Primary current: 45,000 A
VAC: 230, 415 V
VDC: 60 V
C Curve 1 Pole + Neutral VDE Pack Size: 120 Specifications • Neutral Position R • Number of Modules 1 • Short Circuit Capacity 4.00 • Temperature Range °C -5 to 40 °C • Rated Voltage (V) 230/415VAC • Number of Poles 1P+N • ...
Primary current: 10,000 A
VAC: 415, 230 V
VDC: 60 V
B Curve 1 Pole, VDE Specifications • Number of Modules 1 • Short Circuit Capacity 10.00 • Temperature Range °C -5 to 40 °C • Rated Voltage (V) 230/415VAC • Number of Poles 1P • Tripping Curve B • Cable sizes (AWG) 2AWG • ...
Primary current: 16 A - 800 A
VAC: 1,000 V
Product overview STM6E and STM6EL series electronic circuit breakers are applicable for low-voltage power systems of AC 50Hz, rated operating voltage up to 1000V and rated operating current from 16A to 800A. Features ◆Circuit breaker ...
VAC: 35 kV
The three-phase combined over-voltage protector is a novel over-voltage protection equipment, which is mainly used in the power system below 35KV to protect the electrical equipment such as transformer, switch, bus, motor, parallel ...
Primary current: 2,300 A
VAC: 1,800, 3,600 V
VDC: 4,800 V
The UR26-64 is a trip-free DC high-speed current limiting air circuit-breaker, single pole unit, bi-directional, with electromagnetic blowout, direct instantaneous over-current release, natural air-cooling and electrical operating system. ...
Secheron
Primary current: 630 A
VAC: 12 kV
ZW8-12 series vacuum circuit breaker is a H.V. outdoor switch with rated voltage 12kV, tri-phase AC 50Hz, which is mainly used for making and breaking load current, over-current, short-circuit current of rural network, urban network and ...
Primary current: 400 A - 800 A
VAC: 400 V
TECHNICAL DATA: • Rated operating voltage: 415/690V; 50/60Hz • Isolating voltage: 2000V • Surge voltage wear resistance: ≥8000V • Joining terminal: flat (tunnel) screw terminal • Connecting: Ì rigid or flexible conductors Ì front ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining