Process temperature: -40 °C - 150 °C
Process pressure: -1 bar - 40 bar
VIBRATION LEVEL SWITCH - LIQUID FORK The compact and robust solution for safe level monitoring for all types of liquids. Versatile, extensive configuration options, corrosion-resistant ...
UWT GmbH
Process temperature: -40 °C - 1,100 °C
Process pressure: 0.9 bar - 10 bar
Rotonivo® - proven allrounder for point level measurement The Rotonivo® rotary paddle level switch from UWT operates reliably and maintenance-free and offers a compatible solution for ...
UWT GmbH
Process temperature: -40 °C - 80 °C
Process pressure: 0 bar - 0.8 bar
Rotonivo® - proven allrounder for point level measurement The Rotonivo® rotary paddle level switch from UWT operates reliably and maintenance-free and offers a compatible solution for ...
UWT GmbH
Process temperature: -40 °C - 150 °C
Process pressure: 25 bar
... liquid level switches are liquid level sensors for overfill protection that ensure safety as well as simpler, cost-effective maintenance. What Is It? Lidec is a no-moving-parts liquid level ...
Process temperature: -52 °C - 240 °C
Process pressure: -1 bar - 47 bar
Float switch in horizontal design The horizontal float switch can be easily mounted, e.g. on the side of a tank wall. Due to its construction it is suitable for the minimum and maximum limit level ...
JUMO GmbH & Co. KG
Process temperature: -40 °C - 200 °C
Process pressure: -1 bar - 100 bar
Reliable in diverse media Wide variety of process connections For hygienic and industrial applications With marine, WHG and cULus approval Optionally available with Ex certification
Baumer Group
Process temperature: -50 °C - 150 °C
Process pressure: 0 bar - 64 bar
The Type 8111 is a filling level switch for liquids, using a tuning fork as the sensor element. It is designed for industrial use in all areas of process technology and can be used in ...
Process temperature: 0 °C - 300 °C
Process pressure: 25 bar
... aluminium Flange square 92 x 92 mm, 92 mm PCD Switch element Microswitch SPDT with silver contacts Switch rating 250 VAC, 5 A / 30 VDC, 5 A Overall length (tank) 226 mm Safety integrity ...
Trimod'Besta
Process temperature: 0 °C - 250 °C
Process pressure: 0 bar - 250 bar
... Bellow material Perbunan Safety Integrity Level (SIL) SIL 1 (Type AA 01 051: SIL 2) Approvals ABS, BV, ClassNK, DNV-GL, LR, RINA, RMRS Bellow material Silicon Safety Integrity Level ...
Trimod'Besta
Process temperature: -30 °C - 80 °C
Process pressure: 25 bar
... 92 x 92 mm, PCD 92 mm Switch element - Microswitch SPDT with silver contacts Switch rating - 250 VAC, 5 A/30 VDC, 5 A Length of encapsulated cable - 3 m, or as required Cable type - Neoprene (H07 ...
Trimod'Besta
Process pressure: 0 bar - 1 bar
Float switch combined with temperature contact Float switches are switching devices operated by a float moved by fluid. Two switching contacts with temperature contact Switching points: ...
Bosch Rexroth - Industrial Hydraulics
Process temperature: -50 °C - 250 °C
Process pressure: -1 bar - 16 bar
Vibration level switch for solid applications* Point level detection of powders and fine-grained bulk solids * Probe length: 220 mm / 8.7" * Density: <8 g/l / <0.49 lb/ft3 * -50…+250°C ...
KROHNE Messtechnik GmbH
Process temperature: -196 °C - 450 °C
Process pressure: -1 bar - 160 bar
... OPTISWITCH 4000 is a vibration level switch for simple liquid applications. It is a universal and cost-effective device for level detection in small vessels. It detects low or high level ...
KROHNE Messtechnik GmbH
Process temperature: -40 °C - 115 °C
Process pressure: -1 bar - 100 bar
capacitance level switch OPTISWITCH 6700 The OPTISWITCH 6700 is a capacitance level switch for hygienic and general industrial applications requiring ...
KROHNE Messtechnik GmbH
Level switch Medium: oil Max. number of switching points Level: 3 Material pipe: brass Material float: PUR
EUGEN WOERNER GmbH & Co. KG
Level switch Medium: oil Max. number of switching points Level: 3 Material pipe: brass / stainless steel Material float: stainless steel
EUGEN WOERNER GmbH & Co. KG
Level switch Medium: Oil, Ester, Glycole Max. number of switching points Level: 2 Material pipe: Cu Material float: PUR/ stainless steel
EUGEN WOERNER GmbH & Co. KG
Process temperature: -50 °C - 120 °C
Process pressure: 140 bar
... 2 W Product accessories - Liq. level switch accessories Product description - Liquid Level Switch Product group - Switches and thermostats Product ...
DANFOSS Refrigeration & Air Conditioning
... Series Mechanical Level Switches are the most rugged and durable liquid point-level detection products in the industrial marketplace today. ABB's LS Series Mechanical Level ...
ABB Measurement & Analytics
Process temperature: -40 °C - 150 °C
Process pressure: 103, 345 bar
ABB's MS10 Level Switch is the most rugged and durable liquid buoyancy point-level switch product in the industrial marketplace today. The MS10 is a ...
ABB Measurement & Analytics
The LMS200 electric switch is a magnetically actuated double pole double throw switch. When the LMS200 is mounted on a KM26 magnetic liquid level indicator, LS series cage level ...
ABB Measurement & Analytics
Process temperature: -196 °C - 350 °C
Process pressure: 0 bar - 40 bar
... potentialfree. Float switches are also available with multiple switch points. The switching functions always refer to a rising liquid level: Normally open, normally closed or change-over ...
WIKA Alexander Wiegand SE & Co. KG
Process temperature: -30 °C - 150 °C
Applications: - Level measurement of liquids in machine building - Control and monitoring tasks for hydraulic power packs, compressors and cooling systems Special features - Maximum reliability thanks to high-quality ...
WIKA Alexander Wiegand SE & Co. KG
Process temperature: -269 °C - 400 °C
... made using a separate model OSA-S switching amplifier Description The model OLS optoelectronic level switch is used for the detection of limit levels in liquids. This is widely ...
WIKA Alexander Wiegand SE & Co. KG
Process temperature: -40 °C - 150 °C
Process pressure: -1 bar - 64 bar
The VEGASWING 53 is used as a universal level switch in liquids with small dimensions. Independent of the mounting position, it detects reliably with millimetre accuracy the limit level. ...
VEGA Grieshaber KG
Process temperature: -40 °C - 115 °C
Process pressure: -1 bar - 25 bar
The VEGAPOINT 31 is a capacitive level sensor for level detection of fine-grained and powdery bulk solids. Typical applications are overfill and dry run protection. The small sensor can also be used in ...
VEGA Grieshaber KG
Process temperature: -40 °C - 115 °C
Process pressure: -1 bar - 25 bar
The VEGAPOINT 21 is a capacitive level sensor for level detection of water-based liquids. Typical applications are overfill and dry run protection. The small sensor can also be used in thin pipelines. • ...
VEGA Grieshaber KG
Process temperature: -40 °C - 150 °C
Process pressure: 0 bar - 64 bar
Vibrating level switch for liquids For liquids (density: > 0.5 ... 2.5 g/cm³) Application area It detects the limit level reliably and with millimetre accuracy directly at the ...
VEGA TECHNIQUE
Process temperature: -40 °C - 150 °C
Process pressure: 0 bar - 64 bar
... liquid level switch with smallest dimensions. Independent of the mounting position, it detects the limit level reliably and with millimetre accuracy. The device can be used for full or ...
VEGA TECHNIQUE
Process temperature: -50 °C - 250 °C
Process pressure: 0 bar - 64 bar
Vibrating level switch for liquids For liquids (density: > 0.5 ... 2.5 g/cm³) – compact version Application area It detects the limit level reliably and with millimetre accuracy ...
VEGA TECHNIQUE
Process temperature: -20 °C - 50 °C
... echo processing algorithms to identify the sludge interface level using state-of-the-art technology only found in this unit. Why Measure Sludge Level? Sludge blanket level control ...
Process temperature: -50 °C - 150 °C
Process pressure: 100 bar
he Liquiphant FTL51B is specialized for the process industry and developed to be used directly in SIL2 and SIL3 applications. You conduct periodic proof tests according to SIL or WHG mobile with an intuitive wizard. At ...
Endress+Hauser AG
Process temperature: -20 °C - 100 °C
Process pressure: 0 bar - 10 bar
... its travel, meets the built-in Reed switch at the pre-established point, the contact, stimulated by the magnet housed in the float, opens or closes, thus having the possibility of remotely sending a luminous, acoustic ...
Fratelli Giacomello
Process temperature: -20 °C - 120 °C
Process pressure: 0 bar - 10 bar
Electromagnetic level indicators to one or two contacts 1/2" Bsp threaded Connection SPST or SPDT Contacts USE: Made to ensure, with maximum safety, the minimum or minimum and maximum levels of liquids ...
Fratelli Giacomello
Process temperature: -20 °C - 120 °C
Process pressure: 0 bar - 10 bar
Electromagnetic level indicators to one or two contacts 3/4" Bsp threaded Connection SPST or SPDT Contacts USE: Made to ensure, with maximum safety, the minimum or maximum level of liquids in tanks ...
Fratelli Giacomello
Process temperature: -30 °C - 160 °C
... damping of the vibration is detected by the electronics which switch the output relay after a configurable time delay. The vibrating rod level switch is the perfect solution for single ...
Delta Mobrey Limited
Process temperature: -40 °C - 177 °C
Process pressure: 240 bar
... FLT93B BASIC level switch is available with all of the below listed standard features for a very attractive price and with quick delivery as soon as 2 business days ARO. Applications Interface and ...
FCI Fluid Components International
Process temperature: -20 °C - 260 °C
Process pressure: 240 bar
... multiple process sensing and switching requirements. Applications Tank level monitoring Sump level monitoring Mixing level/interface monitoring Specifications For Level/Interface ...
FCI Fluid Components International
Protects sensors from highly corrosive processes in which acids and caustic chemicals condense on the sensor. Description Product Summary Protects sensors from highly corrosive processes in which acids and caustic chemicals condense ...
FCI Fluid Components International
Process temperature: -30 °C - 80 °C
Compact single level vertical mount LS01 Series Liquid Level Sensor used in level control, detection and monitoring. High power switch option, other cables and connectors. Specifications Contact ...
StandexMeder Electronics GmbH
Process temperature: -40 °C - 160 °C
Compact stainless steel single level vertical mount LS02 (S) Series Liquid Level Sensor used in level control, detection and monitoring. High power switch option, other ...
StandexMeder Electronics GmbH
Process temperature: 200 °C
Process pressure: 0 bar - 12 bar
Versatile stainless steel LS05 Series Liquid Level Sensor for single, multi and continuous level control, detection and monitoring capable of high temperature resistance up to 200°C (SS) and pressure ...
StandexMeder Electronics GmbH
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 3.45 bar
The M8000-C miniature liquid level switch has a polypropylene stem and a polypropylene float. Polypropylene is typically suitable for use with acidic liquids such as those found in electroplating and ...
Madison Company
Process temperature: -20 °C - 350 °C
Process pressure: 3, 4.5 MPa
LXT207 float-operated with test device level switches are suitable for controlling liquid level at horizontal mounting. The float equipped with an extended arm moves a couple magnetic mechanism to actuate ...
Golden Mountain Enterprise
Process temperature: -20 °C - 130 °C
New-Flow offers a large variety of products for measurement and control of temperature, pressure, flow, level, and valve. Head Type: Without, or weather proof and explosion proof type available Float Size: (min.) ...
Golden Mountain Enterprise
Process temperature: -20 °C - 130 °C
Process pressure: 10 bar
... measurement and control of temperature, pressure, flow, level, and valve. Housing Model: DIN 43650 and SV-1(universal connector) Connection Type: Sanitary (ISO2852 or DIN32676), PT, NPT, BSP Switch ...
Golden Mountain Enterprise
Liquid Level Photoelectric Sensors The BL series photoelectric liquid level sensors can detect the presence or absence of liquid in transparent pipes measuring 6 to 13 mm in diameter and less than ...
Process temperature: 100, 70, 90 °C
... detecting 1 to 4 levels. It is available with or without an integrated temperature sensor. It can easily control minimum and maximum levels. The device can be used for safe control and monitoring of the ...
Process temperature: 0 °C - 80 °C
... float level switch which comprises of 1, 2, or 3 contacts. For model having a 1 contact, it has an integrated temperature sensor. This is the suitable equipment which offers a simple and an economical ...
Process temperature: 0 °C - 80 °C
... from Galvatek is a float switch with a simple and easy for use design specifically manufactured for liquid operations without covering. This device offer a smooth and cost-effective solution to control and check the liquid ...
Process temperature: -10 °C - 80 °C
Process pressure: 0 bar - 10 bar
Level Switches with Stop Ring Actuation point - LM1 – 1 actuation point NC/NO contact / LM2 – 1 actuation point SPDT contact / LMM1 – 2 actuation points/floats NC/NO contacts Electrical connection - Lead wires L. ...
ELETTROTEC s.r.l.
Process temperature: -10 °C - 80 °C
Process pressure: 0 bar - 10 bar
ctuation point - LM1 – 1 actuation point contact NC/NO / LM2 – 1 actuation point contact SPDT / LMM1 – 2 actuation points NC/NO Mounting - GIA – Flange Ø 92 / GTIA – Thread G2” Switching capacity - LM1/LMM1 – 60W/VA / LM2 – 30W/VA Current ...
ELETTROTEC s.r.l.
Process temperature: -5 °C - 50 °C
Process pressure: 0 bar - 5 bar
PVC Level Switches Materials of constructionAll PVC Actuation points LM1 – 1 actuation point N.C./N.O. contact LM2 – 1 actuation point SPDT contact LMM1 – 2 actuation points N.C./N.O. contacts Mounting GSPA – G3/8” ...
ELETTROTEC s.r.l.
Your suggestions for improvement:
A level switch, or detector monitors levels in open or closed containers.
ApplicationsThese devices are found in every industrial sector. They also are installed with pumps to prevent them from operating dry.
TechnologiesThere are different methods of detecting levels within a container. These include the use of floats, pendulums or rotating paddles. Others employ optical, ultrasound, microwave, capacitive or conductive systems.
How to chooseChoice will depend on the liquid or loose solid material whose level is to be measured. Other factors include temperature, pressure, explosion risk, the structure of the container and other aspects of the operating environment.
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining