerating Specialties Division
Temperature: 0 °C - 50 °C
... , 430 stainless steel and Sandvik® 1802 • Brass Orifice Applications: Volumetric Flow Control Carrier Gas Pressure Control Air over Liquid Flow ...
Parker Precision fluidics Division
Pressure: 241, 27.6 bar
Orifice diameter: 0.25 in
Temperature: -40 °C - 74 °C
... purity single-stage regulator for specialty, flammable, and industrial gas flows of less than 5 SCFM / 141 SLPM. Its diffusion-resistant metal diaphragm seal ensures gas purity and integrity. ...
Emerson Automation Solutions - TESCOM
Pressure: 0.07 bar - 34.5 bar
Flow: 1.7 m³/h
Orifice diameter: 1, 0.25 in
... Series regulators are direct-operated, pressure reducing regulators that resist hydrate formation and regulator freeze-up typically used on high-pressure ...
FISHER REGULATORS
Pressure: 0 bar - 17 bar
Flow: 80 ft³/min
Orifice diameter: 0.25 mm
... diaphragm, insures a constant output pressure even during wide supply pressure variations. Stability of regulated pressure is maintained under varying flow conditions through the use ...
Pressure: 0.01 bar - 9.5 bar
Flow: 0 l/min - 0.02 l/min
Temperature: 5 °C - 50 °C
... high performance auto pressure regulator UR-Z700 Series has electronic regulators with high-precision pressure sensors and high resolution, fast response piezo actuator ...
Pressure: 0 bar - 16 bar
Orifice diameter: 4 mm - 10 mm
Temperature: -10 °C - 70 °C
Parker Legris pressure regulators stabilise at the maximum determined value of the pressure delivered to the pneumatic equipment at any given fluctuations of the pressure ...
Pressure: -1 bar - 40 bar
Temperature: -20 °C - 70 °C
... energy efficiency is improved Control and monitoring according to needs and with no auxiliary energy. Features Switching point can be adjusted Sealable Pressure sensor made of brass for non-aggressive ...
Pressure: 15 MPa
Orifice diameter: 25 mm - 300 mm
Temperature: -20 °C - 60 °C
... pilot-operated regulator which function is to supply constant outlet pressure and ensure supplying flow continually, suitable for all non-corrosive gases after purification treatment. The PL3000 is especially ...
Terrence Energy Co.,Ltd.
Pressure: 0.01 bar - 4 bar
Orifice diameter: 15 mm - 150 mm
* Gas regulator /governor for gaseous media, to be fitted to all types of gas consuming appliances. * Design incorporates inlet pressure compensation diaphragm ensuring ...
Avcon Controls PVT. Ltd.
Pressure: 10,000, 16 mbar
Flow: 13 l/min - 140 l/min
Orifice diameter: 68, 83, 117 mm
... please. Description: he low pressure regulator is manually adjustable. Version R01-2/-3/-4 has an integrated safety valve which opens at a pressure of 1.5 times of the max. outlet ...
AirCom Pneumatic
Pressure: 75.84 bar
Orifice diameter: 6 mm - 15 mm
Single seated and self-actuating compact diaphragm-type regulators covering a wide range of designs and operating pressures A series regulators are suitable for a variety of applications ...
Pressure: 0.5 bar - 220 bar
Orifice diameter: 0.75 in - 1 in
... Pneumatic Loaded Pressure Reducing Regulators developed by Tartarini. They use high pressure gas in compression with cylinders in applications of regulating ...
Tartarini
... and multi-stage regulators suited to most fuel gas welding, cutting and heating processes and compressed gases. Premium Models At the high end of the spectrum, our premium range represents the gold ...
... complies with safety regulations and standards. High-quality and high-capacity CO2 pressure regulator. Max. 200 bar primary pressure. Equipped with manometer for gas ...
Migatronic Welding Equipment LTD.
Pressure: 10, 16, 25, 40 bar
Flow: 1 m³/h - 200 m³/h
Orifice diameter: 15 mm - 150 mm
Regulators are used to control preset pressure in process installations connected to regulator valve outlet. They are used in district heating systems, industrial ...
Flow: 4 l/h - 200 l/h
Gas flowmeters are gas flow indicators applied in a gas chlorination system to regulate the flow. General Differential pressure regulators are designed ...
Pressure: 50, 10, 15, 16 bar
Flow: 50, 100 m³/h
Temperature: -20 °C - 60 °C
Application: For high purity gases and high pressure applications requiring high flow and precise outlet pressure, such as for laser applications and nuclear research. Key Advantages: Outstanding ...
Rotarex
Pressure: 413.7 bar
Temperature: -40 °C - 149 °C
The Model GR™ Genie® Pressure Regulator is a single stage pressure regulator designed specifically for use in gas analyzer sample conditioning systems. Its stainless ...
SOCLEMA
Pressure: 20 mbar - 4,000 mbar
Orifice diameter: 2, 1 in
Temperature: -20 °C - 60 °C
The Monobloc PRS station have been designed to attend all new necessities of Hydrogen Pressures Control with its whole security associated following EN12186 in only one and small unit ...
Pressure: 10 bar
... non-burning gases (up to 5.0 purity) Inlet pressure 10 bar max. Outlet pressure 0.2-4 bar Inlet / outlet connections: Female threads ISO 228 G1/4" (other connections available) Integrated outlet pressure ...
Carlos Arboles S.A.
Pressure: 0 bar - 200 bar
Orifice diameter: 6.3, 0.07 mm
A single stage regulator for nitrogen reducing the inlet pressure from 200bar to any pressure between 0 and 200 bar. One of the main application used onboard is for pressure ...
Wilhelmsen
Pressure: 200 bar
Pressure Regulator for Bottled Gas DIN EN ISO 2503 Single-Stage Pressure Regulator for Bottled Gas serve to regulate compressed, liquefied and under ...
Pressure: 350, 220 bar
... available on request. Outlet pressure up to 15 bar (218 psi) is controlled by a diaphragm; greater outlet pressures are controlled by a piston. The main valve is balanced for outlet pressure ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining