- Detection - Measurement >
- Temperature and Humidity Measurements >
- Pyrometer black body calibration source
Pyrometer black body calibration sources
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Temperature: -10 °C - 1,600 °C
... comprehensive range of six calibration sources lets you calibrate radiation thermometers across a temperature range of -10 °C to 1600 °C (15 °F to 2900 °F). As Landcal blackbody sources ...
Temperature: 38 °C
... accurate determination of human body temperature has led to the development of a high accuracy blackbody source for 38 °C (100.4 °F) calibration of infrared thermometers/pyrometers ...
Temperature: 38 °C
... to the development of a high accuracy blackbody source for 38 °C (100.4 °F) calibration of infrared thermometers/pyrometers and thermal imagers. The blackbody heat source ...
Temperature: -20 °C - 350 °C
... aperture, the ME30 liquid bath blackbody is designed for calibrating thermal imaging cameras and Infrared Radiation Thermometers (Pyrometers) at a temperature range from -20 °C to 350 °C. The cavity is ...
HEITRONICS Infrarot Messtechnik GmbH
Temperature: -20 °C - 110 °C
... aperture, the SW40 liquid bath blackbody is designed for calibrating thermal imaging cameras and Infrared Radiation Thermometers (Pyrometers). The cavity is heated with high uniformity by the surrounding ...
HEITRONICS Infrarot Messtechnik GmbH
Temperature: 100 °C
... blackbody that has a fixed set-point temperature. 100 °C is the standard radiator temperature. •Portable blackbody for calibration on site •Optional temperatures on request
HEITRONICS Infrarot Messtechnik GmbH
Temperature: 420 °C - 1,085 °C
IR-R0A is a national standard class fixed point black body furnace. Fixed point cell exchange is easy with detachable crucibles: In point to Cu point. - Good plateau is achieved by improvement of ...
CHINO CORPORATION
Temperature: 50 °C - 1,450 °C
... Metrology, are large opening blackbody furnaces for calibration of radiation thermometers, and a high temperature comparison blackbody furnace uses a standard radiation thermometer for comparison calibration.NRLM ...
CHINO CORPORATION
Temperature: 100 °C - 3,000 °C
... blackbody furnaces cover the temperature range of 100 to 3000°C by 3 kinds of blackbody furnace and calibrate radiation thermometers accurately.
CHINO CORPORATION
Temperature: 35 °C - 150 °C
Low Temperature Calibration Sources with Fixed Temperature Options from 35 to 150°C Advanced Energy's Mikron IRC calibration sources are small and easy to use. They’re ...
Temperature: 5 °C - 50 °C
CALsys 37BB calibration source is a accurate & stable Portable blackbody specially designed for increasing accurac y of thermal imager based human body temperature monitoring. The emissivity ...
Accurate Sensors Technologies Pvt Ltd
Temperature: 50 °C - 350 °C
The 975 is a low cost fast Greybody source offering a cost effective solution for the calibration and testing of infrared thermometers from 50°C to 350°C. It is ideal when the high accuracy ...
AOIP
Temperature: 20 °C - 45 °C
The 988 is a low cost Blackbody source introduced to meet customer requirements for a simple, cost effective but high accuracy calibrator for the calibration of thermal imagers and infrared ...
AOIP
Temperature: 30 °C - 550 °C
... Blackbody calibration source allows for calibration of non-contact infrared thermometers from 30°C to 550°C. It is suitable for use as a primary radiation source ...
AOIP
Temperature: 500 °C - 1,700 °C
... application in pyrometer industry, non contact sensor calibration. The unique feature of this black body furnace is large temperature control black body ...
Temperature: 300 °C - 1,200 °C
... easy to use black body calibrator with high temperature range from 300 to 1200°C. It is a highly stable standard furnace for calibrating pyrometer and non contact sensor. ...
Temperature: 50 °C - 1,000 °C
... 1000BB calibration source is a highly stable standard Black Body Furnace for calibrating noncontact IR thermometer for the wide temperature range of ...
... blackbody calibration sources pyrotherm works as a source for customer-specific applications and for the calibration of pyrometers and infrared cameras. ...
The OL 480 serves as an accurate, variable temperature (100 to 1200°C) blackbody calibration standard. It is extremely useful for calibrating infrared radiometric and spectroradiometeric measurement systems. The OL 480 ...
The unit is a Black body calibration source manufactured by Nagman, applicable for pyrometers. It has temperature range of 20°C and above, with ambient ...
Temperature: 300 °C - 1,700 °C
Process Sensors blackbody calibration source Model BBS 1700 features a high emissivity of +0.99 and a 1” ( 25mm) aperture. Delivering a temperature range from 300°C to 1700°C, simply adjust the set point ...
Temperature: 20 °C - 50 °C
CN-37 blackbody: Thermal cameras’ reference source for real-time fever detection With the Covid-19 pandemic spreading around the globe, HGH developed a new Blackbody technology to answer IR thermography ...
Temperature: -20 °C - 350 °C
... Accurate Blackbody Calibration Source with integrated Controller for Calibration of Infrared Radiation Pyrometer, Thermometer and Thermal Imaging ...
Heitronics
Temperature: 5 °C - 80 °C
The infrared thermometer Comparator provides a stable black body temperature source and is an inexpensive way of checking infrared hand held thermometers ...
Temperature: 50 °C - 1,600 °C
H-Series Pyrometer Blackbody Calibration Source has the characteristics of wide temperature range, large caliber, high stability, and can be set for cyclic temperature control. It ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining