- Electricity - Electronics >
- Cable, Connector, Enclosure >
- Round electrical cable
Round electrical cables
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Nominal voltage: 250 V - 600 V
Temperature: -30 °C - 80 °C
For inspection robots in coolant channels or nuclear tanks, these composite cables are the best choice. It has 1 screened strand of 4 conductors 0.75mm², 2 conductors 2.5mm², 16 conductors 0.25mm² and 9 conductors 0.34mm². ...
Nominal voltage: 500, 300 V
Temperature: -40 °C - 70 °C
Cross-section: 0.22, 0.5, 1.5, 0.75, 1 mm²
In this chapter you will find multi-pair compensating and extension cables with PVC insulation for a temperature range up to 70°C.
SAB BROECKSKES GMBH & Co. KG
Temperature: 250 °C
Cross-section: 1, 0.22, 0.5 mm²
The PFA insulated extension cables for thermocouples are used for temperatures up to 250°C. They are available with galvanized as well as with a stainless steel wire armouring.
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 1,500, 500, 350 V
Temperature: -30 °C - 70 °C
Cross-section: 0.14 mm² - 1.5 mm²
PVC data cable LiYY with reference to DIN 47100 Marking for LiYY 03053225: SAB BRÖCKSKES · D-VIERSEN · LIYY 32x0,25mm²CE LiYY Cable - The PVC/PVC data cable is a flexible data cable ...
SAB BROECKSKES GMBH & Co. KG
Temperature: -40 °C - 85 °C
... • Any application (e.g WLL, GPS, LMR, WLAN, WISP, WiMax, SCADA, mobile antennas) requiring an easily routed, low loss RF cable
Times Microwave Systems
Nominal voltage: 300, 1,000 V
Temperature: -40 °C - 80 °C
Cross-section: 0.08 mm² - 240 mm²
Nominal voltage: 600 V
Temperature: 80 °C
Cross-section: 0.14 mm² - 95 mm²
Galvanized steel round conductor Principally indicated for capture mesh conductors and down conductor connections in lightning protection systems. Characteristics • Economical. • 125m & Ø8mm Coils (Other ...
Temperature: -20 °C - 70 °C
Length: 100 m
... material : PVC PHYSICAL DATA : • Copper Content : kg/km : 19,1 • Cable Weight : kg/km : 44,1 • Min bending radius x 1/n : mm : 35/70 • Max.Tensile Strength : N : 150 ELECTRICAL DATA : • ...
Cavel
Temperature: -40 °C - 80 °C
Length: 100, 500 m
... material : PVC PHYSICAL DATA : • Copper Content : kg/km : 12,6 • Cable Weight : kg/km : 43,9 • Min bending radius x 1/n : mm : 35/70 • Max.Tensile Strength : N : 120 ELECTRICAL DATA : • ...
Cavel
Temperature: -40 °C - 80 °C
Length: 500 m
... material : PE PHYSICAL DATA : • Copper Content : kg/km : 83,1 • Cable Weight : kg/km : 188,4 • Min bending radius x 1/n : mm : 200 • Max.Tensile Strength : N : 800 ELECTRICAL DATA : • Impedance ...
Cavel
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm² - 50 mm²
power, control and connecting cable in electrical facilities for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in ...
CAE GROUPE
Nominal voltage: 300 V
Temperature: -30 °C - 70 °C
Length: 500 m
CAE GROUPE
Nominal voltage: 1,000 V
Temperature: -25 °C - 60 °C
The RVFV cables are the power cables for use on industrial sites and the upright columns of buildings. • conform to RoHS • resistant to aliphatic hydrocarbons conductor material bare copper strand
CAE GROUPE
Nominal voltage: 2, 3 kV
Temperature: -50 °C - 180 °C
Cross-section: 10 mm² - 300 mm²
... mm² out of single insulated silicone extruded cables 1,8/3 kV with solderless crimped contact areas and additional insulation crimp Technical data Electrical conductor: • Round ...
Druseidt
Nominal voltage: 3, 2 kV
Temperature: -50 °C - 180 °C
Cross-section: 70 mm² - 300 mm²
... mm² out of single insulated silicone extruded cables 1,8/3 kV with solderless crimped contact areas and additional insulation crimp Technical data Electrical conductor: • Round ...
Druseidt
Nominal voltage: 3, 2 kV
Temperature: -50 °C - 180 °C
Cross-section: 10 mm² - 300 mm²
... mm² out of single insulated silicone extruded cables 1,8/3 kV with cable shoe-shaped contact areas and additional insulation crimp Technical data Electrical conductor: • Round ...
Druseidt
Nominal voltage: 300, 500 V
Temperature: -40 °C - 70 °C
... control cables in CNC machine tools, engraving machines, wood working machines, steel production and other automation equipment in all kinds of machines. Intended for the place with serious electrical ...
Zhaolong Interconnect
Temperature: -40 °C - 175 °C
Cross-section: 0.13 mm² - 1.5 mm²
Multi-core automotive cables for safe and reliable driver assistance With LEONI Adascar® we offer a comprehensive product portfolio of multi-core shielded and unshielded cables. Divided into the areas ...
LEONI AG
Nominal voltage: 350 V
Temperature: -40 °C - 70 °C
Cross-section: 0.14 mm² - 0.34 mm²
... at 30 MHz, approx. 250 Ohm/km Minimum bending radius - flexible 7.5x Outer-Ø fixed 4x Outer-Ø Copper wire bare, extra finely stranded Wire structure: 0.14 mm²: approx. 18 x 0.1 mm 0.25 mm²: ...
HELUKABEL
Nominal voltage: 15 kV
Temperature: 20 °C - 90 °C
Cross-section: 35 mm² - 300 mm²
The XLPE 15V aluminum conductor insulated cable features a compact round conductor typically made of aluminum strands, blocked or not, and comes with a cross-linked polyethylene (XLPE) cover in black ...
Henan Tong-Da Cable Company
Nominal voltage: 200, 250, 320 kV
Temperature: -30 °C - 60 °C
... experienced and reliable manufacturer and solution provider of submarine power cables. It forms about 4,000 kilometers of medium voltage (hereafter called MV) power cables annual output and becomes a ...
ZTT
Nominal voltage: 500, 300 V
Temperature: -50 °C - 700 °C
Cross-section: 0.5 mm² - 50 mm²
Benefits • Suitable for areas where the installation temperature and ambient temperature is very high • Good electrical conductivity due to nickel strand also at high temperatures Application • Heating modules, ...
Lapp France
Nominal voltage: 1,000 V
Temperature: -25 °C - 260 °C
... It entails cross-border recognition of the approvals for our cable products in accordance with European / international standards. Multi-core cables (optional shielded) in flat and round ...
Nominal voltage: 15 V
Temperature: -65 °C - 200 °C
... shielded twisted pair cables in a low-profile design that’s 30% smaller, reducing their weight by as much as 50% compared to standard oval cables. If you compare our design side by side with alternative ...
W. L. Gore & Associates, Inc.
Nominal voltage: 54 kV - 500 kV
Temperature: 90 °C
Cross-section: 240 mm² - 2,500 mm²
XDRCU–ALT Single–core Cable for 500/290 (550) kV with Copper wire screen and Aluminium laminated sheath Construction * Copper conductor, round stranded or segmented, optionally ...
Brugg Kabel AG
Axon’ has designed tailor-made composite cables for 50 years. The company has integrated the manufacture of conductors (silver plated copper, tin plated copper, nickel plated copper,etc), the assembly, taping, shielding, ...
Axon Cable
... service life of wire; Smooth wire surface and compact structure, can reduce the cold water droplets, ice and snow for gathering around the wire surface, effectively reducing the probability of wire ...
Temperature: 70 °C
Cross-section: 0.75, 1, 1.5 mm²
... Series, manufactured by Channel Well Technology, is a power cable designed for the transmission of electrical power. It has an operating temperature of 70℃ and a bare copper conductor. This power cable ...
Nominal voltage: 600 V
Temperature: 105 °C
● Solid or strands, tinned or bare copper conductor 30-10AWG;UL 1569 Electronic wires Electronic wires Technical Data UL 1569 Technical data ● PVC insulation ,comply with ROHS environmental standard; ● Uniform insulation thickness ...
M12 PROFINET patch cord D-coded M12 male molded to RJ-45 Application Areas: Industry Electrical Values Cat.5e SF/UTP 100 Mbit Plug A Site M12 D-coded male shielded, molded Plug B ...
AIXONTEC
Temperature: -55 °C - 200 °C
Coaxial cable RG Applications: Radio communications equipment and other similar high-frequency transmission technology using electronic devices Technical Data: •Jacket: FEP •Shielded: silver plated copper •Insulation: ...
Jiangsu Silver&Tin Thread Hi-Temp Wire And Cables
Temperature: -10 °C - 105 °C
ANSI PVC Insulated Thermocouple Cable with Plug and Socket Cable Description PVC insulated flat pair construction Conductors laid flat PVC insulated with overall PVC sheath All round ...
Temperature: -30 °C - 70 °C
Coaxial Cable Rg174, 50ohms Coaxial Cable, Rg174 with Connectors manufacturer / supplier in China, offering High Quality RF Coaxial Cable Rg174, Twin Rg174 Coaxial Cable, ...
Jiangsu Elesun Cable Co., Ltd.
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining