- Electricity - Electronics >
- Switch and Relay >
- Plug-in circuit breaker
Plug-in circuit breakers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 0 A - 3,200 A
VAC: 1,150 V
VDC: 1,000 V
A complete range of moulded case circuit-breakers up to 3200 A. All the circuit-breakers, both three-pole and four-pole, are available in the fixed version; sizes T4 and T5 in the plug-in version and T4, T5, T6, and T7 also in the ...
Primary current: 6,000 A
VAC: 230 V
Rating: 16, 6, 32, 20 A
Plug on circuit protection The next generation of residential protection Combining the experience of Schneider Electric with ease of installation and minimised wiring, the Resi9 Protection range is the quickest and simplest way ...
Primary current: 630 A - 1,250 A
VAC: 12 kV
Product Overview: Outdoor high-voltage AC vacuum circuit breakers are primarily used to open and close load current, overload current, and short-circuit current in power systems. They are suitable for the transformation of substations, ...
Primary current: 630 A - 1,250 A
VAC: 12 kV
Product Overview: The deeply integrated pole-mounted circuit breaker integrates vacuum arc extinguishing, voltage sensors, current sensors, and power supply units into the solidified pole columns through a single casting process. Advantages: 1. ...
Primary current: 630 A - 1,250 A
VAC: 12 kV
Product Overview : The deeply integrated fault location type circuit breaker integrates wavelet fault location technology, embedding online fault monitoring and precise positioning functions in a modular form within the FTU (Fault Tree ...
Primary current: 1 A - 63 A
VAC: 230, 400, 415 V
VDC: 80 V
The BSB BG5 hydraulic-magnetic circuit breakers are mainly used in telecom rooms or communication cabinets, serving as isolation, short circuit, and overload protection for cabinets, rooms, or downstream user lines. Features • Poles: ...
Primary current: 7,150, 6,900 A
VAC: 24 kV
System type generator circuit-breaker (GCB) with innovative built-in monitoring The HVS-63S GCB with SF6 interrupting technology for short-circuit currents up to 63 kA and rated currents up to 7,150 A suitable for generators of up to ...
Primary current: 0.5 A - 100 A
Single Pole AC fitted with Plug-in Terminals Curves: • AS (Long Delay) • BS (Medium Delay) • CS (Short Delay) Mounting Options: Metric or Imperial Mounting Approvals: • IEC60947-2 • UL489 • GB140482 • EAC • CE Ratings ...
CBI-electric: low voltage
Primary current: 5 A
VDC: 0 V - 32 V
1-channel thermal device circuit breaker for protecting loads up to 32 V DC in the event of an overload. Fuse type: fast-acting. Can be plugged onto fuse terminal blocks and interfaces for flat plug-in fuse of type C according to standard ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining