Liquids separators
... grease separators or flotation systems is essential. The grease separator is designed for smaller application, such as yachts and offshore platforms, removing fats, oil and grease statically. Automatic ...
Flow: 300 l/h - 500 l/h
The MERLINLiquid cyclone separator is an innovative and patented separation technology that protects liquid analyzers by separating biphasic and particulate-loaded mixtures. The MERLINLiquid ...
... separates sands by extraction, in wastewater treatment of various sector municipal or industrial. It is also called sand classifier or sand washer. Composition of Grit removal: - a decantation hopper - U-section ...
... Carbon steel construction Protects equipment from liquid and particulate entrained in the gas stream Multi-Stage Separation: 316SS vane pack for liquid removal, 316SS mesh pad for trace liquid ...
SOLBERG Filtration
For Coolant and Other Water-based Fluids Removing tramp oil is key to coolant longevity. It's a food for bacteria and emulsifies into the coolant. These conditions lead to coolant breakdown, creating even more problems ...
Zebra Skimmers Corp.
... impurities from sand, B & D has designed the dense medium separator (D.M.S). It also works with the principles of gravity and counter current. A removal percentage of 99% is easily achieved. With low water ...
... to be achieved to remove minerals (ashes) from liquid sugar or water solutions. High quality resins application bringing efficiency on ashes removal, longer cycles, lower consumption of regenerants, ...
E2PS GmbH
Flow: 0.2 m³/h - 5 m³/h
Length: 660 mm - 2,400 mm
Width: 400 mm - 900 mm
The oily water separator is supplied as a compact modular system, with internal piping and wiring. It is ready to use by connecting the suction and discharge lines as well as the central power supply. ...
Flow: 9.6 m³/h - 960 m³/h
The oil and water separator is used to dry compressed air and other industrial gases. The separator ensures the fault-free and efficient operation of compressed-air and gas consumers ...
Flow: 7,200 m³/h
... the compressed air. As condensate consists of 97% water, it is very important to separate it from the 3% oil/impurities, so water can be disposed of through the drain.
Flow: 35 l/min - 1,500 l/min
... ferrous machining applications. These magnetic separators can be used to clean both emulsions as well as neat oil and do not need to be equipped with consumable filter material. Magnetic filter ...
Flow: 3 l/s - 25 l/s
Filtration size: 50 µm - 150 µm
Centrifugal and membrane hydrodynamic Separator Trithon By combining natural settling with centrifugal force, Trithon® traps solid particles. Placed against the selective walls, they directed to the sludge storage compartment. The ...
SIMOP INDUSTRIE
Flow: 6 us gal/min - 132 us gal/min
Polytech magnetic separators have been designed to remove ferrous and non-ferrous solid contaminants from coolants and oils. Magnetic separators can substantially reduce filter cartridge ...
Polytech
... Switch High and High High for Oil and Water Compartments Level Switch Low and Low Low for Oil and Water Compartments Level Controllers for Oil and Water Compartments Oil Line ...
The MARK FOD 21 - 1440 Oil-Water Separator is the perfect system to separate oil from water in your compressed air system. It protects the environment and saves costs! Oil-Water Separators Once ...
... floatables from stormwater runoff over a wide range of flows in a small footprint. Downstream Defender® is an advanced hydrodynamic vortex separator that reliably captures and retains sediments, oil, ...
Hydro International
Flow: 2,000 l/min - 15,000 l/min
... regulations, the residual oil content per litre of water released into drainage systems must not exceed 10 mg/l. The oil content in non treated condensate exceeds 250 mg/l. The “EcoWater” water/oil separators ...
FINI
... use of the continuous vacuum oil and water separator means that when frying, first the oil residue is filtered with the fine filter and then it enters the oil and water ...
Flow: 60 m³/h - 2,160 m³/h
... bottom of separator housing as condensate. The turbulent free zone in the lower part of the filter housing prevents condensate from being picked up and “carried over” into the airstream. To discharge ...
Nitrogenium Innovations Filteration India
... content in the wastewater, for separate disposal or further processing. The separator has a total volume of 4 m³ and can separate up to 8 m³ of waste water per hour. The oil separator ...
BELKI Teknik APS
... grease separators are used to pre-treat kitchen drainage water and, in general, all those drains where oil and grease of animal and plant origin are present. They should be installed near sources ...
Idro group
Width: 12 in - 147 in
Filtration size: 20 µm
Parkson’s Model SRC and SRM Oil/Water Separators offer a reliable, compact, and economical solution to a wide array of oil/water separation applications. The Oil/Water Separators remove free, non-emulsified ...
Flow: 6.8 l/min
Filtration size: 20 µm
... system. This product aims to get skims the tramp oil and coolant mix from the top of the machine sump. In the procedure, the liquids goes slowly in the patented steel coalescing plates, oil droplets as small as 20 microns ...
The design and materials of this series were coordinated especially for operation in NH₃ systems.
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining