- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- IP68 flow meter
IP68 flow meters
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Process temperature: -40 °C - 150 °C
... AquaTrans AT600 is a liquid clamp-on flow meter designed to be accurate, durable and cost-effective. Rugged and reliable, this meter will remain fixed to your pipe for years to come. Applications The ...
Process temperature: -40 °C - 150 °C
The TransPort PT900 portable ultrasonic liquid flow meter is Panametrics’ newest portable clamp-on flow meter. It easily attaches to the piping fixture to measure flow ...
Process temperature: -5 °C - 90 °C
Process pressure: 0.1 bar - 5 bar
The OPTIFLUX 2000 is an electromagnetic flowmeter (EMF) for water and wastewater applications which has many drinking water approvals. •Meets drinking water standards •Wear and maintenance free •Wide dynamic measuring range
Process temperature: 0 °C - 30 °C
Process pressure: 16 bar
... tamper-proof, weatherproof, and UV-resistant casing, the Cubic ultrasonic water meter is especially robust, durable, and suitable for challenging climates. Unlike mechanical meters, the ultrasonic technology ...
Process temperature: 0 °C - 30 °C
Process pressure: 16 bar
... tamper-proof, weatherproof, and UV-resistant casing, the Cubic ultrasonic water meter is especially robust, durable, and suitable for challenging climates. Unlike mechanical meters, the ultrasonic technology ...
... PROFINET The TIDALFLUX 2300 is an electromagnetic flowmeter (EMF) with a patented, capacitive level measurement for use in partially filled pipes (up to DN1600 / 64”). The meter is the ideal solution ...
KROHNE Messtechnik GmbH
... OIML R49 up to DN600 / 24", no inlet/outlet runs needed • Burial installation possible (IP68) The WATERFLUX 3070 is a battery powered electromagnetic water meter for use in water ...
KROHNE Messtechnik GmbH
Process temperature: -40 °C - 180 °C
Liquid flow meter OPTIFLUX 4000 Electromagnetic flowmeter for advanced process and custody transfer (CT) applications •High accuracy (±0.2%), certified for custody transfer •For low ...
KROHNE Messtechnik GmbH
Process temperature: -25 °C - 130 °C
Process pressure: 10, 40 bar
ProcessMaster FEP610 offers robust, cost effective flow measurement with the industry´s widest range of liners, electrodes and sizes to meet the needs of all industrial standard applications. The ProcessMaster´s concept ...
Process temperature: -6 °C - 70 °C
Process pressure: 25, 40 bar
... increasing legislative demands for accurate flow metering. Its wide measuring range ensures peak daytime flows are accurately recorded and its exceptional low flow performance aids network ...
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 20 bar
... rod. AquaProbe finds application in existing water distribution systems where provision for flow metering was not originally made and where a full bore flow meter would be uneconomic. ...
Precision: 0.25, 0.15 %
Rosemount 8705 Flanged Magnetic Flow Meter Sensors provide long-lasting, reliable performance in even the most challenging applications. An all-welded construction provides a hermetic seal that protects ...
Process temperature: 0 °C - 50 °C
Process pressure: 0 Pa - 1,586,000 Pa
Precision: 2, 5 %
• Economical Ultrasonic Flow Meter for Water Service • DN 32 to 200 (2 to 8") Flanges • Battery Powered • Displays Flow Rate and Total • Extended Low Flow ...
Process temperature: -26 °C - 121 °C
Process pressure: 0 bar - 14 bar
Precision: 1 %
The ISM 5.0 Electromagnetic Flow Meter is an accurate, low-cost insertion mag flow meter alternative to full-bore mag flow meters. Measure ...
The SeFlow 400 is Sewerin’s single channel portable flowmeter for applications in the municipal water and wastewater sector offering long term stable and precise bidirectional flow measurements in remote ...
Volumetric flow rate: 4 l/h - 200,000 l/h
Process temperature: -50 °C - 200 °C
Precision: 5, 2 %
New-Flow offers a large variety of products for measurement and control of temperature, pressure, flow, level, and valve.
Golden Mountain Enterprise
Volumetric flow rate: 0.4 l/h - 4,000 l/h
Process temperature: -40 °C - 180 °C
Precision: 2, 1.6 %
New-Flow offers a large variety of products for measurement and control of temperature, pressure, flow, level, and valve. Case Material: SS316
Golden Mountain Enterprise
Volumetric flow rate: 20 l/h - 4,200 l/h
Process temperature: 0 °C - 70 °C
Precision: 2 %
New-Flow offers a large variety of products for measurement and control of temperature, pressure, flow, level, and valve. Power Supply: 3.8V to 30VDC Output: Sink(NPN) and 4~20mA Body Material: Polypropylene, ...
Golden Mountain Enterprise
... ultrasonic technology for mobile and highly accurate flow measurements Special features: ■ Very high measurement accuracy (also bidirectional) ■ Accurate even at extremely low flow rates (e.g. minimum ...
Volumetric flow rate: 1.6 m³/h - 3,125 m³/h
Process temperature: -40 °C - 70 °C
Process pressure: 1 bar - 10 bar
... reasonably priced, most accurate flow meter tailored for your applications. A flowmeter with base functionality, short delivery and a simple and clearly understandable documentation. EPD ...
Process temperature: -30 °C - 80 °C
... cycle operation for self-sufficient systems Flow metering at the highest technical level The NivuFlow 750 flow meter is the successor to the well-known OCM Pro CF. Compact dimensions ...
NIVUS GmbH
Process temperature: -20 °C - 70 °C
... as in low flow level circumstances -IoT-ready with global 4G connectivity for highest availability and digital services Hybrid Flow Measurement NivuFlow 7550 is a hybrid measurement system ...
NIVUS GmbH
Process temperature: -20 °C - 70 °C
... ambient conditions. The large graphic display permits quick and easy commissioning of the flow meter system. Due to the modular construction of our radar flow meter ...
NIVUS GmbH
Process pressure: 0.6 mbar - 4 mbar
Precision: 0.2 %
... supply IP65 protection class Robust housing Excellent flow mesurement accuracy, can measure duplex flow, electromagnetic debimeter with 4-20mA and other outputs General Features Excellent ...
Precision: 0.25, 0.4 %
Repeatibility: 0.5 %
... various sensor parameters, anticipating possible problems. The battery converter with integrated modem MV255, flow meters, energy meters, contact our specialists.
Process temperature: 0 °C - 100 °C
Process pressure: 25 bar
Precision: 2 %
... sensor. The compact battery-powered insertion flow meter CS3820, flow meters, energy meters, ultrasonic flowmeters, and industrial automation systems ...
Volumetric flow rate: 40 m³/h - 500 m³/h
Process temperature: -20 °C - 70 °C
Process pressure: 16 bar
... a complete range of flow meters ISOFLUX, intended for flow measurements of conductive, non-conductive liquids, the range includes the following versions: Description The ultrasonic ...
Volumetric flow rate: 0.1 m³/h - 40,715 m³/h
Process temperature: -20 °C - 150 °C
Process pressure: 0 bar - 40 bar
... will induce a voltage proportional to the mean flow velocity rate and hence the volumetric flow. A magnetic inductive flowmeter consist of an isolated lined tube, through which a conductive ...
Process temperature: 0 °F - 302 °F
Process pressure: 0 psi - 232 psi
... M5000 is a battery-powered electromagnetic flow meter with a very high accuracy even at very low flows. The excellent repeatability as well as the above-average battery life makes this ...
Process temperature: -20 °C - 70 °C
This flowmeter measures accurate flow rate with a precise sensor and provides various weir and plume measurement formulas, making it easy to use according to the user's environment. Main features Open ...
Volumetric flow rate: 1.5 m³/h - 9,048 m³/h
Process temperature: -40 °C - 85 °C
Precision: 0.5, 0.2 %
... able to process signals from fluids with flow rates of up to 10m / s in both directions (bidirectional meter). Reverse Flow - Allows measure and totalization of reverse flow Output ...
SGM LEKTRA
Volumetric flow rate: 0.1 m³/h - 18,000 m³/h
Process temperature: -40 °C - 100 °C
Precision: 0.5 %
... passive 4÷20mA, Pulse: open collector Reverse Flow - Instant measure and totalization of reverse flow Flow Cutoff - Adjustable in units of flow measurement. ...
SGM LEKTRA
Volumetric flow rate: 0.1 m³/h - 110,000 m³/h
Process temperature: -40 °C - 150 °C
Precision: 0.5 %
... ; 20 ÷ 36 Vac/Vdc; 11 ÷ 13Vdc Reverse Flow - Instant measure and totalization of reverse flow Flow Cutoff - Adjustable. Below selected value, instantaneous flow ...
SGM LEKTRA
Volumetric flow rate: 0.1 m³/h - 381,703.5 m³/h
Process temperature: -10 °C - 60 °C
Process pressure: 0 bar - 250 bar
Electromagnetic Flow meter does not have any moving parts, ideal for wastewater applications or any dirty liquids which is conductive or water based, or for applications where low-pressure drop and low ...
Holykell
Process temperature: -30 °C - 160 °C
Precision: 1 %
Repeatibility: 0.5, 0.2 %
The Economic type Clamp-on Ultrasonic Water Flowmeter can be applied to a wide range of pipe flow measurements. Applicable liquids include pure liquids as well as liquid with small quantity of tiny particles. ...
Holykell
Process temperature: -30 °C - 80 °C
Precision: 2, 1 %
... solution for monitoring the flow or velocity of open channels, agricultural irrigation or groundwater. the best solution. Application : ● Open channel flow rate or flow monitoring ...
Holykell
Process temperature: -30 °C - 160 °C
Precision: 1 %
... provides over 12 hours of continuous operation Measurement: non-invasive clamp-on transducer, no pressure drop, no pipe disturbance Menu support in multiple languages: English, Italian and other languages can be customized Large ...
ASIT ITALIA
Process temperature: -30 °C - 160 °C
Precision: 1 %
PORTABLE ULTRASONIC FLOW METER Applications: flow measurement of liquids non-invasive version, transit time technology Working Range: ±32m/s Size: installation in pipes from DN20 to ...
ASIT ITALIA
Process temperature: -30 °C - 160 °C
Process pressure: 2.5 MPa
Precision: 1 %
The AI.FFSONIC.INLINE flow measurement system is composed of a digital converter and two ultrasonic transducers with in-line insertion on the pipes. The transit time of a fluid, inside a cylindrical section tube, is the ...
ASIT ITALIA
Volumetric flow rate: 0.1 m³/h - 9.5 m³/h
Process temperature: -20 °C - 130 °C
Process pressure: 0 bar - 64 bar
The RIF100 is an electromagnetic flow meter that utilizes Faraday's principle to measure the velocity of the liquid and convert it into a signal proportional to the flow. Among its ...
Riels Instruments
Process temperature: -20 °C - 130 °C
Process pressure: 64 bar
Precision: 0.5 %
... the flow reaches the cut off limit (low flow cut) set. Reverse flow alarm: intervenes when the flow measurement reverses direction. System alarm: intervenes in case ...
Riels Instruments
Process temperature: -20 °C - 130 °C
Process pressure: 64 bar
Precision: 0.5 %
The RIF110 is an electromagnetic flow meter that utilizes Faraday's principle to measure the velocity of the liquid and convert it into a signal proportional to the flow. Among its ...
Riels Instruments
Process pressure: 1.6, 2.5, 4 MPa
Precision: 5 %
Electromagnetic flowmeter type PEM-500 is applicable to the measurement of flow of the liquids with minimum conductivity of 5ěS/cm. Device measures flow and volume of liquids in both directions ...
Process temperature: 0 °C - 250 °C
Precision: 2 %
The DOPPLER flowmeters are designed to measure the volumetric flow in closed and full pipes. It consists of two sensors an emitter and an ultrasonic receiver. The emitted waves are transmitted by the ...
Sensotec Instruments
Precision: 0.2 %
... ADVANTAGES OF ELECTROMAGNETIC FLOWMETERS OVER OTHER FLOWMETERS · There are no mechanical parts that prevent the flow and reduce the pressure. · Measurement scale; It is ...
ENELSAN ENDUSTRIYEL ELEKTRONIK SANAYII A.S.
... precise flow measurements can be made without the need for costly modifications on the existing line. There are no mechanical parts that prevent the flow or reduce the pressure. measurement scale; It ...
ENELSAN ENDUSTRIYEL ELEKTRONIK SANAYII A.S.
Mass flow rate: 2.2 kg/h - 243,954.9 kg/h
Volumetric flow rate: 0.5 m³/h - 14,000 m³/h
Process pressure: 1 bar - 25 bar
... rich self-checking information make easy maintenance and debugging * Independent password setup, the parameters setup, total flow reset and calibration can be set with different- level passwords, it is convenient for ...
ENELSAN ENDUSTRIYEL ELEKTRONIK SANAYII A.S.
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining