Level range: 0.4 m - 120 m
Process pressure: -1 bar - 40 bar
Process temperature: -55 °C - 1,200 °C
RADAR SENSOR The multifunctional 80 GHz radar sensor, available in two-wire and four-wire technology, provides continuous, non-contact level measurement for bulk solids and works very ...
UWT GmbH
Level range: 250 mm - 120,000 mm
Process pressure: -1 bar - 160 bar
Process temperature: -196 °C - 450 °C
RADAR SENSOR The multifunctional 80 GHz radar sensor, available in two-wire and four-wire technology, provides continuous, non-contact level measurement for liquids and works very precisely, ...
UWT GmbH
Level range: 300 mm - 25,000 mm
Process pressure: -1 bar - 35 bar
Process temperature: -40 °C - 400 °C
Application area The capacitive level sensor NivoCapa® 8100 is a simple and cost-effective solution for level measurement of liquids or oils. Interface measurement ...
UWT GmbH
Level range: 12 in - 300 in
Process temperature: -40 °F - 221 °F
... Accuracy ±1mm – Intrinsically Safe – Sanitary Finish Ra 25 μin (0.64 μm) – Electropolished Finish Ra 15 μin (0.38 μm) Applications: – Process Control – Batching – Bioreactor Markets: – ...
Level range: 10 m
Process pressure: 8 bar
Process temperature: -40 °C - 80 °C
... installation and maintenance-free operation * Remote sensor parameter setting and level monitoring via connection to the IT system Trouble-free monitoring of large tanks With the ...
Level range: 11 mm - 253 mm
Process temperature: -40 °C - 100 °C
... fixed setting Differentiation of media by parameterisation of the switching outputs Specially for the use in hygienic applications
Level range: 153, 253, 11 mm
Process pressure: 0 bar - 40 bar
Process temperature: -20 °C - 85 °C
For the reliable level control in tanks and containers Hygienic design for the requirements of the food and beverage industry Use in liquid and viscous media ...
Level range: 0.3, 4, 6 m
Process pressure: 0 Pa - 1,000,000 Pa
Process temperature: -40 °C - 250 °C
Food and beverage industry Pharmaceutical industry Biotechnology Level measurement in fermenters Special features Fully welded and dead space free Operating ...
Level range: 0 m - 120 m
Process pressure: -1 bar - 160 bar
Process temperature: -196 °C - 450 °C
VEGAPULS 6X is a radar sensor for continuous level measurement of liquids and bulk solids. The small process fittings offer particular advantages for liquids in small tanks or tight mounting spaces. ...
Level range: 0 m - 32 m
Process pressure: 0 bar - 16 bar
Process temperature: -40 °C - 150 °C
... point where this item comes in handy. The radar level sensor comes in a stainless steel construction, which allows easy cleaning of the instrument. Next, the sensor is also ideal ...
Level range: 0 m - 15 m
Process pressure: 0 bar - 3 bar
Process temperature: -40 °C - 80 °C
... radar sensor for continuous level measurement Application area Axial cable outlet, measuring range up to 15 m, accuracy ±2 mm, 4 ... 20 mA, HART, SDI-12 or Modbus output, Ex-approval VEGAPULS ...
Level range: 0 m - 35 m
Process pressure: 0 bar - 16 bar
Process temperature: -196 °C - 200 °C
Radar sensor for continuous level measurement of liquids For aggressive liquids or under hygienic requirements The front-flush mounting of the encapsulated antenna system ensures ...
Level range: 0 m - 32 m
Process pressure: 0 bar - 16 bar
Process temperature: -40 °C - 150 °C
TDR sensor for continuous level and interface measurement of liquids For aggressive media or extremely high hygienic requirements Application area PFA coated or ...
Level range: 3 m - 10 m
Process temperature: -40 °C - 80 °C
The IMP range of level sensors feature a combined transducer and controller in one self-contained unit. All IMP units from Pulsar Measurement are non-contacting, accurate, and reliable level ...
Level range: 40 mm - 1,200 mm
Process temperature: -40 °C - 55 °C
Continuous and precise measurement of fill levels in brake sand boxes of locomotives and tramways • Level measurement by optical ToF measuring • No need for regular manual checks of the sandboxes by ...
Level range: 200 mm - 1,000 mm
Process temperature: 0 °C - 70 °C
Description Level and temperature monitoring with just one unit •Temperature range 0...70°C •Probe rod max. 1000 mm lenght •Accuracy +/- 1 °C •Combinable with different amplifiers APPLICATION: ...
Process temperature: 0 °C - 230 °C
... be output in three different versions 0...20mA, 4...20mA or 0...10V - Optical level representation by means of LED-bar indicator APPLICATION: PLANTS & MACHINES | FOOD & BEVERAGES Specifications: Supply ...
Level range: 1 m - 250 m
Process pressure: 0.1 bar - 25 bar
Process temperature: -10 °C - 70 °C
... areas of application: energy industry, environmental industry The stainless steel probe CPA-P-307 is designed for continuous level measurement in water and clean or waste fluids. Basic ...
SIMEX Sp. z o.o.
Level range: 1 m - 100 m
Process pressure: 0.1 bar - 10 bar
Process temperature: -20 °C - 80 °C
... areas of application: energy industry, environmental industry The separable plastic probe CPA-P-808 is designed for level measurement of water, waste water as well as fuels and oils. ...
SIMEX Sp. z o.o.
Level range: 1 m - 250 m
Process pressure: 0.1 bar - 25 bar
Process temperature: -10 °C - 70 °C
... small thermal effect excellent linearity areas of application: energy industry, environmental industry The slimline probe CPA-P-305 with silicon stainless steel sensor is designed ...
SIMEX Sp. z o.o.
Process pressure: -1 bar - 25 bar
Process temperature: -40 °C - 239 °C
... constrained, and need process control. This compact sensor is great for level measurement and pressure detection for liquids or solids in ordinary environments and in sanitary and hygienic ...
Level range: 1 m - 35 m
Process pressure: 10,000 Pa - 3,500,000 Pa
Process temperature: -40 °C - 300 °C
Hygienic pressure transmitter, designed for food and pharmaceutical industry, is suitable for CIP/SIP cleaning and sterilization. Smart compact design, the wetted parts is made of high quality stainless ...
Sanitary pressure transmitter, designed for food and pharmaceutical industry, is suitable for CIP/SIP cleaning and sterilization.Smart compact design, the welded process diaphragm medium parts is made ...
Process pressure: max 69.0 bar
Process temperature: -40 °C - 125 °C
Drexelbrook TLS, Total Tank Level System, provides unparalleled accuracy for tank level and temperature measurements. The versatillity of the many probes makes TLS the ideal solution for most tanks ...
Level range: max 21.3 m
Process pressure: 1,000 psi
Process temperature: -40 °C - 100 °C
... reliability as sensors that consume more power which results in savings. The Series basically consists of of models of level sensors. The 7250V liquid level sensor ...
Process pressure: 1,000 psi
7330 Pro-Stik II Level Sensor have been proven in demanding applications such as underground leak detection and inventory management. The Drexelbrook 7330 Pro-Stik II Series are intrinsically ...
Level range: 0.1 m - 5 m
Process temperature: -40 °C - 60 °C
The maxSHIFT60 Compact cloud level radar sensors enable the installation of a high-end radar level measurement system in a minute. Without the use of any power source or local network ...
Level range: 400 mm - 22,000 mm
Process pressure: -1 bar - 120 bar
Process temperature: -20 °C - 450 °C
TORRIX XTS: The ALL-ROUNDER for level measurement TORRIX XTS is the most advanced probe in the TORRIX family and offers in addition to pure level measurement of the product and interface layer, it ...
Level range: 0.3 mm - 22,000 mm
Process pressure: -1 bar - 120 bar
Process temperature: -20 °C - 450 °C
... complements the TORRIX program with a compact magnetostrictive level sensor with LED display. The LED display shows the fill level directly on the tank. Advantages + Highly accurate ...
Level range: 0 m - 100 m
Process temperature: -30 °C - 65 °C
SUP-P260-M2 Slurry level meter are completely sealed for submersion in liquid, can be used to measure water level, well depth, groundwater level and so on, common accuracy is 0.5%FS,with ...
Level range: 20 m
Process temperature: -60 °C - 150 °C
... : complexsanitary antenna, small beam angle, strong wave focusing, high accuracy. Application: food processing, pharmacy, and other requested sanitary tank level measurement.
... correct assessment of the bin's fill level in many common situations. While traditional products calculate the fill level on the basis of the waste closest to the sensor, RML is able ...
Process pressure: 10 bar
Process temperature: -20 °C - 140 °C
capacitive limit detection for food and beverage with hygienic process connection particularly suitable for low level indication at tank bottoms independent of conductivity of media specially for limit ...
Level range: 50 mm - 3,000 mm
Process pressure: 16 bar
Process temperature: -10 °C - 140 °C
... changing media Extremely fast response time < 100 ms for filling processes Simple User Interface mit Display Hygienic alternative to float sensors due to easily sterilisable installation ...
Anderson-Negele | Negele Messtechnik GmbH
Level range: 49 m
Process pressure: 130 psi
Process temperature: 0 °C - 149 °C
... diagnoses level by sensing pressure owing to fluid profundity and its pneumatic force balance grid system consist remains unfazed by drift or temperature impacts. These sensors are specifically ...
Process pressure: 0 bar - 10 bar
Process temperature: 0 °C - 140 °C
The level probe TNS offers numerous features and fully satisfies our and your high standards with regard to quality and hygiene. In connection with a standard evaluation unit, the conductive electrode ...
Level range: 10 m - 200 m
Process pressure: -1 bar - 10 bar
Process temperature: -15 °C - 70 °C
... four different reading scales: US Scale Sensor 240 - 33 Ohm Sensor EU scale 10 - 180 Ohm Sensor Scale 300 - 10 Ohm Sensor Range 4 - 20 mAmp
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining