Tripping current: 30, 6, 10 A
Trigger voltage: 220 V - 415 V
... that allow monitoring of undervoltage and overvoltage, phase sequence and phase failure. Features include (according to Type): • Multifunctional types, providing the flexibility ...
... a fast linear trip is required. All of the overload relays provide unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, ...
Trigger voltage: 190 V - 600 V
... microcontroller-based voltage and phase-sensing circuit constantly monitors the three-phase voltages to detect harmful power line conditions. When a harmful condition is detected, the output relay ...
Trigger voltage: 0 V - 500 V
... electronic monitoring relays! Whether for monitoring voltage, phase sequence, current, insulation, true power, temperature, standstill or fault voltage, you will find ...
Trigger voltage: 24 V
Voltage monitoring relay, to monitor overvoltage and undervoltage values, and the phase sequence in 3-phase supplies, 40 -400 Hz, measuring voltage 400/440 V AC, width ...
Trigger voltage: 690 V
GAMMA Series Phase Loss Monitor for up to 690V nominal voltage This product monitors phase loss, phase sequence, and phase rotation. The under-voltage settings can ...
TELE Haase Steuergeraete GmbH
Trigger voltage: 3 V - 480 V
Voltage monitoring 3-phase with adjustable delay; Phase sequence monitoring; Phase failure monitoring; Asymmetry monitoring; ...
TELE Haase Steuergeraete GmbH
Trigger voltage: 115 V - 400 V
... mains Monitoring relays - GAMMA series Monitoring of phase sequence and phase failure Detection of reverse voltage Connection of neutral wire optional Supply ...
TELE Haase Steuergeraete GmbH
... separated Modbus RTU interface • Voltage monitoring (1- or 3-phase) • Current monitoring • Frequency monitoring • Power factor cos phi • Phase sequence, ...
DOLD
Features • Multifunction measuring relay acc. to EN 60255-1 • Voltage monitoring (1- and 3-phase) • Current monitoring • Frequency monitoring • ...
DOLD
... SLS (safely limited speed), SSM (safe speed monitoring), SSR (safe speed range) and SDI (safe direction) in accordance with EN 61800-5-2. Advantages and customer benefits - Direction of rotation monitoring ...
DOLD
Trigger voltage: 110, 230, 400 V
... it can be used to measure and display the voltage, phase and frequency parameters of the generator and network, as well as its differences. Applications The SynchroMax is a synchronization relay ...
... modules The earth leakage relays of the X...DL3 series are designed for intuitive and automatic detection of leakage currents. The special feature of these relays is that they allow continuous and ...
... Earth Leakage Relay 48x48mm The earth leakage relays of the X...DL3 series are designed for intuitive and automatic detection of leakage currents. The special feature of these relays ...
... Earth Leakage Relay 72x72mm The earth leakage relays of the X...DL3 series are designed for intuitive and automatic detection of leakage currents. The special feature of these relays ...
Monitoring of all static 3-phase parameters: Over / Undervoltage, Sequence, Asymmetry, Frequency. Monitoring of dynamic parameters: df/dt (ROCOF) and Phase angle fault. ...
COMADAN
Tripping current: 1, 3 A
Trigger voltage: 250 V
... is a specialized device for monitoring and protection of 3-phase asynchronous motors, designed for DIN-rail mounting. It monitors phase presence and order, phase line ...
... •Fits every switch cabinet Safe Phase monitoring easy as pie. The DN3PW1 has semiconductor and contact outputs and is suitable for phase voltages up to 400V AC. Even minimal phase ...
... sequence of a threephase power line. If one or more phases disappear, the relay turns off. It is available in two versions: • F 22. The relay turns ON only if the sequence is wrong. • ...
ELETTROMECCANICA CDC s.r.l.
Tripping current: 0.1 A - 5 A
Trigger voltage: 250 V
... range 0.1-5 A - For installation in electrical distributor DIN rail mounting 1 phase Current monitoring AC Current monitoring DC Phase loss monitoring Frequency ...
Trigger voltage: 208 V - 480 V
3-Phase Delta Monitoring Relay, Sequence and Phase Loss, 2 SPDT Relay Outputs, IP20, DIN-rail mounting, Measuring Range 177 to 550Vac, 22.5x83.5x99.5mm ...
CARLO GAVAZZI
Trigger voltage: 415, 220, 380, 400 V
Control relay for monitoring of correct phase sequence, phase break and undervoltage. Connection to 3-phase mains supply with or without neutral. ...
Tripping current: 15, 10 A
Trigger voltage: 115, 230, 400 V
Brodersen's MXP-10 Phase monitoring relay is a relay for monitoring the supply voltage for motors, to secure that the correct phase ...
Trigger voltage: 115 V - 580 V
A relay for monitoring a 3-phase AC power supply with or without Neutral. The relay monitors that all phases are available and in the correct phase ...
Trigger voltage: 64, 133, 230 V
... own three-phase supply and for the output relay to energise, all phases (and neutral) must be present, the phase sequence correct and the phase to neutral ...
Phase monitoring relays Eaton’s D65 phase monitoring relays protect loads from voltage fault conditions. The devices provide protection ...
Trigger voltage: 12 V - 24 V
... PRO relay monitors undervoltage to protect motors and equipment from being damaged by blowouts. The multi timer can sense a maximum voltage of 24 V DC and has a single pole double throw (SPDT) contact ...
Electronic measurement and monitoring relays for measuring input quantities such as current, voltage, phase, cos Phi, temperature and isolation resistance. Our relays ...
• Undervoltage, overvoltage and frequency monitoring in 3(N)AC systems 0…500 V • Various monitoring functions selectable U, f • Asymmetry, phase failure and phase ...
BENDER
Trigger voltage: 208 V - 600 V
Voltage monitoring realy for three-phase system, without neutral, phase loss and incorrect phase sequence, 208...480VAC 50/60Hz • ype of product: Voltage monitoring ...
Trigger voltage: 400 V
... state of the device. The relay immediately breaks if the voltage supply falls below 60% Un. When the device gets supplied from all phases or if one phase is faulty in HRN-54, the relay ...
SEL-321-5 Phase and Ground Distance Relay The SEL-321-5 Relay is designed especially for EHV and HV applications on 50 Hz systems. The relay provides enhanced single-pole ...
Schweitzer Engineering Laboratories
Tripping current: 16 A
Monitoring voltage relay, 3-phase HRN-43, HRN-43N galvanically separated supply AC 230V, AC 400 or AC/DC 24V, memory, adjustable hysteresis and delay, 2 x independent output monitoring ...
ELKO
... Voltage Monitoring Relays which are developed by entes. They are specifically designed for the protection of the motors and networks from undervoltage situations and overvoltage situations. They also ...
Trigger voltage: 208 V - 480 V
The SM 175, which is manufactured by GIC, is a voltage monitoring device that is suitable to use in controlling the sequence of three phases, and its supply voltage. The unit has a compact design, and ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining