Level range: 300 mm - 2,500 mm
Process pressure: 0 bar - 10 bar
Process temperature: -10 °C - 80 °C
Distance - SL1 – 15 mm / SL2 – 10 mm Output - Potentiometric Mounting - FA – Flange Ø 92 / TA – Thread G2” Electrical connection - IP65 EN60529 – PG09 Fluid specific gravity - 0.7 kg/dm3 Fluid viscosity - 150 cSt Size - Min. length ...
Level range: 300 mm - 2,500 mm
Process pressure: 0 bar - 10 bar
Process temperature: -10 °C - 80 °C
Distance - SL1 – 15 mm / SL2 – 10 mm Output - 4-20 mA Mounting - FA – Flange Ø 92 / TA – Thread G2” Signal converter - CVS1 – Connector CVS2 – Box 92 mm × 92 mm Electrical connection - IP65 EN60529 – PG11 Power supply - 24 Vdc ±10% Fluid ...
Electromagnetic Level indicators with a continuous signal Ohm or 4-20mA Accuracy 12 - 24 - 36mm USE: The Levels electromagnetic reed-chain resistors Indicators allow ...
Electromagnetic level indicators with a continuos signal ohm or 4-20 mA Accuracy 12 mm USE: The Levels electromagnetic reed-chain resistors Indicators allow a precise ...
Process temperature: -20 °C - 60 °C
Continuous level indicator certificate N° Tuv 12 Atex 109610 Electromagnetic Level indicators with a continuous signal 4-20mA Accuracy 12 mm USE: The level ...
Process temperature: -40 °C - 105 °C
... switches magnetically actuate as the float moves with the liquid level. Apply DC power and connect the output signal to process meters, programmable controllers, microprocessors or other readout devices. Madison ...
Process pressure: 0 bar - 50 bar
Process temperature: -30 °C - 130 °C
... : Temperature sensor PT1000 • Protection IP65 About The principle of operation is of potentiometric type, based on the gradual shutdown of a chain of resistors and Reed contacts, placed inside the guiding rod, ...
Level range: 3, 6 m
Process temperature: -50 °C - 150 °C
Level Sensor for applications in hazardous locations rugged stainless steel version High repeatability Option: interface measurement and Exi-transducerLevel Sensor in ...
Level range: 0 m - 2 m
Process pressure: 1 bar - 30 bar
Process temperature: -40 °C - 80 °C
The Level Sensors have the following Features: - G3/8" to G2", Flange (round and oval) others on request - PVC- and Silicone-cable - M12-connector - Alu- and ABS-enclosure - Grid: 5 or 10 mm - Overall ...
Level range: 100 mm - 2,000 mm
Process temperature: -10 °C - 80 °C
Resistive electromagnetic gauges supply a continuous linear output signal which, using a suitable instrument, can indicate the level of liquid inside the tank.
Level range: 0 m - 5 m
Process pressure: 0 bar - 6 bar
Process temperature: -30 °C - 105 °C
... the gradual shutdown of a chain of resistors and reed contacts, placed inside the guiding rod, by a magnetic float. The only moving element is the float that moves, for buoyancy, along ...
Level range: 50 mm - 3,000 mm
Process pressure: 10 bar
Process temperature: -40 °C - 125 °C
The magnetic level sensors of the SRF-381 series are based on the action of one or more reed switches located inside the tube where the magnetic float ...
The level CAP80 transducer delivers the measure of the fill level for tanks containing conductive and non-conductive liquids (water, water solutions, food liquids, etc.) and solid materials (flours, granulates, ...
Process temperature: -40 °C - 85 °C
... VISY-Stick Interstitial is an interstices sensor and is used for the quick detection of leakage. It is used in double-walled tanks when the interstices have been filled with a leak-detection fluid. If the level ...
FAFNIR
Level range: 5,000 mm
The Leakage Sensor for Double-Walled TanksVISY-Reed Interstitial sensors detect the presence of liquids in the interstices of double-walled tanks. They function as alarm systems and monitor the level ...
FAFNIR
Level range: 2,000 mm
VISY-Reed Sump sensors detect liquids in the manhole shaft and under the dispenser. They function as alarm systems and monitor the level of the liquid. VISY-Reed sensors are a low-cost ...
FAFNIR
Process temperature: -10 °C - 60 °C
External mount Fast fitting Compact size Easily serviceable Customized wire length Operating temperature – 10 ºC to + 60 ºC
Level range: 0 m - 5.7 m
Process temperature: -40 °C - 85 °C
The level sensor LS10 is developed for liquid level measurement using a float magnet. The level sensor LS10 can be used for any tank ...
Level range: 75 mm
Process temperature: -20 °C - 100 °C
... is a float level sensor with temperature sensor and analog output. This is equipped with 1.5 inch Alu screwed connection with a 2.5 mm or higher resolution. It is offered ...
Engler Steuer-Mess- und Regeltechnik
Process pressure: 16, 3 bar
Process temperature: -20 °C - 120 °C
A float moves along a vertical guide tube. The permanent magnet fixed in the float switches the contacts of a reed contact resistor chain. This resistor chain acts as a voltage divider and provides the ...
Level range: 12, 45 m
Process pressure: -1 bar - 40 bar
Process temperature: -40 °C - 200 °C
... operation and maintenance via P+F Level app The system is based on the reflection of an electromagnetic pulse that is directed on a sensor rod/ cable and reflected by filling material. ...
Level range: 100 mm - 3,000 mm
Process pressure: 350, 700 bar
Process temperature: -40 °C - 110 °C
The level / linear position transducers of the PCSS series are rugged, accurate, without mechanical wear between the measuring probe and the float, they are resistant to shock and vibrations ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining