- Electricity - Electronics >
- Switch and Relay >
- Intrinsically safe electrical safety barrier
Intrinsically safe electrical safety barriers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Intrinsic Safety Lamp Barriers are essential components of an intrinsically safe application. These devices are to limit the voltage and current to prevent ignition in ...
IDEC
These intrinsically safe barriers allow to repeat in a safe area a potentiometric signal located in an hazardous area. These devices provide a complete galvanic isolation ...
VAL.CO srl
Intrinsic safety barriers for On-Off level controls Relay output The intrinsic safety barriers for level sensors MULTIPOINT I (OnOff) allow to repeat, in a safe ...
VAL.CO srl
The intrinsic safety barriers for level sensors MULTIPOINT I (OnOff) allow to repeat, in a safe area, a NO or NC contact installed in an hazardous area . Certificate N. TUV 14 ATEX ...
VAL.CO srl
... 2088 X ATEX gas explosion protection - II 3 (1) G Ex ec [ia Ga] IIC T4 Gc ATEX dust certificate - PTB 01 ATEX 2088 X ATEX dust explosion protection ...
R. STAHL AG
... Series MTL7706/7787 Zener Barriers are an intrinsically safe shunt-diode barrier that can be used to communicate with and provide isolations for certain Dwyer ® transmitters ...
Input contacts can be used in any explosive gas and Zone 0/Class I Div. 1 areas.Explosion protection Relay Barrier: [Exia] II C Switch (EB9Z-A): Exia II CT6 Switch (EB9Z-A1): Exia II BT6 IEC60079 ...
... loop disconnect by simply unplugging the terminals from the side of the module. Wire entry is also angled to assist wiring within limited space enclosures. MTL7700 barriers clamp simply and securely onto ...
... monitoring system. In safety applications (SIL loops), the 9106BxBx can be used as a splitter with the following output configuration: • When using 9106BxBx in a SIL2 safety function, channel ...
PR ELECTRONICS
The DAT 5030 IS/A device is a galvanic isolated Intrinsically Safety Barrier, defined as “Associated Apparatus” The input can measure 0-20 mA or 4-20 mA current loops, both active or ...
DATEXEL SRL
• Barrier unit for addressable intrinsically safe fire detectors in hazardous areas • Barrier unit connects directly on the loop and is mounted outside Ex area • Up ...
Intrinsic safety barriers from Pepperl+Fuchs limit the energy that is supplied to a circuit and protect hazardous areas from excess energy. By limiting energy to a safe level, intrinsically ...
In addition to their explosion protection function, isolated barriers offer galvanic isolation to protect measurement and control circuits from signal distortion and dangerous surges. These interface ...
The H-System is a termination board based interface solution with stationary wiring. Modules can be mounted tool-free and replaced during operation without wiring effort. Termination Boards The H-System is a termination board based ...
... channel Complete galvanic isolation Input reverse-polarity protected Protection class IP67 Connection with M12 male connectors ATEX, CFMUS, IECEx ...
Safety barrier for intrinsically safe measurement current transmission in zone 1 for 4 ... 20 mA display instruments Application area The safety ...
... provides for the safe operation of an intrinsically safe electrical apparatus installed in a hazardous gas or dust environment classified as Zone 0, 1, 2, 20, 21, or ...
2-12 Channel Switch Module and Intrinsically Safe Barriers, Stainless Steel Enclosure
Intrinsic safety barriers for plants in areas at risk of explosion certificate:construction intrinsically safe approvalDMT 01 ATEX E 042 X -II (1) G ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.