Probes
SDi oxygen probes For heat treatment processes ZrO2 measuring tube for accurately measuring oxygen partial pressure and carbon concentration Reliable and robust Different lengths Optional ceramic protection tube Delivered ...
... Novapress®, ceramic The SP2200-H sample probes are used for continuous sampling of gases from highly dust-loaded, high-temperature or humid processes. They can be back-purged with a closed sample gas outlet. Gas sample ...
M&C TechGroup Germany GmbH
... the sample probe. Gas sample probe type SP2500‑H/C/I/BB with external ceramic filter type S‑2K150, filter porosity: 2 µm, sample tube or pre‑filter retractable through the sample probe ...
M&C TechGroup Germany GmbH
... sample probe. Gas sample probe type SP2500‑H/C/I/BB‑F with external ceramic filter type S‑2K150, filter porosity: 2 µm, sample tube or pre‑filter retractable through the sample probe ...
M&C TechGroup Germany GmbH
... Temperature 400 Degree Probe PTM600-FG flue gas detector can optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 400 ℃. 400mm & ...
This stainless steel liquid probe features a rigid stem with a flat tip ideal for high accuracy temperature measurement in a wide variety of laboratory applications. Response time is less than 4 seconds. With a measuring ...
GESA TERMOMETROS
This hand held liquid probe features a rigid, stainless steel stem with a flat tip. The probe is suitable for high accuracy temperature measurement in a wide variety of laboratory applications when ...
GESA TERMOMETROS
... fast response probes with reduced tip are suitable for semi-solids and liquids incliding soft rubber or plastic. With a measuring range going from -75 to 250ºC and a 1m long straight or coiled cable, these type K ...
GESA TERMOMETROS
TECPEL DP100 Oscilloscope 100MHz differential probe Product ID: DP-100 Differential Probe Model: DP-100 ( 6.5KVp-p / 100MHz ) The DP-100 Differential probe provides a safety means ...
... input signal to a low voltage ground referenced signal for display on any Oscilloscope. The product FET input differential probe provides a safe means of measuring circuits with floating potentials up to 1000 V ( DC+ ...
These are LF-190E, LF-210E and LF-250 by Tecpel Co is an Oscilloscope probe which is designed for wide range of applications. For LF-190E, it has a 60 MHz rating and comprises of item 10 and item 1. The item 1 has a rating ...
Type 50GI is a sound intensity probe for direct connection to signal analyzers or data acqusition devices with IEPE inputs. The probe includes a pair of phase-matched prepolarized precision microphones ...
G.R.A.S. Sound & Vibration
X1 Oscilloscope Probe Body. Cable type : Coaxial. Color : Black / yellow. Standard length : 120 cm (47 ''). Detail : Attenuation X1. Input impedance 45 pF. Bandwidth 25 MHz. Rise time 14 ns.
ELECTRO PJP
... current traveling through the probe window area. For ease and convenience of performing conducted measurements, all of our current probes utilize the split type clamp-on design. Small and lightweight, ...
A.H. Systems
... range of 10 KHz to 152 MHz the BCP-611 monitoring current probe is a great measurement tool for MIL-STD, CISPR and many automotive specifications. The 1V/A flat response of this current probe makes it ...
A.H. Systems
... measured without making direct contact with the source conductor or metallic surface by means of clamp-on current probes. The BCP-614 Current Probe is designed to permit field intensity meters, spectrum ...
A.H. Systems
... Description Ultrasonic probe for non destructive test (NDT) on concrete foundation poles. SUF52FRF model is an ultrasonic high efficiency active transducer which can be used both as emitting (TX) and as receiver (RX) ...
M.A.E. S.r.l.
THERMAL CONDUCTIVITY PROBE FOR SOIL , LENGHT 120 CM. Description CTS120 is a probe, for measures in the soil (lenght = 120 cm), that offers the possibility to perform a practical and fast measurement ...
M.A.E. S.r.l.
THERMAL CONDUCTIVITY PROBE ON SAMPLES, LENGHT 45 CM Description CTS45 is a probe for measuring the conductivity in laboratory on samples , length: 45 cm, that offers the possibility to perform a practical ...
M.A.E. S.r.l.
... heated filter probe has an integrated filter chamber that accepts a glass fibre filter cartridge or a stainless steel sintered filter. Two stages of filtration can be achieved using a 20 micron (or 10 micron) SS sintered ...
The CleanAir single point heated EMC gas sampling probe is available with a 1/4″ or 3/8″ stainless steel heating jacket, a 1″ OD stainless steel sheath and a type K thermocouple. The probe is available ...
Used to locate buried plastic Water Pipes, Gas Pipes and any other non-magnetic utility, Sondes are self-contained transmitters that are used with our cable and pipe locators. Sondes are typically attached to a Flexrod, pushed along ...
Radiodetection
Compact in-situ probe Using heated ZrO2 sensor for wet O2 analysis up to 600°C flue gas temperature With optional special heated solid electrolyte sensor for combustibles measurement Basic-Equipment ...
An advanced Langmuir probe for plasma diagnostics Routine monitoring of the I-V plasma characteristic by the Hiden ESPion probe gives direct information relating to plasma stability and reproducibility. ...
Twin Element Ultrasonic Probe designed for high-temperature, in-service thickness measurements and corrosion surveys across oil and gas, refining, energy and process sectors. Great wear resistance allows for use on hot ...
... eventually wear down. The gauge will automatically “Zero” the probe to compensate for wear (until there is excessive wear when the probe should be replaced). The gauge will indicate when the probe ...
... crystal probes are for use with the gauge in Multiple-Echo mode to read through and ignore coatings. These have one piezo-ceramic crystal. This crystal both sends and receives the ultrasound energy. The S2C single crystal ...
... or metric sizes with various insertion lengths. Signal Group offer a large range of sample probes for various applications. These can be Heated or Insulated. Probe material include Stainless Steel, Monel, ...
• Three current ranges: 30A, 300A and 3000A. • Two output sensitivities (300mV and 1V), versatile for measuring instruments. • Input protection up to 600V. • Suitable for any electncal system. • Wide bandwidth, low phase shift. • ...
• Three current ranges: 60A, 600A and 6000A. • Two output sensitivities (600mV and 1V), versatile for measu ring instruments. • Input protection up to 600V. • Suitable for any electrical system. • Wide bandwidth, Iow phase shift. • ...
DIFFERENTIAL PROBE P9000 Easily Connect to Hioki Memory HiCorders and HiLoggers for High Voltage Testing Overview • - Compact probe for CAT III 1000V environments • - Wave mode: Observe instantaneous ...
HIOKI EUROPE GmbH
Probes to Measure Illuminance or Irradiance There are different optical quantities and a range of different measurement geometries that require the use of dedicated probes. As a full line manufacturer, ...
GL Optic
... Both types of probe differ in the type of built-in counter and thus in the measuring range. If dose rates above 10 mSv/h are not to be expected, the probe 6150AD-18/E with its more sensitive detector ...
AUTOMESS GmbH Automation und Messtechnik
The calibratable Teletector Probe 6150AD-t/E is a portable probe which, in conjunction with a dose rate meter 6150AD, is used to measure photon radiation (gamma and X-rays) in the quantity of H*(10). ...
AUTOMESS GmbH Automation und Messtechnik
... scintillator probe are the large energy range and high sensitivity. The scintillator probe is therefore particularly suitable for fast and accurate measurements of small radiation levels, down to the ...
AUTOMESS GmbH Automation und Messtechnik
... • Suitable for connection to any oscilloscope • High accuracy general purpose H-field probe • Converts to 'closed magnetic circuit' current probe
The PI-07P probe works in the frequency range 100 MHz – 60 GHz, covering most of the test requirements of MIL STD-464, RTCA-DO-160, FAA HIRF Rule & Advisory Circular 20-158, Boeing, Airbus and automotive EMC GM and ...
EMC Test Design, LLC
EE872 Modular 4 in 1 probe for CO2, humidity, temperature and pressure The EE872 reliably measures CO2 concentration up to 5 % (50 000 ppm) in agriculture, life stock barns, hatchers, incubators, green houses or outdoors. ...
E+E ELEKTRONIK
The ROYALPROBE™ HFX is the world’s first liquid NMR probe switchable between single tune and dual tune mode on the High Frequency coil without compromising the NMR performance. The ROYALPROBE™ HFX operating in single ...
Jeol
... PC • Dynamic energy discriminator button • Telescopic pole with H*(10) ambient gamma dose equivalent rate measurement probe • Gamma dose rate measurement up to 10 Sv/h (1000 rem/h) • Energy-compensated Geiger Mueller ...
... optical probes contain a diffusor for scattering incident light. Behind the diffusor is the entrance facet of the optical fiber, with which light is coupled into the spectrometer. Applications For general applications ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining