- Detection - Measurement >
- Electrical Measurements >
- Portable calibrator
Portable calibrators
Temperature: -10 °C - 50 °C
Noise level: 120 dB
Voltage: 9 V
HD9120 is an acoustic calibrator that, in accordance with the Circular Prot. RU 34143 of 02 December 2011, allows qualified technicians to perform calibrations of sound level meters for comparison with a reference sound ...
Delta OHM
Temperature: -10 °C - 55 °C
Voltage: 115, 120 V
The LCc-II load cell calibration indicator uses microprocessor technology to store ten individual, ten point linearized, load cell calibration curves. This capability allows this device to be used as a calibration force measurement ...
Vishay Nobel Transducers
The load cell tester 1008 allows to test and calibrate a four load cell system in only few minutes, using a simple but practical serial cable connection. The LCT 1008 allows for download of measurement results to a PC via an USB or RS232 ...
Nobel Weighing Systems
Temperature: 40 °C - 375 °C
Voltage: 234 V
Universally applicable and portable Blockcalibrator for immersion-and insertion probes (e.g. Pt 100, Thermocouples) between +40...375°C • Large measuring range +40 ... 375 ° C • 230 VAC power supply • ...
... conjunction with an electronic level and a precision rotary encoder. Once set up, the system is capable of running in automated or manual modes. For more information please visit our website.
Features: * One model for multiple thermocouple types with precision output displayed as mV or °C/°F * Microprocessor assures maximum accuracy to 0.15% of reading over wide ranges * High Accuracy Calibration function simulates ...
Temperature: 30 °C - 650 °C
Voltage: 100 V - 240 V
... diameters ). Check the accuracy of your thermometer/probes quickly and easily in house. Ideal for all sectors who use a number of portable thermometers or in-line indicators / controllers. Also features RS232 output. ...
The SpeedMaster™ is manufactured by Go4B, and is a speed switch calibration and testing device with pulse pilot. It is the only device that accurately tests the calibration of a speed switch, and permits testing of the 10% alarm and 20% ...
The ADB Sensor Tester is a hand held unit perfectly suited for field testing of 4B adjustable depth bearing (ADB) temperature sensors, as it is equipped with an integrated heating block, designed for direct insertion ...
Temperature: 0 °C - 40 °C
SCAL2 Handheld AE Calibrator are designed and developed for the requirements of acoustic emission detector calibration. It can export various standard parametric signals like amplitude, rise time, counts ...
Temperature: 5 °C - 50 °C
Voltage: 220, 110 V
The BL765 is a bench-top humidity generator for calibrating a large workload of probes in the laboratory or on site in the field. The system comprises a humidity and temperature controlled chamber that can house up to six humidity sensors. ...
Balun Technology Co., Ltd
Temperature: 30 °C - 50 °C
Voltage: 110 V - 240 V
... 50℃ in 10 minutes • Target size is 70mm x 70mm • Built-in temperature correction function • Quick and easy operate • Portable and light weight APPLICATION • Ambient temperature compensation for thermal image ...
Balun Technology Co., Ltd
Temperature: 20 °C - 50 °C
Voltage: 110 V - 220 V
... minutes Emissivity > 0.995 Accuracy ±0.05℃ Range 20℃~50℃ Aperture 65 mm diamter With isothermal cavity, the BL672S is a portable blackbody calibration source utilizing a digital indicating temperature ambient 20℃ ...
Balun Technology Co., Ltd
MDJB series torque wrench tester is a test instrument used to calibrate various torque wrenches. The instrument adopts the single-chip control technology and is composed of a precision torque sensor and a force-bearing bracket. Equivalent ...
MDJB series torque wrench tester is a test instrument used to calibrate various torque wrenches. The instrument adopts the single-chip control technology and is composed of a precision torque sensor and a force-bearing bracket. Equivalent ...
Temperature: 40 °C - 375 °C
The LHC 75 dry block temperature calibrator is a compact and lightweight device, suitable for all conditions and applications, covering different types of industries. The LHC 75 calibrator is the most ...
Leyro Instruments
Temperature: -35 °C - 165 °C
The Leyro Portable dry block temperature calibrator suitable for temperature calibrations, between -35ºC ... 165ºC *, offers a versatile solution for calibrating thermocouples and ...
Leyro Instruments
Temperature: 40 °C - 450 °C
The LHC 400 Basic dry block temperature calibrator is a lightweight and compact device, suitable for all conditions and applications, covering different types of industries. The LHC 400 calibrator is ...
Leyro Instruments
The CL 325 multi-functional process calibrator from Tecpel is equipped with a beeper warning when output is open (mA) or short (mV,V). It features K, J, E, T Thermocouple in °C and °F, easy key-pad operation, and easy ...
The CL-420B is a handheld, programmable calibrator for measurement and signal output. It's great for measuring tiny currents and voltage signals, and it can power sensors while checking their returned current signals. Mainly ...
The TECPEL DSL-336A Sound Level Calibrator is ideally designed to provide an extremely high quality performance and functionality. The level calibrator is mainly constructed to meet the users' needs and ...
The stage micrometer from Opto in the form of a microscope slide is required for the calibration of microscopes. - Glass scale 50 mm in 0.1 mm and 0.01 mm - Calibration of measurement software The stage micrometer is also available ...
Voltage: 24, 30 V
Temperature: -5 °C - 60 °C
... FDA 21 CFR part 11 compliant Rotronic HW4 software Since its launch, the Rotronic HygroGen has defined the standard for portable humidity and temperature calibration. Hundreds of users worldwide have identified that ...
Temperature: 10 °C - 50 °C
Voltage: 0 V - 5 V
Based on Edgetech Instruments field proven chilled mirror sensor technology A completely self-sufficient and portable humidity calibration system Temperature and relative humidity controlled independently ...
Voltage: 0 V - 1,000 V
ULTRA PORTABLE CALIBRATOR • Full function, ultra portable calibrator • AC/DC Voltage output to 1000V • AC/DC current to 10A (500A using EA002 Coil) ...
TRANSMILLE
Voltage: 0 V - 20 V
... The 33XXA Series multiproduct calibrators are modular versions of the class leading 3000A Series Calibrators. Designed to reduce cost, the 33XXA Series feature 0 – 20V DC output as standard with a wide ...
TRANSMILLE
Temperature: 25 °C - 200 °C
Voltage: 0 V - 1,000 V
... 9000A series range of multiproduct calibrators offers the widest workload of any calibration system presently available. The 9000A series provides all of the functionality of the 3000A series multiproduct ...
TRANSMILLE
Temperature: -10 °C - 50 °C
Pressure: -1 bar - 4,200 bar
Voltage: 0 V - 15 V
AOIP
Temperature: -270 °C - 2,310 °C
Pressure: 0 bar - 1,000 bar
Voltage: 100 mV - 50,000 mV
CALYS 1000 is a field documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, ...
AOIP
Temperature: -250 °C - 2,310 °C
Pressure: 0 bar - 1,000 bar
Voltage: 100 mV - 50,000 mV
CALYS 100 is a field precision documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, ...
AOIP
Pressure: 0 bar - 40 bar
Voltage: 4, 5 V
... object being tested with the provided quick-coupling Staubli® “T” fitting. The operator can adjust the leak flow through a manual needle valve or enable/disable the simulated leak by simply pressing a button on the LCD ...
Noise level: 94 dB - 114 dB
... sound level calibrator. Also for calibration and verification of microphones in audio technology, you need a sound level calibrator, which is designed to produce several sound pressure levels at a fixed ...
Temperature: -24 °C - 140 °C
Voltage: 12 V
Portable calibrators have a quick response time and good accuracy and stability, which means that they can calibrate temperature sensors both in a lab and on the field in a short time. Liquid calibrators ...
GIUSSANI SRL
Temperature: -100 °C - 40 °C
Calsys -100/40 offers easy to use portable low temperature calibrator with temperature range from -100 to 40°C. It is a highly stable standard furnace for calibrating RTD. This calibrator ...
TEMPSENS
Temperature: 50 °C - 650 °C
CALsys 650 offers easy to use portable temperature calibrator with medium temperature range from 50 to 650°C. It is a highly stable standard furnace for calibrating thermocouples / RTD. This calibrator ...
TEMPSENS
Temperature: -80 °C - 50 °C
Calsys -80/50 offers easy to use liquid temperature calibrator with high temperature range from -80 to 50°C. It is a highly stable standard furnace for calibrating thermocouples / RTD. It provide superior thermal environment ...
TEMPSENS
Voltage: 9 V
* Frequency :125 Hz/250 Hz/500 Hz/1K Hz * Level : 94/104/114 dB * Power Supply : 9 V ( 006P, MIN1604 ) x 1 Pc
Temperature: -45 °C - 85 °C
The VC-01 Handheld Calibrator is a low cost reference accelerometer device that allows the user to quickly check the response of accelerometers at a known fixed frequency and level. Ideal for use in the ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining