Voltage: 48 V
Primary current: 13 A
• DC continuity for remote powering • RF peak power not limited by gas discharge tube • Excellent low PIM performance; Ideal for multicarrier systems • Availability for application bands between 380 MHz and 18 GHz • Gas discharge ...
Voltage: 275, 320 V
Primary current: 20,000, 40,000 A
-1 MOV+1 GDT combined in one cartridge. -surgearresters consisting of a base part and1 MOV+GDT plug-in protection modules. -High energy MOV and GDT hybrid unit inside. -Low residual voltage and quick ...
Voltage: 110 V - 400 V
Primary current: 40,000, 80,000 A
Open circuit voltage: 1.5, 1.7, 2 kV
- Class I+II / B+C, Type 1+2 surge arresters. - 3P+N, 3 phases - Imax 80kA, In 40kA, Iimp 12kA. - High energy MOV and GDT hybrid unit inside. - Low residual voltage and quick response. - ...
Voltage: 110 V - 400 V
Primary current: 40,000, 80,000 A
- Class I+II surge arresters. - 4P, 3 phases - Imax 80kA, In 40kA, Iimp 12kA. - High energy MOV and GDT hybrid unit inside. - Low residual voltage and quick response. - Reliable ...
Voltage: 7, 16, 32, 55 V
Primary current: 700 mA
Introducing the MTL SD Modular (SDM) range of data & signal surge protection providing the ultimate surge protection solution for process automation, instrumentation and communications networks. The ...
Voltage: 240 V - 300 V
Primary current: 25,000 A - 65,000 A
• Leakage free hybrid topology • High discharge capacity due to unique design impulse discharge current of 25 kA • Energy coordinated with other ProTec families without additional cable length • State-of-the-art thermal ...
Raycap
Voltage: 240 V
Primary current: 20,000 A
... contact (RC) features a three-pole remote signaling terminal to remotely monitor the operating state of the device. The surge arrester is designed to fully comply with the latest requirements of the German ...
Raycap
Voltage: 240 V - 300 V
Primary current: 20,000 A - 65,000 A
• Leakage free hybrid topology • Energy coordinated with other ProTec families without additional cable length • State-of-the-art thermal disconnector • Backup fuse up to 315 A gG • Short circuit current rating up ...
Raycap
Voltage: 240 V
Primary current: 20,000 A
... • All modules including N-PE, with operating state green-red • Optional remote contact signaling (RC) The ProTec T2H surge protection device provides high durability due to its leakage-free performance ensured by ...
Raycap
Voltage: 900 V
• Maximum Continuous Operating DC voltage 1000 V • High Surge Discharge Current (ITotal) 12.5 kA (10/350) • Short circuit current rating up to 50 kA • Leakage Free hybrid topology • High Energy MOV ...
Raycap
Voltage: 400 V
Primary current: 25,000 A
... operating state fault indication green-red • Optional remote contact signaling SafeBloc B offers basic protection as a Type 1 surge protective device that comes with a Maximum Continuous Operating Voltage (Uc) range ...
Raycap
Voltage: 900 V
Primary current: 20,000 A
• Maximum Continuous Operating DC voltage 1000 V • High Surge Discharge Current (ITotal) 65 kA (8/20) • High TOV immunity • Vibration and shock-resistant • UL Type 4CA certified • Optional remote contact (RC) signaling • ...
Raycap
Voltage: 120 V - 275 V
Primary current: 20,000 A
... operating state fault indication green-red • Optional remote contact signaling SafeBloc B offers basic protection as a Type 1 surge protective device that comes with a Maximum Continuous Operating Voltage (Uc) range ...
Raycap
Voltage: 400 V
Primary current: 60,000 A
... indoor or outdoor installation on a roof or tower top.Configurable cable ports are designed to accommodate varying diameters of hybrid (combined power and fiber optic) or standard cables with diameters up to 1-5/8″ (41.27mm) ...
Raycap
Primary current: 60,000 A
... or outdoor installation on a roof or tower top. Configurable cable ports are designed to accommodate varying diameters of hybrid (combined power and fiber optic) or standard with diameters up to 1.625″ [41.27mm] depending ...
Raycap
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining