Primary current: 630 A - 1,600 A
VAC: 415, 220 V
... compact size. MasterPact NT circuit breakers are equipped with MicroLogic control units that offer built-in power and energy metering in addition to basic or advanced protection functions. ...
Schneider Electric
Primary current: 800 A - 6,300 A
VAC: 415, 220, 1,150 V
... 6300 A in two different sizes. The worldwide benchmark for high current circuit breakers MasterPact NW circuit breakers are equipped ...
Schneider Electric
Primary current: 3.3 A - 108 A
VAC: 250 V
Rating: 0.5 A - 20 A
... thermal-magnetic circuit breakers that enable reliable protection of industrial equipment control circuits, such as power supplies, electronic systems protection, PLC, ...
Schneider Electric
Primary current: 1 A - 63 A
VAC: 400, 230 V
VDC: 125, 80 V
Hydraulic Magnetic Circuit Breaker-BSB7-C63-1P BSB7 series hydraulic circuit breakers are suitable for distribution lines with rated AC ...
Primary current: 80 A
VAC: 12 V - 253 V
VDC: 12 V - 52 V
... buildings. Miniature circuit-breakers utilise both the magnetic and heat effect of the electrical current. If the current jumps to a value that is too ...
Primary current: 110 A - 400 A
VDC: 80 V
DD Frame - Higher Ratings Bridged Poles 80 Vdc Plug-in Terminals Description: Ratings: Available in 240 A & 250 A Number of Poles: Triple Pole Bridged: • 240 A to 250 A Curves: • AS (Long Delay) • BS (Medium Delay) • ...
CBI-electric: low voltage
Primary current: 240, 250 A
VDC: 80 V
DD Frame - Higher Ratings Bridged Poles 80 Vdc Rear Studs Terminals Description: Number of Poles: Three Pole Bridged Curves: • AS (Long Delay) • BS (Medium Delay) • CS (Short Delay) Mounting Options: Metric or Imperial ...
CBI-electric: low voltage
Primary current: 110 A - 400 A
VDC: 80 V
DD Frame - Higher Ratings Bridged Poles 80 Vdc Plug-in Terminals Description: Number of Poles: Four Pole Bridged: Curves: • AS (Long Delay) • BS (Medium Delay) • CS (Short Delay) Mounting Options: Metric or Imperial ...
CBI-electric: low voltage
Primary current: 110 A - 400 A
VDC: 80 V
DD Frame - Higher Ratings Bridged Poles 80 Vdc Rear Studs Terminals Description: Number of Poles: Four Pole Bridged: Curves: • AS (Long Delay) • BS (Medium Delay) • CS (Short Delay) Mounting Options: Metric or Imperial ...
CBI-electric: low voltage
Primary current: 110 A - 400 A
VDC: 80 V
DD Frame - Higher Ratings Bridged Poles 80 Vdc Plug-in Terminals Number of Poles: Five Pole Bridged: Curves: • AS (Long Delay) • BS (Medium Delay) • CS (Short Delay) Mounting Options: Metric or Imperial Mounting Terminations: ...
CBI-electric: low voltage
Primary current: 110 A - 400 A
VDC: 80 V
DD Frame - Higher Ratings Bridged Poles 80 Vdc Rear Studs Terminals Description: Number of Poles: Five Pole Bridged: Curves: • AS (Long Delay) • BS (Medium Delay) • CS (Short Delay) Mounting Options: Metric or Imperial ...
CBI-electric: low voltage
Primary current: 125, 300, 250 A
VDC: 60 V
DD Frame - Higher Ratings 60 Vdc Rear Studs Description: Number of Poles: Single Pole Curves: • AS (Long Delay) • BS (Medium Delay) • CS (Short Delay) Mounting Option: Metric Mounting Terminations: M6 Rear Studs ...
CBI-electric: low voltage
Primary current: 300, 250, 125 A
VDC: 60 V
DD Frame - Higher Ratings 60 Vdc Rear Studs Description: Number of Poles: Double Pole Bridged: Curves: • AS (Long Delay) • BS (Medium Delay) • CS (Short Delay) Mounting Option: Metric Mounting Terminations: M6 Rear ...
CBI-electric: low voltage
Primary current: 300, 250, 125 A
VDC: 60 V
DD Frame - Higher Ratings 60 Vdc Rear Studs Number of Poles: Triple Pole Bridged: Curves: • AS (Long Delay) • BS (Medium Delay) • CS (Short Delay) Mounting Option: Metric Mounting Terminations: M6 Rear Studs Approvals: • ...
CBI-electric: low voltage
Primary current: 1,250, 4,000, 3,150, 2,000, 2,500 A
VAC: 7.2 V - 40.5 V
... also for high-voltage applications. The powerful 3AH3 vacuum circuit breakers were the first 63- and 72-kA vacuum circuit breakers on the market tested ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining