Open type transformers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Open-core current transformers with compact dimensions for easy installation. This type of transformer is very easy to install and uninstall on compact panels where the ...
Electric power: 0.03 kVA - 0.25 kVA
Primary current: 0.08 A - 1.35 A
Transformers have to be flexible because different situations require different voltages. Murrelektronik's product range offers this flexibility, no matter if it's an isolation transformer, ...
MURRELEKTRONIK
Primary voltage: 720 V
Primary current: 100 A
Secondary current: 5 A
... 5 Ø23 mm 2 m cable compact split core CT Current transformers are used to reduce the primary current to a value suited to the product connected downstream. The Zelec SPCM transformer is an open ...
ZELEC
Primary voltage: 720 V
Primary current: 150 A
Secondary current: 5 A
... 5 Ø23 mm 2 m cable compact split core CT Current transformers are used to reduce the primary current to a value suited to the product connected downstream. The Zelec SPCM transformer is an open ...
ZELEC
Primary voltage: 720 V
Primary current: 5 A
Secondary current: 200 A
... 5 Ø23 mm 2 m cable compact split core CT Current transformers are used to reduce the primary current to a value suited to the product connected downstream. The Zelec SPCM transformer is an open ...
ZELEC
Primary current: 60, 50 A
Secondary current: 1, 5 A
Frequency: 50, 60 Hz
... current transformer. It has the characteristics of small size, light weight, and easy installation. Rated current output is V. Inner hole size 10mm. The flame-retardant plastic housing, protected from moisture, stable ...
CELSA MESSGERATE ESPAÑA S.L.
Primary current: 60 A - 1,200 A
Secondary current: 1, 5 A
Frequency: 50 Hz - 60 Hz
... .5 x 43 mm Primary bar - 2 x 50 x 10 mm / 3 x 40 x 10 mm Round conductor - ⌀ 40 mm Application Split core current transformers convert an alternating current of high value into a proportional, lower one, which is ...
CELSA MESSGERATE ESPAÑA S.L.
Primary current: 100 A - 1,500 A
Secondary current: 1, 5 A
Frequency: 50 Hz - 60 Hz
... Dimensions - 159 x 154.5 x 39 mm Primary bar - 4 x 80 x 10 mm Round conductor - ⌀ 80 mm Application Split core current transformers convert an alternating current of high value into a proportional, lower one, which ...
CELSA MESSGERATE ESPAÑA S.L.
Secondary voltage: 333, 100 mV
Primary current: 5 A - 600 A
Secondary current: 40, 100 mA
Split Core Type Easy Installation CE/ROHS Approved Electrical Specifications • Insulation Voltage : 600V AC • Measurement Range : 20%In~120%In • Accuracy : Class 0.5/Class 1 • Phase Angle : <2° at 50% Rated Current • ...
Secondary voltage: 333, 100 mV
Primary current: 5 A - 1,200 A
Secondary current: 100, 40 mA
Split Core Type RJ12 Terminal Easy Installation CE/ROHS Approved Electrical Specifications • Insulation Voltage : 600V AC • Measurement Range : 20%In~120%In • Accuracy : Class 0.5/Class 1 • Phase Angle : <2° ...
Primary current: 100 A - 600 A
Secondary current: 5, 1 A
Frequency: 50 Hz - 60 Hz
Split Core Type Easy Installation CE/ROHS Approved Electrical Specifications • Insulation Voltage : 600V AC • Measurement Range : 20%In~120%In • Accuracy : Class 0.5/Class 1 • Phase Angle : <2° at 50% Rated Current • ...
Primary voltage: 230 V
Secondary voltage: 115, 230 V
Primary current: 14.2 A - 45.3 A
• Isolating transformers for medical IT systems • Built-in temperature sensor • Shield winding • Insulated mounting brackets • Also available as an energy-efficient variant The transformers of ...
Primary voltage: 0 V - 40,500 V
Secondary voltage: 0 V - 200,000 V
TTH transformers are dry transformers with open wound air insulated MV windings. The low percentage of insulation material with respect to the total weight of the transformer ...
Secondary voltage: 0 V - 3 V
Primary current: 0 A - 80 A
Secondary current: 0 A - 0.8 A
XH-SCT-T10 Split Core Current Transformer CTs Specifications: 1.Diameter:10mm 2.Rated current:0-80A 3.Rated output:mA or mV(0.333V) 4.Insulation Voltage:3KV 5.Rated Frequency:50HZ/60HZ 6.Operating Temperature:-15℃to ...
Jiangyin Spark Electronic Technology Co.,LTD
At JESIVA, we can design and manufacture any type of high frequency transformer under the specific request of the client. We highlight different types of special assemblies: Stacking ...
Transformadores JESIVA,S.L.
Primary voltage: 230 V
Secondary voltage: 115 V
Frequency: 50, 60 Hz
Medical isolation transformers have been manufactured with strengthened isolation. The transformers’ leakage current between the primary and secondary windings is very low. The maximum leakage current ...
Muuntosähkö Oy - Trafox
Primary voltage: 85 V - 265 V
Secondary voltage: 3, 9 V
Primary current: 270 mA - 2,670 mA
Technical Specifications Construction to EN 61 558, EN 60 950 Creeping distance 4 mm min. UL listed materials Insulation material class E Two outputs for connection in parallel or in series 100 % piece inspection Inductance Turns ...
HAHN - Elektrobau
Electric power: 30 W - 30,000 W
Primary voltage: 230, 400 V
Secondary voltage: 48, 12, 24 V
Compliant with standard EN 61558-2-6 • Standard voltages • Other voltages available on request • Electrostatic screen available on request • Ambient temperature 40 °C • Protection rating IP00 • Electrical protection rating I • ...
When a current transformer is used instead of a quadrupole, the current transformer can be placed around a coupling capacitor terminal or around a part of the test object itself. A current transformer ...
Output power kVA: 1 kVA - 600 kVA
Primary voltage: 230, 400 V
Secondary voltage: 230, 400 V
... 2500V ●Supply transformers ●Voltage changing transformers Provide isolation between network installations and sensitive electronic loads. Insulated aluminum or copper windings are wound on a high ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining