- Electricity - Electronics >
- Switch and Relay >
- NO/NC contactor
NO/NC contactors
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 40, 63, 25, 32 A
Load voltage: 250, 440 V
The 22 Series comprises a range of modular contactors which include the following features (according to Type): • 17.5, 36, 53.5 mm wide • AC/DC silent coils • 2 or 4 contacts • 35 mm rail (EN 60715) mount
Primary current: 185 A - 2,600 A
The DILM and DILH contactors of the Eaton Moeller series are specifically designed for very high current ranges from 185 A to 2,600 A. With their electronically controlled drives, compact size and long service life, the contactors make ...
Primary current: 20 A
Load voltage: 230 V - 250 V
The ESB20..N installation contactors are used to control single loads up to 20 A and can be operated by AC or DC. These contactors are made for use in household applications as well as in industrial environments. The following benefits ...
ABB
Primary current: 0 A - 30 A
Load voltage: 115 V - 480 V
Our Bulletin 500LG Electrically and Mechanically Held Multi-pole Lighting Contactors feature a modular compact design and easy installation. The contacts switch ballast (fluorescent or HID), tungsten, and general use loads. These contactors ...
For both DC and AC, it has high electrical and mechanical durability and is easy to maintain and inspect. Various contact configurations are available. ▼Features Easy maintenance and inspection. A wide Type of contact configurations ...
Primary current: 25 A
Load voltage: 24 V
Modular Heating Contactor Specifications • Number of Poles 4P • Cable size (mm²) 1.5 - 10mm² Key Features • Single & Three Phase applications • Suitable for control of lamps, heating, air conditioning and motor control • Suitable ...
Primary current: 500 A
Load voltage: 12 V - 500 V
Higher Voltage requirements are in a necessity in today’s world and Albright International are pleased to announce that the first of its high voltage range, is now available. The HV500 is suitable for voltages up to 500V, has a current ...
Primary current: 9 A - 80 A
Load voltage: 24, 220, 440 V
The WEG line of contactors for safety applications (CWBS line 9 A up to 80 A in AC-3), has been developed in accordance with IEC and UL standards, have mechanically linked contacts (IEC / EN 60947-5-1) and mirror contacts (IEC / EN 60947-4-1) ...
Primary current: 60 A
Load voltage: 690 V
GSC1-0904/4-9504/4 Series 4P AC Contactor for remote connection and disconnect circuit, GSC1-0908/4-950/4 Series 4P AC Contactor is used for circuit switching with low inductance, micro inductance or resistance furnace load.
Tianshui 213 Electrical Apparatus Group CO.,LTD.
Thanks to reduced dimensions yet a remarkable power, Logo D.C. contractors are used in electrical vehicles and D.C. handling machinery. Contacts are in silver alloy and double breaking, particularly suitable for heavy duties. They can ...
Primary current: 6 A - 63 A
Load voltage: 24, 48, 110, 230 V
The GYHC series modular contactor uses a new technology platform and applies automated production and testing equipment to create advanced ultra-quiet and long–life contactors. GYHC contactor can be used for remote control: - Lighting, ...
Primary current: 0.2 A - 63 A
Load voltage: 230, 400 V
Installation contactors are built in consumer devices operating in the electrical installations in: dwellings, business premises, hotels, hospitals, shopping centres, sport centres, production halls.
Primary current: 20 A - 110 A
Load voltage: 380, 660 V
ACC1 series AC contactor (hereinafter to be referred as contactor), it mainly applies to the circuit of AC 50Hz/60Hz, and rated insulation voltage 660V. When used in AC-3, and rated operational voltage is 380V, rated current up to 620A, ...
Primary current: 5, 25 A
Load voltage: 12 V - 220 V
Sécheron brings decades of experience designing and manufacturing power contactor solutions for the railway industry and the energy-intensive industries, as well as for renewable energies and e-mobility. Power converter manufacturers, ...
Secheron
Primary current: 9 A
Load voltage: 660 V
Meba magnetic contactor MBK09 is suitable for using in the circuit up to the rated voltage 660 AC 50Hz/60Hz,rated current up to 09A,for frequent starting,controlling the AC motor.The addition of auxiliary contact group to the contactor,combined ...
Primary current: 40 A
Load voltage: 230 V
- Rated operating voltage of power contactors: up to 690V; 50/60Hz - Surge voltage wear resistance: >8000V - Rated operating voltage of the coil: 12/24/36/48/110/230/400 - Electrical wear resistance (number of cycles): ≥1000000 - ...
Elmark
Primary current: 9 A
Load voltage: 24 V
NOARK® Electric Ex9C contactors are intended for various applications including heavy industrial loads. Nine frame sizes allow optimization of electrical parameters and mechanical dimensions. A range of overload relays are available ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining