- Electricity - Electronics >
- Cable, Connector, Enclosure >
- Insulated electrical cable
Insulated electrical cables
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Nominal voltage: 1,500, 500, 350 V
Temperature: -30 °C - 70 °C
Cross-section: 0.14 mm² - 1.5 mm²
PVC data cable LiYY with reference to DIN 47100 Marking for LiYY 03053225: SAB BRÖCKSKES · D-VIERSEN · LIYY 32x0,25mm²CE LiYY Cable - The PVC/PVC data cable is a flexible data cable ...
Temperature: -40 °C - 70 °C
Cross-section: 0.75, 0.5, 1.5, 1, 0.22 mm²
In this chapter you will find compensating & thermocouple extension wires with PVC insulation. They are appropriate for temperatures up to + 70°C.
Temperature: -10 °C - 80 °C
Cross-section: 0.08 mm²
Length: 1, 100, 500 m
Data Transfer Cable, highly flexible, 0,08mm², shielded pairs individually insulated, outer shielding, 2 to 12-paired, conductor colors white and brown resp., CU-bare spiral shielding and PVC insulation ...
Metrofunk Kabel-Union
Temperature: -10 °C - 80 °C
Cross-section: 0.22 mm²
Length: 1, 500, 100 mm
Control Cable with 7-stranded core 0,22mm² (AWG 24), twisted pairs, outer shielding, halogen free, for robust application, with PUR-jacket, 1 to 4 pairs; conductorpairs are individuallly shielded and insulated
Metrofunk Kabel-Union
Nominal voltage: 350 V
Cross-section: 0.08 mm²
Length: 100, 500, 1 m
shielded PE-insulated cable, especially for microphones, sound heads, dictaphones number of cores: 1
Metrofunk Kabel-Union
Nominal voltage: 220 kV
Temperature: 90 °C
Cross-section: 240 mm² - 2,500 mm²
... 5S ), the conductor temperature: not exceed 250 ℃ 4、0℃,≥18D (D) The minimum temperature of cable laying: 0℃ The minimum bending radius≥ 18D (D is the cable outer diameter )
Shanghai Morn Electric Equipment Company
Nominal voltage: 300 V - 500 V
Temperature: -60 °C - 350 °C
Multi-conductor cable, galvanized steel armouring, mineral fiber insulated conductors, nickel core - Applications : Heating elements Heating appliances Heavy industry - Approvals : Veritas Industrie ...
... approximate values. Tensile force only valid when cable sheath and cable core involved. The bending radius one-off is for professionally installed cables, unique molding over a stencil ...
Nominal voltage: 300, 500 V
Temperature: -60 °C - 200 °C
Cross-section: 0.35 mm² - 1 mm²
High temperature cable KFPG Applications: Used at Rated coltage 300V/500V or below with various movable electric machines, stel plant. aviation, power plant petrochemical insustry and outdoor lighting of high temperature ...
Nominal voltage: 600 V
Temperature: 150, 260 °C
ETFE/FEP/PFA Insulated Cable & Wire Conductor: AWG 18(7/26) TPC Insulation: ETFE/FEP/PFA (OD=0.098") Jacket: Polypropylene/PFA (OD=0.192") Finished OD: 0.192"+/-0.002" Rating: ...
Signal cable connect the sensor and the preamplifier and it can shield the sensor from electromagnetic interference. Features: Solid polytetrafluoroethylene insulated coaxial cables
Coaxial cable is used for transmitting the AE signals, and as the cable connecting the preamplifier and the acquisition instrument, which has wideband of frequency and excellent noise suppression characteristics. Features: Radio ...
Nominal voltage: 0 V - 1,000 V
Temperature: 70 °C - 1,200 °C
Cross-section: 0.1 mm² - 2.5 mm²
Instrumentation Signal Cables minimize noise and signal interference, delivering clean signals in harsh environments and general manufacturing operations. These cables are designed for use in communication ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining